Records from 2005 to 2010. Most recent: inspection, 29 September 2010.
Inspection history · 22
29 September 2010
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3860631
29 July 2009
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3549752
5 March 2009
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3426921
7 October 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3340058
26 September 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3332995
5 August 2008
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3289589
9 December 2007
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3109929
20 September 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3062046
27 July 2007
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 3009193
14 May 2007
PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2930058
17 February 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2873550
14 February 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2872128
10 August 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2743389
13 May 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2648210
17 February 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2587264
17 October 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2516009
13 August 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2461714
13 August 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2463088
29 May 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2373017
24 March 2005
Ballast Water Examination · PII Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2318918
11 March 2005
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2310281
10 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2307622
Accommodation/Occupational Safety › Ventilation › General
Issued 29 July 2009
No resolution recorded
0950 - Vent water line appears to have pin hole leaks by main electric feeder panel. This poses a potential loss of power or personal hazard. Rectify to satisfaction of administration
Action required: 705 - Other - as specified
Due 17 October 2009 — due date passed with no resolution recorded
Resolution: Recieved class report clearing deficiency
Lifesaving › Lifeboat › Hull
Issued 29 July 2009
Resolved
0610 - Port life boat hull and helm cover appear to be cracked. This could lead to the life boat not being operationally ready. Rectify to satisfaction of administration.
Action required: 705 - Other - as specified
Due 17 October 2009
Resolved 17 November 2009
Resolution: Recieved class report to clear deficiency
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 29 July 2009
Resolved
0710 - Door frames to purifier room, engine store room, and tunnel spaces are cracked. This is a potential fire boundary breach. Rectify to satisfaction of administration.
Action required: 705 - Other - as specified
Due 17 October 2009
Resolved 17 October 2009
Resolution: Recieved class report to clear deficiency
Operations/Management › Drills/Instruction › Fire
Issued 29 July 2009
Resolved
2020 - Crew failed first fire drill which was located in emergency control room. Chief engineer requested fixed co2 in accommodation. Master then requested foam to be used in ECR.
Due 29 July 2009
Resolved 29 July 2009
Resolution: Crew conducted and satisfactorily completed second fire drill.
Operations/Management › Navigation Safety › Persons Allowed in Pilothouse/Navigation Bridge
Issued 29 July 2009
Resolved
0955 - Pilot ladder bottom two rubber steps are broken on port side. Possible hazard to pilot embarkation. Rectify to satisfaction of administration.
Action required: 705 - Other - as specified
Due 17 October 2009
Resolved 17 October 2009
Resolution: Recieved class report to clear deficiency
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 5 August 2008
Resolved
2510; The [name withheld] is using a non-approved Ballast Water Handling Log Form and he has not been documenting the sediments in the tanks or the removal of sediment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2008
Resolved 5 August 2008
Resolution: Discussed items with the Captain and [name withheld] out the specific requirements as per 33 CFR for the Mandatory documentation of Ballast Water.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 5 August 2008
Resolved
1705; The SOPEP and Non-Tank VRP were missing the local USCG contact numbers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2008
Resolved 5 August 2008
Resolution: Gave the Master copies of local numbers.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 5 August 2008
Resolved
2120: The crew is not following the Garbage Plan they stated that they only burn oil rags, however various other items were found in the ash. The [name withheld] has not been recording the burning of trash in the garbage log. Fluorescent lights were found broken and in bags in the Engine Work Shop. The electrician is required to collect and maintain them for shore disposal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2008
Resolved 5 August 2008
Resolution: Discussed items with the Master, [name withheld], Chief Engineer and Second Engineer who is responsible for the collection of garbage and is in charge of the incinerator.
Fire Fighting › International Shore Connection › Bolts
Issued 5 August 2008
Resolved
0799; The international shore connection located at the gangway port side was missing two of the four bolts and washers. The bolts that were there were missing their washers and were rusted to a point that the nut could not be turned.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2008
Resolved 5 August 2008
Resolution: The crew replaced all of the bolts, washers and nuts.
Electrical › Electric Generation Source (emergency) › Generator
Issued 5 August 2008
Resolved
1499; The canvas ducting for the air intake has holes in it and the hydraulic piping near the engine is leaking.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 September 2008
Resolved 26 September 2008
Resolution: Repairs have been made to the satisfaction of the attending Classification Society Representative.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 5 August 2008
Resolved
0730: The ship has a small portable compressor for recharging their SCBA air bottles. It is located in a locker near the ship's office which does not have a direct flow of fresh air. The crew needs to connect a air hose to the system and they need to clean and inspect the system as per the manufacturers requirements.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 September 2008
Resolved 26 September 2008
Resolution: Repairs have been made to the satisfaction of the attending Classification Society Representative.
Lifesaving › Lifeboat › Safety Belt
Issued 5 August 2008
Resolved
0610: The port lifeboat seat belts have been replaced and hand sewn. Some lagging must be placed around the exhaust for the crew's protection. The crew needs to add 30m of buoyant line to the quoits. They presently have nylon line attached to them. Additional reflective tape must be added to the outboard side of the lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 August 2008
Resolved 26 September 2008
Resolution: Repairs have been made to the satisfaction of the attending Classification Society Representative.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 13 August 2005
Resolved
The generators No1 and No2 circuit breaker tripped and failed to institute re-connection to main switchboard after power failure. Repair to the satisfaction of Class Society prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2005
Resolution: The circuit fuse and under frequency module transducer was replaced to satisfaction of DNV.