MAURY USCG vessel records
← All vessels

SAGITTARIUS LEADER

SAGITTARIUS LEADER is a 2005 freight ship. The Coast Guard has recorded 15 inspections since 2016, most recently in May 2026, along with 7 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 27 May 2026.

Built
2005
Last inspected
27 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 May 2026
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9283887
740842
Flag
JAPAN
Maury page id
psix-740842

Documentation record

Tonnage as PSIX records it62397 - Convention (Subpart B), Gross Ton
18719 - Convention (Subpart B), Net Ton
38562 - Displacement, Metric Ton
20098 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

27 May 2026 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8377556
7 August 2025 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8204538
29 November 2023 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7828173
4 May 2023 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681039
1 July 2022 PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7490703
2 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7404622
26 October 2021 PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7338677
2 December 2020 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7105166
25 November 2020 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7098977
21 July 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7012701
24 April 2019 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6669339
11 January 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6607065
16 April 2018 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392488
9 January 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6331999
26 September 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6007181

Deficiency record · 7

14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 1 July 2022 Resolved
Each Ballast Water System manufactured under Coast Guard approval must have a name plate securely fastened to the BWMS. PSCO observed no name plate on BWMS. - 46 CFR 162.060-22 - 40C
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 May 2023
Resolution: Vessel does not have a US Coast Guard approved system on board so the deficiency was added in error. Vessel also confirms that they do not discharge ballast in U.S. Waters.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 25 November 2020 Resolved
A food ration must be available for each person the lifeboat is permitted to accommodate. Lifeboat 1 had one bad food ration.74 SOLAS 14 III/34
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 December 2020
Resolved 2 December 2020
Resolution: Received photographic evidence that the vessel procured 01 food ration.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 January 2019 Resolved
Port service generator flame detector covered with a dust mask by crew.
Action required: 10 - Deficiency Rectified
Due 11 January 2019
Resolved 11 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 11 January 2019 Resolved
EPIRB hydrostatic release was expired.
Action required: 10 - Deficiency Rectified
Due 11 January 2019
Resolved 11 January 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 January 2019 Resolved
An electrical step down device was installed by the crew in the officers laundry room.
Action required: 10 - Deficiency Rectified
Due 11 January 2019
Resolved 11 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 January 2019 Resolved
The aft stairway accomodation door A-60 boundry does not self-close
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 24 April 2019
Resolution: Recieved Class report attesting to repairs.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 9 January 2018 Resolved
The fixed fire detection system shall be capable of rapidly detecting the onset of fire. Smoke detection 0142, 1432 & 0466 on deck 10 are inoperable. Conduct hourly fire inspection including area of each inopperable detector.
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 16 April 2018
Resolution: RECEIVED CLASS REPORT ATTESTING TO PROPER REAPIRS, CLASS REPORT ATTACHED.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.