MAURY USCG vessel records
← All vessels

PURSUIT

PURSUIT is a 2005 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in May 2026, along with 10 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 27 May 2026.

Built
2005
Last inspected
27 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 May 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH9866
740831
Flag
UNITED STATES
Maury page id
psix-740831

Documentation record

Registered dimensions (L × B × D)35.0 ft × 11.0 ft × 5.5 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFIBERCRAFT INC · BLAINE, WA, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 1 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

27 May 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8420854
28 April 2026 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8357785
9 April 2025 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8109140
2 May 2024 Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7905581
20 June 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7718966
4 June 2022 Type not recorded
No type recorded · USCGC MUSTANG (WPB 1310) · USCG Arctic District (CGD-A) · Activity 7480959
17 May 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7453896
12 June 2021 Type not recorded
No type recorded · USCGC BAILEY T. BARCO (WPC 1122) · USCG Arctic District (CGD-A) · Activity 7243692
25 May 2021 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7207001
5 May 2020 Internal Structural Exam · Drydock Exam · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6953425
5 June 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6705143
31 May 2018 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6417266
20 April 2018 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6396002
26 June 2017 Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 6189132
18 May 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6233240
17 May 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5923628
27 April 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5860539

Deficiency record · 10

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 June 2023 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel Communications Act Safety Radiotelephony certificate expired 31 May 2023. 46CFR184.502, 47CFR80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 17 July 2023
Resolution: Received scanned copy of renewed FCC Safety Radiotelephony Certificate from operator.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 May 2022 Resolved
Each vessel that opeartes on the high seas must have onboard a FCC Type Category 1 406 mHZ EPIRB. The vessel's EPIRB battery is expired. Replace the EPIRB battery. Vessel is restricted to operations no more than 3 nautical miles from shore. 46CFR180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 May 2022
Resolution: Received satisfactory photographic proof of resolution. Def cleared.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 May 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect against fire, caused by or originating from electrical equipment. The anchor winch 12V relay is showing signs of failure. Replace electrical relay in-kind. 46CFR183.200(b)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2022
Resolved 17 May 2022
Resolution: Operator provided photograph of relay replaced in-kind.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 May 2021 Resolved
Fixed fire extinguishing system fails to automatically shut down engines in the protected space Ensure system operates correctly prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2021
Resolution: Local technician rewired the unit. Shutdowns occured as normal. All Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 May 2021 Resolved
Update first aid kit. Medicine expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 May 2021 Resolved
Provide means for alcohol testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 May 2021 Resolved
Ensure vessel has adequate number of distress signals (6&6). Missing 01.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 May 2021
Resolution: Purchased 01 flares. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 19 May 2020 Resolved
Lift raft was being serviced and not on vessel. Ensure life raft is properly installed prior to carrying pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2020
Resolution: life raft was properly installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2020 Resolved
Ensure vessel is equiped with 03 approved fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2020
Resolved 21 May 2020
Resolution: fire buckets on board
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 May 2020 Resolved
Vessel is on oceans route and did not have capability to conduct alcohol test within two hours of marine casualty.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2020
Resolved 21 May 2020
Resolution: Test strips on board

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.