BONANZA

BONANZA is a 2003 freight ship. The Coast Guard has recorded 17 inspections since 2005, most recently in November 2021, along with 6 deficiencies and 3 operational controls.

Records from 2005 to 2021. Most recent: inspection, 20 November 2021.

Built
2003
Last inspected
20 November 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9273210 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
740167
Flag
LIBERIA
—
Maury page id
psix-740167

Inspections, by type

…with no type recorded5
Years with a record 11 calendar years (2005–2021)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it73613 - Dead Weight, Metric Ton
85702 - Displacement, Metric Ton
40160 - Convention (Subpart B), Gross Ton
25869 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

20 November 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7345980
29 December 2019 ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6876953
17 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6875685
29 May 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6689753
15 July 2017 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6212115
14 July 2017 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6209424
6 January 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6067149
5 January 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6066671
29 November 2016 ISPS II Exam · Ballast Water Examination · Administrative Inspection · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6049588
20 June 2014 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4893262
26 September 2011 ISPS II Exam · PII Safety Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4148794
8 January 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3655425
30 December 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3655444
22 November 2008 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3357692
21 February 2006 MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2588826
23 March 2005 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2317456
22 March 2005 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2317181

Deficiency record · 6

Engineering › Fuel Oil Service System › Piping
Issued 29 November 2016 Resolved
The lagging on the fuel return lines on the main propulsion engine were soaked with oil and not adequate for the service for which they were intended.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2016
Resolution: New engine room legging fabricated and installed by ITS Maritime Services for all deficient sections.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 8 January 2010 Resolved
0735 - Personal equipment - fire fighting - Firemen’s outfits should protect the wearer from burns and scalding steam; outer layer shall be water resistant. During fire drill, PSCO conducted examination of firemen's outfits and found one suit with a hole and water resistant material on all suits severely deteriorated.- SOLAS 2001 II-2/17
Action required: 705 - Other - as specified
Due 15 January 2010
Resolved 15 January 2010
Resolution: Received, reviewed and accepted proper documentation from master stating the deficiency was rectified. Vessel''''s master provided receipt for the purchase of two new fire suits.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 8 January 2010 Resolved
1030 - Steering Gear Alarm - An audible and visual alarm shall be given on the navigational bridge in the event of power failure to any one of the steering gear power units. Audible alarm was inoperable on the bridge.
Action required: 705 - Other - as specified
Due 8 January 2010
Resolved 8 January 2010
Resolution: Ships Electrician found wire disconnected and repaired. Conducted alarm test, audible and visual operable.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 23 March 2005 Resolved
Vessel is using storage container on weather deck "B" as paint locker with no fixed fire suppression sys. Vessel must provide fire suppression sys in accordance with SOLAS 2004 consolidated ch. II-2,reg.6.3.1
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2005
Resolution: Vessel plumbed in sea water sprinkler system in to (container) paint locker. Vessels fire main supplys system.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 March 2005 Resolved
Vessel ENG room work space was not in compliance with ships fire control plan.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 March 2005
Resolved 23 March 2005
Resolution: Modified bulkhead to create partial boundary IAW fire control plan.
Lifesaving › Launching Appliances › Davit
Issued 23 March 2005 Resolved
3 Cracks found at base of PORT side life boat gantry support beam. 1 crack found on STBD in same location. Although already called out in Class Survey report, the cracks appeared to be getting worse (instead of two cracks there are now four).
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2005
Resolution: All supports with cracks have been replaced and re-welded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.