MAURY USCG vessel records
← All vessels

VANTAGE KEY

VANTAGE KEY is a 2004 freight ship. The Coast Guard has recorded 3 inspections in 2017, along with 2 deficiencies — 2 with no resolution recorded — and 1 operational control.

Records in 2017. Most recent: inspection, 12 May 2017.

Built
2004
Last inspected
12 May 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 May 2017
…with no type recorded2
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9293870
739596
Flag
LIBERIA
Maury page id
psix-739596

Documentation record

Tonnage as PSIX records it17951 - Convention (Subpart B), Gross Ton
10748 - Convention (Subpart B), Net Ton
29870 - Dead Weight, Ton
35880 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

12 May 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6140533
11 May 2017 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6144576
10 May 2017 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6143345

Deficiency record · 2

Engineering › Freshwater Generation System › Piping
Issued 12 May 2017 No resolution recorded
1499-Other-Aux machinery- The machinery boilers, & other piping systems & fittings shall be of a design & construction adequate for the service for which they are intended. Leaking pipe in the engine room, pipe leading from the main sea chest to the fresh water generator pump is wasted & leaking. 74 Solas (04) II-1/26
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 July 2017 — due date passed with no resolution recorded
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 12 May 2017 No resolution recorded
0715-Firefighting detection- Suitable instructions & components spares for testing & maintenance shall be provided. Detectors shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. Vessel had no means to test heat activated fire alarms. 74 Solas (04) II-2/7.2.2 FSS code 9.2.5.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign

Ownership record