HOEGH SEOUL is a 2004 freight ship. The Coast Guard has recorded 11 inspections since 2016, most recently in July 2026, along with 5 deficiencies and 1 operational control, 1 with no removal date recorded.
Records from 2016 to 2026. Most recent: inspection, 17 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it68871 - Regulatory (Subpart C or D), Gross Ton 68871 - Convention (Subpart B), Gross Ton 25912 - Regulatory (Subpart C or D), Net Ton 25912 - Convention (Subpart B), Net Ton 46830 - Displacement, Ton 27227 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
17 July 2026PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8440442
14 April 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8111264
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 15 April 2016Resolved
(1410) The Coolant Line for the central cooling system on the main engine and auxiliary generators has an uncontrolled leak on a flange allowing a free flow of water into the engine room. 74 SOLAS (04 cons.) I Reg 11a (16ac)
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 20 April 2016
Resolution: Condition of class imposed in order for owner to supply spare parts as required. In the meantime the leak is to be kept under close oberservation.
Engineering › Lubricating Oil Service System › Piping
Issued 15 April 2016Resolved
(0910) The high pressure delivery lines to the ships pumps in line to the cargo ramps are leaking at all connection points. 74 SOLAS (04 cons.) II-2 Reg 4.2.2.4 (15ac)
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2016
Resolution: Received class report stating all flanges were re-tightened and leaks rectified.
Engineering › Fuel Oil Service System › Valve
Issued 15 April 2016Resolved
(1499) The inboard piping for the heavy fuel oil pump is leaking from the stem valve due to a loose packing gland. 74 SOLAS (04 cons.) II-2 Reg. 4.1.1 (15ac)
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2016
Resolution: Received class report stating packing gland was renewed to rectify deficiency.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 15 April 2016Resolved
(1420) Numerous buckets of oil were found overfilled and stored improperly within the steering gear room and the engine room causing fire and safety hazards to the crew. 74 SOLAS (04 cons.) II-2 Reg. 4.1.1 (15ac)
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2016
Resolution: Received class report stating all buckets of oil were removed and space cleaned.
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 15 April 2016Resolved
(0950) The main bus tie on the switchboard in the emergency generator space has been repaired and now has open spaces allowing access into the switchboard. 74 SOLAS (04 cons.) II-1 Reg. 40.1.3 (15ac)
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2016
Resolution: Received class report stating cover plate was fabricated and fitted.