CRYSTAL COAST LADY
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG East District (CGD-E) · Other hulls named CRYSTAL COAST LADY
CRYSTAL COAST LADY is a 2005 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2004, most recently in April 2026, along with 57 deficiencies and 1 operational control.
Records from 2004 to 2026. Most recent: inspection, 22 April 2026.
- Built
- 2005
- Last inspected
- 22 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 57 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1168207
WDP4092
739385
Flag
UNITED STATES
368039120, 368351240
Maury page id
psix-739385
Inspections, by type
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 178 / net 63
BuilderMID-CITY STEEL FABRICATING · LA CROSSE, WI, UNITED STATES · built 2005
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBEAUFORT, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
178 - Convention (Subpart B), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
178 - Convention (Subpart B), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP4092MMSI 368351240 · active · compulsorily equipped · granted 1 February 2024, expires 1 February 2034
WDK2805MMSI 368039120 · active · compulsorily equipped · granted 17 May 2018, expires 17 May 2028 · licensed under a name not among this hull’s recorded names (not shown)
WDI3643MMSI 367690420 · expired · compulsorily equipped · granted 28 August 2015, cancelled 7 March 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDC5573MMSI 367043180 · expired · compulsorily equipped · granted 19 May 2005, cancelled 25 July 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 35
22 April 2026
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8332045
14 January 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8301605
14 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8111181
5 February 2025
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8077159
23 October 2024
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8022937
22 April 2024
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7892022
19 March 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7881477
12 October 2023
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7806721
15 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7559761
6 May 2022
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7445761
27 October 2021
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7340871
16 July 2020
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6965625
13 April 2020
Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6938619
21 February 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6913029
16 April 2019
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6697186
1 April 2019
Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6696774
15 October 2018
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6560116
23 March 2018
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6397862
9 June 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6170253
7 September 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5994633
24 November 2015
Examination of Repairs · Administrative Inspection · Drydock Exam · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5769774
27 August 2015
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5228519
4 May 2012
Annual Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4307673
1 August 2011
Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4097450
9 September 2010
Administrative Inspection · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3845898
6 March 2009
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3428665
17 November 2008
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3366070
29 July 2008
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3283898
9 May 2007
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2925758
17 April 2007
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2909343
26 July 2006
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2721720
17 August 2005
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2465687
6 July 2005
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2417237
23 May 2005
Initial Certification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2360569
3 August 2004
Inclining Experiment · Construction Oversight · Hull Examination
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2317124
Deficiency record · 57
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 February 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 October 2023
Resolved
"Each item of survival craft equipment must be of good
quality, and efficient for the purpose it is intended to
serve." Inspectors observed life float to have photodegradation,
rips, holes, and tears that would impact
the serviceability of the float. Vessel is restricted to
1 mile from shore until replacement life float is on
board.
46 CFR 180.175
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 October 2023
Resolved
"On a vessel of more than 19.8 meters (65 feet) in
length, the minimum capacity of the fire pump must be
189 liters (50 gallons) per minute at a pressure of not
less than 414 kPa (60 psi) at the pump outlet." The
Inspectors witnessed the pressure gauge of the fire pump
at 20 psi.
46 CFR 181.300
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 October 2023
Resolved
"The use of plastic tie wraps must be limited to
bundling or retention of multiple cable installations,
and not used as a means of support." Inspectors noticed
electrical wires being supported in the engine room with
plastic ties.
46 CFR 183.340
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 October 2023
Resolved
"A hatch cover must: have securing devices; and be
attached to the hatch frame or coaming by hinges,
captive chains, or other devices of substantial strength
to prevent its loss." Inspectors noticed that the hatch
cover for the lazarette did not have any securing
devices to prevent its loss
46 CFR 179.360
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 October 2023
Resolved
"Placards containing instructions for the donning and
use of the life jackets aboard the vessel must be posted
in conspicuous areas that are regularly accessible and
visible to the crew and passengers." Inspectors noticed
that there was no life jacket donning placards posted
onboard the vessel or placards posted to indicate the
location and number of life jackets.
46 CFR 185.516
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 12 October 2023
Resolved
"Except on a vessel limited to daytime operations, the
compass must be illuminated." Compass light not
operable.
46 CFR 184.402
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023
Resolved
"The general construction of the vessel must be such as
to minimize fire hazards insofar as it is reasonable and
practicable" Wire penetration between engine room and
deck of the electrical
46 CFR 177.405 (a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 October 2023
Resolved
"Through hull fittings and shutoff valves must be
metallic." Several through hull fittings in engine room
and tank void are made of PVC pipe. Must fix prior to
next credit dry dock.
46 CFR 182.720 (d) (3)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 12 October 2023
Resolved
"Except for engine exhausts, each inlet or discharge
pipe that penetrates the hull below a line drawn
parallel to and at least 6 inches above the deepest load
waterline must have means to prevent water from entering
the vessel if the pipe fractures or otherwise fails."
Several through hull fittings in engine room and tank
void do not have a valve. Fix prior to next credit dry
dock.
46 CFR 179.350 (c)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 September 2022
Resolved
"Service use of distress signals shall be limited to a period of 3 years from the date of manufacture." MI noted expired flares.
46 CFR 180.30
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 September 2022
Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. Nozzle on fire hose of main deck was seized and unable to switch between streams.
46 CFR 181.320(d)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2022
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Switchboard door in aft electrical closet on main the deck is unable to latch closed.
46 CFR 183.330(b)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Light switch in galley behind sink is uncovered.
46 CFR 183.200(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2022
Resolved
Conduct sea trials for newly installed generator
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 October 2021
Resolved
Life float light must be a floating waterlight approved under approval series 161.010. Approval requires light mounted in bracket in accordance with manufacturer. One light not mounted in bracket.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 October 2021
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EBIRP hydrostatic release not marked. Install and mark new hydrostatic release.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 27 October 2021
Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly, using the integrated test circuit
and output indicator, to determine that it is operative. Vessel's logbook showed no record of EPIRB tests.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 July 2020
Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. EPIRB is not currently registered with NOAA.
47 CFR 80.1061(f)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 16 July 2020
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release is currently expired.
46 CFR 185.740
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 July 2020
Resolved
At least one ring life buoy must be fitted with a lifeline. Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Ring buoy life line is light in color and not UV resistant.
46 CFR 180.70(c)(6)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 July 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit was not IAW with 160.041 and had expired items.
46 CFR 184.710
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 July 2020
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. Vessel did not have EAP information displayed for crew members.
46 CFR 16.401
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2020
Resolved
Cable and wire for power and lighting circuits must: Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable. AC system on upper deck is currently wired with ROMEX wire which is not marine grade. The wires run from the AC unit down to the lower deck into a distribution panel.
46 CFR 180.137
46 CFR 183.340(d)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 July 2020
Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. Life floats were not properly seperated.
46 CFR 180.137
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2020
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. A dead end wire was located on the starboard bow main deck.
46 CFR 183.340(g)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 July 2020
Resolved
A power-driven vessel underway shall exhibit: A masthead light forward. Masthead light was inoperable.
33 CFR 83.23(a)(i)
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 October 2018
Resolved
ONLY INDIVIDUALS THAT ARE U.S. CITIZENS MAY HOLD OFFICER POSITIONS ON U.S. FLAGGED VESSELS. THE VESSEL'S CAPTAIN WAS A NON-U.S. CITIZEN, HOLDING A CREDENTIAL ISSUED BY THE U.K. M.C.A. VESSEL IS TO BE OPERATED BY A U.S. CITIZEN AS MASTER AND 75% OF THE CREW SHALL BE CITIZENS OF THE U.S. 46CFR10.221(a)(1) 701C
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2018
Resolved
AN FCC SHIP STATION LICENSE IS REQUIRED WHEN A RADIOTELEPHONE AND EPIRB ARE INSTALLED. THE VESSEL DID NOT HAVE AN FCC SHIP STATION LICENSE. 47CFR80.13 701C
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 15 October 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 October 2018
Resolved
PROVISIONS MUST BE MADE TO ALLOW FOR THE CLOSING OF ALL VENTILLAION AND EXHAUST OPENINGS IN A SPACE PROTECTED BY A FIXED GAS FIRE EXTINGUISHING SYSTEM.PROPER OPERATION OF ENGINE ROOM VENTILLATION CLOSURES COULD NOT BE VERIFIED BY THE ATTENDING MI. 46CFR182.465(h) 701C
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 October 2018
Resolved
LIFE FLOATS SHALL BE STOWED IN A FLOAT FREE ARRANGEMENT, WITH EACH LIFE FLOAT BEING SEPARATED BY SPACERS AND CONTAINING A LIFELINE, PENDANTS, TWO PADDLES, A PAINTER, AND A LIGHT. THE LIFE FLOATS WERE STOWED BY A STRAP HOOKED TO A HAMAR HYDROSTATIC RELEASE UNIT, WITH A BRIDLE OF LINE OVER TO OF THEM; THE LIFE FLOATS WERE ALSO NOT CONNECTED TO THE VESSEL VIA A PAINTER LINE, DID NOT HAVE THE REQUIRED PADDLES ATTACHED, AND THERE WAS ONLY 01 LIGHT LOCATED WITH THE 04 LIFE FLOATS ON BOARD THE VESSEL. 46CFR180.130(a)(2); 46CFR180.130(a)(9); 46CFR180.137(f); 46CFR180.175(d) 701C
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2018
Resolved
FUEL SHUTOFF VALVES SHALL HAVE HANDLES. THE VESSEL'S FUEL SHUTOFF VALVE DID NOT HAVE A HANDLE. 46CFR182.455(b)(4) 701C
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2018
Resolved
ALL PASSENGER VESSELS SHALL HAVE A PASSENGER SAFETY ORIENTATION. THE VESSEL DID NOT HAVE A PASSENGER SAFETY ORIENTATION TO INFORM PASSENGERS OF THE REQUIRED ITEMS. 46CFR185.506 701C
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 October 2018
Resolved
A DEVICE MUST BE PROVIDED TO AUTOMATICALLY SHUT DOWN POWER VENTILATION SERVING THE PROTECTED SPACE & ENGINES THAT DRAW INTAKE FROM THE PROTECTED SPACE PRIOR TO THE RELEASE OF EXTINGUISHING AGENT. THE POWER VENTILATION DID NOT SHUT DOWN AUTOMATICALLY PRIOR TO AGENT RELEASE. 46CFR181.405(b)(10) 701C
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 October 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 15 October 2018
Resolved
EACH SHIP OF 40' OR GREATER SHALL HAVE A WASTE MANAGEMENT PLAN. THE VESSEL DID NOT HAVE A WASTE MANAGEMENT PLAN. 33CFR151.57 16C
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 October 2018
Resolved
DISTRESS SIGNALS SHALL BE STOWED IN A WATERTIGHT CONTAINER. ORANGE SMOKE SIGNALS WERE NOT STOWED IN A WATERTIGHT CONTAINER. 46CFR180.68(e)(1) 16C
Documentation › Certificates/Documents › Stability Letter
Issued 4 May 2012
Resolved
Vessel restricted to carrying a maximum of 89 passengers, 8 crew, with no more than 21 pax on upper deck on a partially protected route. On a protected route: max 121 pax, 8 crew, with no more than 48 pax on upper deck. Vessel requested voluntary reduction to meet new stability regs.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 May 2012
Resolved
Provide current FCC safety certificate.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 August 2011
Resolved
Prove inspection and maintenance of fixed fire extinguisher and portable fire extinguishers. CG-835 No-Sail has been given for this item.
Fire Fighting › Fire Hoses › Condition
Issued 1 August 2011
Resolved
Replace fire hose on upper deck. CG-835 No-Sail has been given for this item.
Engineering › Bilge Water Management System › Not Operational
Issued 1 August 2011
Resolved
Prove bilge suction from every compartment. CG-835 No-Sail has been given for this item.
Personnel › Training › Fire Fighting Basic
Issued 1 August 2011
Resolved
Conduct safety drills in the presence of a Coast Guard Marine Inspector. CG-835 No-Sail has been given for this item.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 July 2011
Resolved
Vessel was issued CG 835 for overdue Annual Exam. Exam overdue since 16JUL11.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 26 July 2006
Resolved
Provide proof of pre-arranged chemical testing for Serious Marine Incidents.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 July 2006
Resolved
Place EAP phone number in visible location for crew members.
Operations/Management › Passenger Operations › Safety Orientation
Issued 23 July 2006
Resolved
Post placard/stencil maximum passenger count permitted on the upper deck.
Navigation › Piloting/Steering › Marine Charts
Issued 23 May 2005
Resolved
Provide up-to-date charts and nautical publications in accordance with 46 CFR 184.420.
Lifesaving › Lifefloat › Quantity
Issued 23 May 2005
Resolved
Remove or maintain excess lifesaving equipment.
Stability › Intact Righting Energy › General
Issued 23 May 2005
Resolved
Post stability letter at operating station.
Documentation › Logs/Records › Logbook (official)
Issued 23 May 2005
Resolved
Provide logs and records in accordance with 46 CFR 185.502-.530.
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 May 2005
Resolved
Calibrate GPS to give accurate compass readings.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 23 May 2005
Resolved
Provide specification sheet for exhaust system proving it meets through-hull and structural fire protection requirements.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 23 May 2005
Resolved
Provide documentation proving CG approval of fixed fire extinguishing system in engine room.
Fire Fighting › Structural - B Class Divisions › Main Galleys
Issued 23 May 2005
Resolved
Provide specification sheets for galley equipment.