Records from 1995 to 2026. Most recent: inspection, 24 February 2026.
Inspection history · 40
24 February 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8316835
17 September 2025
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8236300
16 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8137768
6 May 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7916571
12 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7894049
25 September 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7798003
24 February 2023
Construction Oversight · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7647203
3 October 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7570636
11 July 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7504001
17 March 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7415533
7 March 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7407395
15 February 2022
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7348820
28 October 2020
DAPI Audit · Initial Certification · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7085725
20 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6485811
31 May 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6539796
22 March 2018
Plan Review (Other than "T") · Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6387950
24 August 2017
Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6251069
20 July 2017
DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6221125
2 July 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5175574
27 June 2013
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4634464
23 May 2013
Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4613075
13 February 2012
DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4243808
4 January 2012
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4218241
20 August 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3859714
6 May 2009
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3468999
22 April 2009
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3458750
20 November 2008
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3367039
21 June 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2969214
5 June 2007
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2952525
12 August 2005
Uninspected Other
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2550535
13 January 2005
MTSA Verification · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2268810
17 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968853
14 March 2002
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1494718
6 February 2001
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1058454
23 February 2000
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1046629
7 October 1999
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 786898
23 February 1999
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 795661
5 February 1998
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1112420
30 April 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 89208
24 August 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 382206
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2025
Resolved
Verification of design standards must be conducted on a vessel on which a new installation that is not a replacement in kind before the installation is performed. The auxiliary heating boiler in the engie compartment is a nw installation. No design verification has been performed. Complete design verification of aux boiler in engie compartment following the procedures in 46 CFR 144.145.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 17 September 2025
Resolution: The heating boiler was removed from the engine compartment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2025
Resolved
Electrical systems and equipment must function properly, minimize failures, fire and shock hazards. Two junction boxes in the engine compartment have wires hanging out. Repair the same.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 September 2025
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 16 May 2025
Resolved
The master must ensure all watertight doors function properly. The two forward watertight doos gaskets are compressed and not watertight. Replace the gaskets with proper material.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2025
Resolved
Decks and bulkheads designed to be watertight must be maintained in that condition. The watertight bulkheads in the forward part of the engine compartment have penetrations that are not watertight. Make penetrations watertight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2025
Resolution: Witnessed repairs to watertight penetrations in engine room bulkheads.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 May 2025
Resolved
VESSEL O/O HAS NO CURRENT CREW/EMPLOYEES AND IS IN AN IN-ACTIVE STATUS. VESSEL MUST COMPLY WITH ALL SECURITY REQUIREMENTS PRIOR TO OPERATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2026
Resolution: Vessel has been inactive since 2024 and does not intend to push red flag barges, so no security plan is required.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 May 2025
Resolved
VESSEL O/O HAS NO CURRENT CREW/EMPLOYEES AND IS IN AN IN-ACTIVE STATUS. VESSEL MUST COMPLY WITH ALL HEALTH AND SAFETY PLAN TRAINING PRIOR TO OPERATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2026
Resolution: Contracted crew has completed all health and safety training with under the TSMS of Middle river Marine and a vessel safety orientation.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 16 May 2025
Resolved
VESSEL O/O HAS NO CURRENT CREW/EMPLOYEES AND IS IN AN IN-ACTIVE STATUS. VESSEL MUST CONDUCT DRILLS AND RUN MACHINERY WITH LOCAL [name withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2026
Resolution: Got underway and conducted man overboard a fire drill. Drills SAT.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 May 2025
Resolved
WHEN VESSEL IS READY TO BE CREWED, THEY MUST BE DRUG TESTED AND ENROLLED IN EMPLOYEE PROGRAM MEETING ALL REQUIREMENTS FOR DAPI PRIOR TO OPERATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2026
Resolution: Verified crew onboard is enrolled in a DAPI program.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 April 2024
Resolved
LABEL BRIDGE ELECTICAL POWER PANEL.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 April 2024
Resolution: POWER PANEL HAS BEEN LABELED.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 April 2024
Resolved
MOUNT IBA FOR AUTOMATIC RELEASE OPERATION PRIOR TO OPERATING.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 May 2025
Resolution: IBA has been setup for automatic release operation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 April 2024
Resolved
REPLACE GFCI RECEPTACLES FOR GALLEY MICROWAVE AND STBD HEAD. REMOVE DEADENDED CABLES IN ENGINE ROOM.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2024
Resolved 6 May 2024
Resolution: GFCIs have been replaced and deadended cables removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2024
Resolved
VESSEL O/O HAS NO CURRENT CREW/EMPLOYEES AND IS IN AN IN-ACTIVE STATUS. VESSEL MUST COMPLY WITH ALL SECURITY REQUIREMENTS PRIOR TO OPERATION.
Action required: 705 - Other - as specified
Resolved 16 May 2025
Resolution: Deficiency was re-issued during 2025 Annual.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 April 2024
Resolved
VESSEL O/O HAS NO CURRENT CREW/EMPLOYEES AND IS IN AN IN-ACTIVE STATUS. VESSEL MUST COMPLY WITH ALL HEALTH AND SAFETY PLAN TRAINING PRIOR TO OPERATION.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 May 2025
Resolution: Deficiency was re-issued during 2025 Annual.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 April 2024
Resolved
VESSEL O/O HAS NO CURRENT CREW/EMPLOYEES AND IS IN AN IN-ACTIVE STATUS. VESSEL MUST CONDUCT DRILLS WITH LOCAL OCMI AND PROVIDE PROOF OF DAPI DOCUMENTATION PRIOR TO OPERATION.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 May 2025
Resolution: Deficiency was re-issued during 2025 Annual.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 April 2023
Resolved
AFT WTD IN GALLEY NEEDS ADJUSTING TO BE WATERTIGHT.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 5 May 2023
Resolution: Gasket material was replaced, WTD is adjusted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 April 2023
Resolved
ALL WTD ON VESSEL NEED TO BE LABELED IN LEGIBLE LETTERS AT LEAST 1" HIGH ON BOTH DOOR SIDES: "WATERTIGHT DOOR - KEEP CLOSED".
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 5 May 2023
Resolution: All WTDs have been properly marked "WATERTIGHT DOOR - KEEP CLOSED".
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 April 2023
Resolved
VESSEL COI REQUIRES 8 IMMERSION SUITES ON BOARD. VESSEL HAS 4. VESSEL TOTAL PERSONS ON BOARD IS REDUCED TO 4 UNTIL 8 SUITES ARE PROVIDED.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 25 September 2023
Resolution: Vessel has provided 08 immersion suites.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 April 2023
Resolved
ALL RENEWED ELECTRICAL CABLE/CONDUCTORS INSTALLED NEED TO BE MOUNTED/SUPPORTED BY METAL AT LEAST EVERY 48".
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 5 May 2023
Resolution: Electrical cables/conductors are supported by metal at least every 48".
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2023
Resolved
INSTALL INSULATION ON BOTH PROPULSION ENGINE EXHAUST DUCTS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 5 May 2023
Resolution: Both propulsion engine exhaust ducts have been insulated.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 March 2022
Resolved
A 1 foot fracture wwas found port side hull plate under the rub rail in the forepeak. Reweld and prove watertight.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2022
Resolved 7 March 2022
Resolution: Fracture was gouged,welded inside and out.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 March 2022
Resolved
Aft engineroom vents on stacks are missing vent closures. Provide proper closure devices.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2022
Resolved 7 March 2022
Resolution: New dampers are installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 March 2022
Resolved
Vessel Fire Detection panel hass fault code in the crew space zone. Prove proper operation of the Fire Detection panel prior to returning vessel to service.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2022
Resolved 11 March 2022
Resolution: Panel was renewed with Model meeting UL national lab standard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2022
Resolved
The portside air receiver relief valve is undersized for capacity of compressor. Install relief valve of adequate size to properly vent volume of compressor in the event of overpressurizing system.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2022
Resolved 17 March 2022
Resolution: Larger relief valve was installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 16 December 2020
Resolved
Captain at the time of inspections First Aid Training was expired in March 2020. Captain needs to complete training prior to operating as Captain. 46 CFR 140.210
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2021
Resolution: Rvcd proof of training from vessel rep.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2020
Resolved
PORT water tight door in galley gasket needs to be replaced.
46 CFR 144.320
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2021
Resolution: Gasket was replaced.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 December 2020
Resolved
Slack was identified in the STBD side emergency fuel shutoff valve cabling. The shutoff was operational, the amount of slack creates a possible snag hazard that could affect operation during emergency. 46 CFR 143.260
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2021
Resolution: Slack was removed from cabling
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2020
Resolved
110/220 electrical panel STBD side engine room missing breaker door latch. 46 CFR 143.560
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2021
Resolution: Latch was installed on panel cover.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 December 2020
Resolved
FWD main deck PORT side water tight door needs gasket replacement. 46 CFR 144.320
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 January 2021
Resolution: Gasket was replaced.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 31 May 2018
Resolved
The vessel is currently broadcasting (1) Name: must drop the M/V to match the registered name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 6 July 2018
Resolution: Made corrections to AIS
Communications › Visual Communication › Red Warning Signal
Issued 5 June 2007
Resolved
General alarm flashing red light in engine room not working as required under 46 CFR 27.201(a)(3)
Condition: Improper/Lack of Maintenance
Due 5 July 2007
Resolved 21 June 2007
Resolution: General alarm flashing red light in engine room now working
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 June 2007
Resolved
Remote fuel oil shutoff valve port side not at tank as required under 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Due 5 July 2007
Resolved 21 June 2007
Resolution: Remote fuel oil shutoff valve port side now in correct position
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 June 2007
Resolved
Remote fuel oil shutoff operating procedures / markings starboard side not displayed as required under 46 CFR 27.207
Condition: Improper/Lack of Maintenance
Due 5 July 2007
Resolved 21 June 2007
Resolution: Operating procedures / markings starboard side for remote fuel oil shutoff now properly displayed
Unknown
Issued 24 August 1995
Resolved
Vessel not in compliance with applicable PPR's
Condition: Unknown
Due 9 September 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past