MAURY USCG vessel records Sign in
← All vessels

MISS RAI

MISS RAI is a 2000 commercial fishing vessel. The Coast Guard has recorded 11 inspections since 1999, most recently in July 2007, along with 13 deficiencies.

Records from 1999 to 2007. Most recent: inspection, 6 July 2007.

Built
2000
Last inspected
6 July 2007
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2656
Flag
UNITED STATES
367118130 (licence lapsed)
Maury page id
psix-7403

Inspections, by type

Years with a record 7 calendar years (1999–2007)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)55.0 ft × 13.0 ft × 3.3 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARMINE C COIRO · MARION, MD, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portSAXIS, VA
Trade endorsementsFishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD2656MMSI 367118130 · expired · compulsorily equipped · granted 31 May 2006, cancelled 6 August 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 11

6 July 2007 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2985943
13 July 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2439276
24 May 2005 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2415713
6 May 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2066647
6 May 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1824830
1 May 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1611324
23 May 2000 Hull Examination · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1373044
4 May 2000 Inclining Experiment
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1373033
9 February 2000 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1403050
1 March 1999 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1395117
19 February 1999 Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1421413

Deficiency record · 13

Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 13 July 2005 Resolved
Provide proof of enrollment for master and deck hand in a CG approved drug program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2005
Resolved 6 September 2005
Resolution: proof provided.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 July 2005 Resolved
Provide a certificate of inspection.
Due 13 July 2005
Resolved 6 September 2005
Resolution: provided copy.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 July 2005 Resolved
Show operation of high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2005
Resolved 6 September 2005
Resolution: operating properly7.
Engineering › Bilge Water Management System › Pump
Issued 13 July 2005 Resolved
Provide portable bilge pump.
Due 13 August 2005
Resolved 6 September 2005
Resolution: provided.
Documentation › Certificates/Documents › FCC SSL
Issued 13 July 2005 Resolved
Provide valid FCC station license, and safety certificate
Due 13 August 2005
Resolved 17 January 2006
Resolution: not required.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 13 July 2005 Resolved
Post oil pollution placard.
Due 13 August 2005
Resolved 6 September 2005
Resolution: posted.
Electrical › Electric Generation Source (service) › Conductor
Issued 24 May 2005 Resolved
Replace battery cable on stern where insulation has been chaffed off.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2005
Resolved 13 July 2005
Resolution: New cable installed.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 24 May 2005 Resolved
Replace deteriorated battery boxes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2005
Resolved 13 July 2005
Resolution: New boxes installed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 May 2004 Resolved
Provide proof of enrollment in drug testing program for all deckhands.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2004
Resolved 12 May 2004
Electrical
Issued 6 May 2004 Resolved
Provide cover for batteries.
Due 6 June 2004
Resolved 18 May 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 6 May 2004 Resolved
Show proof that B-I fire extinguisher has been serviced.
Due 6 May 2004
Resolved 12 May 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 May 2004 Resolved
Provide first aid kit.
Due 6 June 2004
Resolved 7 May 2004
Engineering
Issued 6 May 2004 Resolved
Provide portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2004
Resolved 7 May 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.