This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it17951 - Convention (Subpart B), Gross Ton 29870 - Dead Weight, Metric Ton 35879 - Displacement, Metric Ton 10748 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 5
16 February 2022PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7395248
3 July 2019Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6724062
6 December 2018Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6589703
2 September 2016COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5989431
24 May 2016Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5880288
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 May 2016Resolved
0715 - Fire Detection - Fire detection and alarm systems shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed crew members test smoke detectors over the shipboard incinerator, and between fuel purifiers No. 01 & 02. Neither of the smoke detectors tested activated or alarmed when tested. 74 SOLAS (am) II-2/14 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 24 May 2016
Resolution: Crew changed smoke detector testing bottle and were able to test smoke detectors satisfactorily.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.