← All vessels
GENCO WARRIOR
GENCO WARRIOR is a 2005 freight ship. The Coast Guard has recorded 25 inspections since 2005, most recently in April 2024, along with 9 deficiencies and 8 operational controls, 1 with no removal date recorded.
Records from 2005 to 2024. Most recent: inspection, 17 April 2024.
- Built
- 2005
- Last inspected
- 17 April 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9316153 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7LU3
739437
Flag
MARSHALL ISLANDS
—
Maury page id
psix-739437
Inspections, by type
…with no type recorded9
Years with a record
11 calendar years (2005–2024)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it31069 - Convention (Subpart B), Gross Ton
18171 - Convention (Subpart B), Net Ton
55435 - Dead Weight, Metric Ton
64449 - Displacement, Metric Ton
18171 - Convention (Subpart B), Net Ton
55435 - Dead Weight, Metric Ton
64449 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
17 April 2024
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7896677
29 March 2024
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7886866
7 February 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7633673
7 February 2023
COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7633680
20 May 2022
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7455114
1 October 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7324799
14 May 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6941275
23 April 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6943020
4 December 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6317403
12 June 2017
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6173630
16 August 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination · COE-Dockside
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5974092
16 June 2012
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4348991
16 June 2012
Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4350551
24 January 2012
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4230781
30 May 2008
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3222351
29 May 2008
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3221576
11 November 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3096513
9 November 2007
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3098136
5 November 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3093450
12 September 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3051025
10 September 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3054325
26 June 2007
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2975361
22 June 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2970739
13 March 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2309136
9 March 2005
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2305811
Deficiency record · 9
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 March 2024
Resolved
CABLES AND WIRING SHALL BE INSTALLED AND SUPPORTED IN SUCH A MANNER AS TO AVOID CHAFIING AND OTHER DAMAGE.
PSCO OBSERVED MULTIPLE BATTERY WIRES MELTING TOGETHER ON BRIDGE EMERGENCY BATTERIES LOCATED IN BRIDGE BATTERY ROOM.
74SOLAS(04) II-1/45.5.5
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 29 March 2024
Resolved
EACH INCINERATOR SUBJECT TO THIS PARAGRAPH SHALL BE APPROVED BY THE ADMINISTRATION TAKING INTO ACCOUNT THE STANDARD SPECIFICATION FOR SHIPBOARD INCINERATORS DEVELOPED BY THE ORGANIZATION.
INCINERATORS WALLS ARE TO BE PROTECTED WITH INSULATED FIRE BRICKS/REFRACTORY AND COOLING SYSTEM.
MEPC.76(40)3.4.
REFRACTORY MATERIAL USED TO PATCH REFRACTORY WAS FOUND FALLING AWAY FROM ANCHOR HOOKS.
MARPOL Annex VI: REG. 16.6.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2020
Resolved
The machinery and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed fuel oil leaking on #4 cylinder on the main engine.
74 SOLAS (04) II-1/26.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 May 2020
Resolved
The machinery and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed fuel oil leak on the #2 auxiliary engine.
74 SOLAS (04) II-1/26.1
Lifesaving › Lifeboat Equipment › Food Ration
Issued 4 December 2017
Resolved
Each lifeboat is required to have a food ration totalling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate,kept in air tight packages; Both lifeboats have food a ration totalling 4,188 kJ per person. Several packages were noted to be no longer air tight.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 17 August 2016
Resolved
PSCO observed a modification from the purifier in way of fuel oil settling tank. 74SOLAS(AM) II-II/4.2.2
Engineering › Pressure Vessel › Piping
Issued 17 August 2016
Resolved
Crew installed epoxy repair on raw water cooling line to MDE intercooler. 74SOLAS (AM) II-1/26
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 16 June 2012
Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. The vessel lost propulsion while departing the AKRR Freight and Coal facility in Seward, AK. Deficiency is to be rectified to the satisfaction of Class with accompanying survey
Cite: SOLAS 74 (04' Amended) Ch. II-I, Regulation 26.3
Lifesaving › Rocket Parachute Flares › General
Issued 11 November 2007
Resolved
Vessel had 12 Hand Flares on bridge, not 12 Rocket Parachute Flares. Vessel is to acquire proper flares prior to departure from port. Rectify to the satisfaction of Coast Guard Inspector.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.