Records from 2005 to 2026. Most recent: inspection, 19 August 2026.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CLERMONT, NJ, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
19 August 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8468916
27 May 2025
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8135867
10 March 2025
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8091397
21 January 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8083797
18 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7937863
1 May 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7678903
23 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7631300
23 September 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7565009
9 August 2021
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7281384
20 January 2021
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7127506
27 July 2020
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7017782
24 July 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7015384
18 June 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6717719
15 February 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6626500
19 June 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6449778
12 June 2017
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6174068
13 January 2017
In-Service Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6070649
6 June 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5898909
20 July 2012
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4385142
15 June 2012
Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4345242
27 January 2012
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4233314
16 February 2011
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3946750
17 July 2009
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3537265
16 March 2009
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3420299
14 May 2008
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3190596
18 May 2007
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2926090
15 March 2007
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2903265
23 May 2006
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2656742
21 April 2006
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2624703
6 May 2005
Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2353026
19 January 2005
Simplified Stability Test · Construction Oversight · Plan Review "T" Boat
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2319751
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 May 2025
Resolved
Forward bulkhead in engine room was not adequately sealed for the fixed Fireboy system. Adequately seal the forward bulkhead to the satisfaction of the attending USCG marine inspector.
Cite: 46 CFR 181.420.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 May 2025
Resolution: Bulkhead sealed appropriately.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 June 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 10 July 2024
Resolution: Received photo of DAPI enrollment.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 June 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel safety radiotelephony certificate was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 10 July 2024
Resolution: Received photo of vaild radiotelephony certificate.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 June 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Forward bilge audible alarm was very quite. Fix alarm and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 10 July 2024
Resolution: Received video of bilge alarm working properly.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 1 May 2023
Resolved
Vessel engine found to have unprotected moving parts. Install fwd serpentine belt cover.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 31 May 2023
Resolution: Installed manufacturer's protective cover.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 May 2023
Resolved
Ring buoy found to be installed without using retroreflective tape. Install tape to ring buoy.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2023
Resolved 31 May 2023
Resolution: Installed reflective tape
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2021
Resolved
Propulsion auxiliary cooling strainer showed surface cracks on acrylic cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2021
Resolved 9 September 2021
Resolution: Owner provided pictures of replaced cracked acrylic cover.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 July 2020
Resolved
A pre engineered fixed gas fire extinguishing system must automatically shut down all engines that draw intake air from within the protected space.
Installed Fireboy did not secure the main engine during testing.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2020
Resolution: Witnessed Satisfactory operational test of installed Fixed Fire fighting (Fire Boy) system.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 27 July 2020
Resolved
Vessel's Certificate of Documentation was found to be expired. Provide proof of the required documentation to the USCG.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2020
Resolution: Sent proof of COD
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2020
Resolved
A renewal inspection for certification must be completed by the expiration date of the Certificate of Inspection. A written application (CG-3752) for renewal inspection must be submitted to the cognizant [name withheld] completed page 1 of form CG-3752. Complete CG-3752 prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2020
Resolution: COI inspection completed.
Construction/Loadline › Hull › Hull Plating
Issued 13 January 2017
Resolved
Complete required hull and internal structural exam IAW 46 CFR 176.600(c)(1) (prior to carrying passengers for hire)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2017
Resolution: Completed hull and ISE exams.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 17 July 2009
Resolved
Provide DAPI documentation to Marine Inspector.
Action required: 705 - Other - as specified
Resolved 22 July 2009
Resolution: Owner provided DAPI documentation to satisfaction Marine Inspector.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 July 2009
Resolved
Charts 2 years old. Provide updated charts to marine inspector.
Action required: 705 - Other - as specified
Resolved 22 July 2009
Resolution: Owner provided updated charts.
Lifesaving › Lifebuoys › Serviceable
Issued 17 July 2009
Resolved
Retro tape on ring buoy covered by vsl name. Stall 4 even spaced out retro tape on both sides ring buoy.
Action required: 705 - Other - as specified
Resolved 22 July 2009
Resolution: O/O re-installed retro tape on ring buoy to satisfaction of Marine Inspector.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 July 2009
Resolved
re-lable life jacket stowage label.
Action required: 705 - Other - as specified
Resolved 22 July 2009
Resolution: O/O re-labled life jacket stowage.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 17 July 2009
Resolved
Replace flare container with water tight approved container.
Action required: 705 - Other - as specified
Resolved 22 July 2009
Resolution: Owner replaced flare container with approved container.
Lifesaving › Hand Flares › Not on Board
Issued 23 April 2008
Resolved
Provide 3 red and 6 orange flares.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2008
Documentation › Certificates/Documents › FCC SSL
Issued 23 April 2008
Resolved
Provide update operator FCC license.
Condition: Placed in Improper Service
Due 15 May 2008
Resolved 15 May 2008
Communications › Radio Communications › EPIRB
Issued 18 May 2007
Resolved
Update EPIRB registration.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 18 May 2007
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 May 2007
Resolved
Relocate and update number for children Lifejackets.
Condition: Improper Installation
Due 25 May 2007
Resolved 18 May 2007
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 18 May 2007
Resolved
Provide annual drug program report.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 18 May 2007