ARCADIA

ARCADIA is a 2005 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in March 2026, along with 17 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: operational control imposed, 21 March 2026.

Built
2005
Last inspected
17 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9226906
739751
Flag
BERMUDA
Maury page id
psix-739751

Documentation record

Tonnage as PSIX records it84342 - Convention (Subpart B), Gross Ton
84342 - Regulatory (Subpart C or D), Gross Ton
46086 - Convention (Subpart B), Net Ton
10123 - Dead Weight, Ton
44934 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

17 March 2026 COC-CVE Annual · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8327487
15 March 2026 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8326972
14 March 2026 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8324234
29 January 2025 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8071689
14 September 2024 COC-CVE Annual · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8001876
16 January 2024 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7849863
8 December 2022 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7607943
18 September 2022 PSC B · COC-CVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7557696
22 January 2020 PSC A · COC-CVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6893740
30 January 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6617779
10 September 2018 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6537213
1 February 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6348610
18 September 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6269847
14 September 2017 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6266731
20 September 2016 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6004890
19 September 2016 COC-CVE Quarterly
Type not classified · Sector New York · USCG Northeast District (CGD-NE) · Activity 6003955
15 April 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5854603
5 April 2016 Ballast Water Examination · COC-CVE Annual · ISPS II Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5847195

Deficiency record · 17

04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 20 March 2026 Resolved
THE MUSTER LIST SHALL SHOW THE DUTIES ASSIGNED TO THE DIFFERENT MEMBERS OF THE CREW INCLUDING: CLOSING OF THE WATERTIGHT DOORS, FIRE DOORS, VALVES, SCUPPERS, SIDE SCUTTLES, SKYLIGHTS,PORTHOLES AND OTHER SIMILAR OPENINGS IN THE SHIP. PSCO OBSERVED NO MIDSHIP STAIRWELL GUIDES ON DECK 11. 74SOLAS20 III/37.3.1 17C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2026
Resolved 21 March 2026
Resolution: Recieved amended mustser list assigning 02 crew members to the deck 11 stairwell. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 March 2026 Resolved
Stairway enclosures shall have direct access to the corridors and be of a sufficient area to prevent congestion, having in view the number of persons likely to use them in an emergency. Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustible material providing storage for safety equipment and open information counters are permitted. PSCO observed numerous carts, pallets and other storage items in a category 2 space on the bulkhead deck just forward of the pod rooms. 74 SOLAS (01) II-2/29.2 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 March 2026
Resolved 21 March 2026
Resolution: Recieved pictures of the space forward of the POD room. The space is now free of obstructions. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 20 March 2026 Resolved
EXHAUST DUCTS FROM GALLEY RANGES IN WHICH GREASE OR FAT IS LIKELY TO ACCUMULATE SHALL BE FITTED WITH A FIRE DAMPER LOCATED IN THE LOWER END OF THE DUCT WHICH IS AUTOMATICALLY AND REMOTELY OPERATED, AND IN ADDITION A REMOTELY OPERATED FIRE DAMPER LOCATED IN THE UPPER END OF THE DUCT. PSCO OBSERVED FIRE DAMPER INDICATOR IN ACS 10.2 UNABLE TO INDICATE OPEN OR CLOSED. 74 SOLAS 01 II-2/32.1.9.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 26 March 2026
Resolution: Recieved satisfactory pictures of indicator replacement and record from planned maintenance system.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 March 2026 Resolved
THE CONSTUCTION OF ALL DOORS AND DOOR FRAMES IN "A" CLASS DIVISIONS, WITH THE MEANS OF SECURING THEM WHEN CLOSED, SHALL PROVIDE RESISTANCE TO FIRE AS WELL AS TO THE PASSAGE OF SMOKE AND FLAME, AS FAR AS PRACTICABLE, EQUIVALENT TO THAT OF THE BULKHEADS IN WHICH THE DOORS ARE SITUATED. SUCH DOORS AND DOOR FRAMES SHALL BE CONSTRUCTED OF STEEL OR OTHER EQUIVALENT MATERIAL. PSCO OBSERVED FIRE DOOR 2.1.06 UNABLE TO SLIDE SHUT DUE TO CLOSING MECHANISM NOT ACTUATING WHEN ACTIVATED. 74 SOLAS 01 II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 30 March 2026
Resolution: Recieved satisfactory pictures of repair and record from planned maintenance system
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 March 2026 Resolved
EVERY CREW MEMEBER WITH ASSIGNED EMERGENCY DUTIES SHALL BE FAMILIAR WITH THESE DUTIES BEFORE THE VOYAGE BEGINS. PSCO OBSERVED LIFEBOAT COMMANDER ON LIFEBOAT 15 UNABLE TO FIND THE FUEL SHUTOFF VALVE AND WAS UNFAMILIAR WITH ON LOAD RELEASE. ADDITIONALLY, LIFEBOAT COMMANDER AND 2ND OFFICER OF LIFEBOAT 17 DID NOT KNOW WHERE THE FUEL SHUTOFF VALVE WAS. 74 SOLAS 20 III/19.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 30 March 2026
Resolution: Provided satisfactory documentation of lifeboat familiarzation training.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 September 2024 Resolved
Each section of sprinklers shall include means for giving a visual and audible alarm signal automatically at one or more indicating units whenever any sprinkler comes into operation. Such alarm systems shall be such as to indicate if any fault occurs in the system. During the testing of section valves 18 and 29, indication on bridge for the intrusion alarm and flow meter displayed a different main vertical zone (MVZ) than what is marked at each section valve locally, both section valves are marked to supply MVZ 07. Section valve 29 intrusion alarm indicates MVZ 06 and the flow alarm indicates MVZ 01. Section valve 18 intrusion alarm indicates MVZ 05. 74 SOLAS (01) II-2/12.1.2. - Code 07109 - Action 40ac.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 September 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. During testing, hinged fire door, 0A.4.36, in crew galley did not latch. 74 SOLAS (01) II-2/30.4.2. – Code 07105 – Action 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 September 2024
Resolution: Ship's personnel adjusted closing device on fire door. PSCO witnessed satisfactory operation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 September 2024 Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention in 2 min an audible alarm shall be automatically sounded throughout the crew accommodation and service spaces, control stations, and machinery spaces of category A. Manual call point in the forward vacuum collection space was found not operational when tested. 74 SOLAS (01) II-2/13.1.4. – Code 07106 – Action 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 September 2024
Resolution: Ship's personnel performed maintenance on affected manual call point. PSCO witnessed satisfactory operational test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 December 2022
Resolved 8 December 2022
Resolution: Vessel agent payed the pentalty amount prior to vessel's departure.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 September 2022 Resolved
Means of escape shall be marked by lighting or photoluminescent strip indicators placed not more than 0.3 meters above deck to enable passengers to identify all routes of escape and identify the escape exits. The low location lighting strip indicating exit in front of cabin G 105 was not illuminated. 74 SOLAS 01 II-2/28.1.10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 September 2022
Resolution: Low Location Lighting was repaired.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 September 2022 Resolved
The minimum for integrity of all bulkheads and decks shall be as prescribed in tables 26.1 and 26.2. Storage of combustable materials in the form of boxes found throughout AC spaces (category 10 spaces) namely AC space in the way of FSD 01.2.61. 74 SOLAS 01 II-2/26.2.2 (10).
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 18 September 2022
Resolution: Space was cleared of combustable boxes.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 14 September 2017 Resolved
THE MINIMUM FIRE INTEGRITY OF ALL BULKHEADS AND DECKS SHALL BE AS PERSCRIBED IN TABLE 26.1. VESSEL HAS REMOVED INSULATION FROM INCINERATOR ROOM BULKHEAD. BULKHEAD BOUNDS ECAVUCATION STATION, VIOLATIING REQUIRED A-60 BOUNDARY ON STBD DK D, FZ 2. 74 SOLAS (01 CONS) II-2/26 17A
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2017
Resolved 18 September 2017
Resolution: Class Report provided.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 September 2017 Resolved
THE MEANS OF ESCAPE, INSLCUDING EXITS, SHALL BE MARKED BY LIGHTING OR PHOTOLUMINSECENT STRIP INDICATORS. EXITS FROM THE STAGE OF THE THEATER, DRESSING ROOM, AND COSTUME STORAGE ARE NOT MARKED. 74 SOLAS (01 CONS) II-2/28.1.10 10C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2017
Resolved 18 September 2017
Resolution: Corrected on the spot.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 20 September 2016 Resolved
Failed to meet the 24hr requirement.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 20 September 2016
Resolution: Provided vessel with guidence on ANOA policy
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 April 2016 Resolved
1730 - Oily-water separating equipment - After any survey of the ship has been completed, no change shall be made in the equipment, systems, fitting, and arrangements covered by the survey. 2 of the ship's 3 oily water separators - Facet and Westfalia - were found inoperable. 73 MARPOL (2011 Cons.) I/6.4.2
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 14 April 2016
Resolution: Class report from Lloyd's accepted as evidence that this deficiency has been corrected.
Lifesaving › Launching Appliances › Davit
Issued 5 April 2016 Resolved
0630 - Launch arrangt. for survival craft - Before the ship leaves port and at all times during the voyage, all life-saving appliance shall be in working order and ready for immediate use. Lifeboat 9 davit is fractured in one location, making it unsafe for use. 74 SOLAS (2014 Cons.) III/20.2
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 14 April 2016
Resolution: Tech report from International Inspection accepted as evidence that this deficiency has been corrected.
Documentation › Logs/Records › Oil Record Book
Issued 5 April 2016 Resolved
1710 - Oil record book - Each completed page of the Oil Record Book Part I shall be signed by the master of the ship. 19 completed pages in the Oil Record Book were completed but not signed by the master. 73 MARPOL (2011 Cons.) I/17.4
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 5 April 2016
Resolution: Master reviewed the Oil Record Book and signed all completed pages.