Records from 2005 to 2008. Most recent: inspection, 24 October 2008.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 6 April 2006
Resolved
33U.S.C.1321(j)(5)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge
33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization (OSRO) or provide an OSRO contract for the remote Guam COTP zone
Due 6 May 2006
Resolved 15 January 2009
Resolution: NTVRP plan #03910 deactivated due to no response from plan preparer/plan holder. If plan holder wants Interim Operating Authorization, plan holder must resubmit NTVRP for review and approval.
Fire Fighting › Means of Escape › Blocked
Issued 27 March 2006
Resolved
Clear and remove equipment stored in escape trunk in engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2006
Resolution: equipment stored in escape trunk in engine room removed.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 27 March 2006
No resolution recorded
Provide bracket for extinguisher in galley.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 27 May 2006 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 27 March 2006
No resolution recorded
Conduct maintenance for latches to vegetabule and meat room. Ensure easy operation from the inside.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 27 May 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 27 March 2006
No resolution recorded
Provide proper rubber matting for electrical switch board in engine room.
Action required: 15 - Rectify deficiencies by next port
Due 27 May 2006 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 27 March 2006
No resolution recorded
Provide light covers for lights in control room and engine room.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 27 May 2006 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 27 March 2006
No resolution recorded
Provide adequate illumination / lighting in engine room.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 27 May 2006 — due date passed with no resolution recorded
Documentation › Markings/Placards › Garbage Placard
Issued 27 March 2006
No resolution recorded
Provide MARPOL garbage placard in galley.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 28 May 2006 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Fire
Issued 27 March 2006
Resolved
Fire drill communications and response very slow.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2006
Resolution: Fire drill communications and response times impoved.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 27 March 2006
No resolution recorded
Starboard bow mooring line needs to be replaced, due to multiple splices and wear.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 27 May 2006 — due date passed with no resolution recorded
Lifesaving › Lifebuoys › Serviceable
Issued 17 March 2005
Resolved
Replace/attatch Retro Reflective Tape on ring Lifebuoys.
Action required: 15 - Rectify deficiencies by next port
Resolved 11 May 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 March 2005
Resolved
Where waterlights are provided for ringbuoys; ensure the lights are properly attached to ring buoy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2005
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 17 March 2005
Resolved
Conduct and log both pre-arrival and pre-departure equipent tests.
Action required: 15 - Rectify deficiencies by next port
Resolved 11 May 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 March 2005
No resolution recorded
Install machinery guard for galley stove ventilation fan. As per ILO
Action required: 15 - Rectify deficiencies by next port
Fire Fighting › Means of Escape › Escape Route Signs
Issued 17 March 2005
Resolved
Properly mark escape routes and escape doors in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2005
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 17 March 2005
Resolved
Provide Steering Gear Instructions at Bridge and Steering Compartment as per SOLAS 74 Reg 19-2(c)(i).
Action required: 15 - Rectify deficiencies by next port
Resolved 11 May 2005
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 17 March 2005
No resolution recorded
Post a Manuvering Fact Sheet on Navigation Bridge.
Action required: 15 - Rectify deficiencies by next port
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 17 March 2005
Resolved
Provide on board a valid International Tonnage Certificate
Action required: 15 - Rectify deficiencies by next port
Resolved 11 May 2005
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 17 March 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2005
Engineering › Steering Gear System › Starter
Issued 17 March 2005
Resolved
Provide a statement from Classification Society accepting current arrangement for local operation of steering gear. Currently only bridge can switch control to steering compartment. Or provide accurate instructions to crew to locally operate steering gear.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 April 2005