CLIPPER LEGACY is a 2005 tank ship. The Coast Guard has recorded 19 inspections since 2005, most recently in May 2012, along with 6 deficiencies and 1 operational control.

Records from 2005 to 2012. Most recent: inspection, 10 May 2012.

Built
2005
Last inspected
10 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9307437 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
739051
Flag
BAHAMAS, THE
—
Maury page id
psix-739051

Inspections, by type

…with no type recorded6
Years with a record 5 calendar years (2005–2012)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6522 - Convention (Subpart B), Gross Ton
3220 - Convention (Subpart B), Net Ton
10097 - Dead Weight, Ton
13758 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

10 May 2012 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4307390
6 January 2012 Ballast Water Examination · MARPOL Annex VI Survey · ISPS II Exam · MARPOL Annex I Examination · COC-CHEM Renew · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4217777
27 July 2008 COC-TVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3280435
9 June 2008 Joint Vessel Security Verification (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3227003
21 March 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3168844
8 February 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3143995
17 December 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3116904
13 December 2007 MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3114761
21 May 2007 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2936569
11 May 2007 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2927762
26 April 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2916809
23 April 2007 MARPOL Annex I Examination · MARPOL Annex II Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · COC-CHEM Renew · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2913443
20 October 2006 Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2802419
20 October 2006 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2802420
20 October 2006 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2802422
29 June 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2408517
9 March 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2306416
8 March 2005 MARPOL Annex I Examination · ISPS I Exam · MARPOL Annex V Examination · Ballast Water Examination · COC-CHEM Renew
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2305719
8 March 2005 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2626335

Deficiency record · 6

Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 17 December 2007 Resolved
Have class attest to proper operation and condition of shaft seal. Vsl reportd that they were taking on water during voyage from NY to PEV. Class survey report is required prior to vsl departure.
Action required: 705 - Other - as specified
Due 17 December 2007
Resolved 18 December 2007
Documentation › Logs/Records › Enhanced Survey Report File
Issued 17 December 2007 Resolved
CG Form 2692 is required for Marine Casualty while departing NY.
Action required: 705 - Other - as specified
Due 17 December 2007
Resolved 17 December 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 December 2007 Resolved
USCG Inspector noted test valve located after OWS three way valve and before OWS discharge valve. This valve is not addressed on vessels OWS installation diagram, and was fabricated by vessels crew. Vessels class society is to address this installed valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 January 2008
Resolved 8 February 2008
Resolution: Received class report that shows valve has been removed.
Documentation › Certificates/Documents › IOPP Certificate
Issued 23 April 2007 Resolved
IOPP showing throughput as 1 M3hr, while OWS shows 1.5 M3hr, prior to return to US after going foreign have correct throughput listed on IOPP.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 May 2007
Resolution: Def Cleared
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 April 2007 Resolved
Three-way valve for oily water separator sticking and allowing water to pass by when above 15+ PPM, prove proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2007
Resolved 23 April 2007
Resolution: Crew had to clean out the three-way valve and was latter tested satisfactory.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 23 April 2007 Resolved
Prior to departure submit a update to show correct departure date for Rotterdam as 3/21/2007.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2007
Resolution: ANOA updated.

Ownership record