MAURY USCG vessel records
← All vessels

MAVERICK

MAVERICK is a 2005 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in March 2026, along with 3 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 9 March 2026.

Built
2005
Last inspected
9 March 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDJ3884
738733
Flag
UNITED STATES
Maury page id
psix-738733

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 14.0 ft × 6.7 ft
Registered tonnagegross 28 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARKLEY'S MARINA INC · BALTIMORE, MD, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portQUEENSTOWN, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 8 April 2005
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

9 March 2026 Internal Structural Exam · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8329341
11 February 2026 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8309309
24 November 2025 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8273370
9 December 2024 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8045189
27 November 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7829920
20 March 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7653880
28 November 2022 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7601070
21 October 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7336954
20 April 2021 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7200273
18 August 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7036501
9 April 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6935852
10 February 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6904748
26 March 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6656067
12 April 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6390848
23 August 2016 DAPI Audit · Internal Structural Exam · Drydock Exam · Plan Review "T" Boat · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6102386

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 August 2020 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b). Deficiency: 01 portable extinguisher was observed low and requiring refill. 46CFR181.500(a)
Action required: 10 - Deficiency Rectified
Resolved 18 August 2020
Resolution: New 3-A:40-B:C portable extinguisher purchased as replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 August 2020 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through-hull fitting below the deepest load waterline, such as a lazarette. Deficiency: Bilge high water level indicator float in lazarette broke free of mount.
Action required: 10 - Deficiency Rectified
Resolved 18 August 2020
Resolution: Lazarette bilge high water level indicator float remounted.
Engineering › Steering Gear System › Hydraulic Hose
Issued 23 August 2016 Resolved
Replace DAYCO hose with SAE J1942 approved hose and reroute out of electrical conduit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 12 April 2018
Resolution: Verified hydraulic lines were SAE J1942 approved and separated from waterlines.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.