MAURY USCG vessel records
← All vessels

SC5747BP

SC5747BP is a 2003 passenger vessel (inspected). The Coast Guard has recorded 7 inspections since 2016, most recently in February 2025, along with 24 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 13 February 2025.

Built
2003
Last inspected
13 February 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 February 2025
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

740863
Flag
UNITED STATES
Maury page id
psix-740863

Documentation record

Tonnage as PSIX records it1 - Simplified, Gross Ton
1 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

13 February 2025 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8079103
28 January 2021 Examination of Repairs · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7132470
24 January 2020 Deficiency Check · COI Inspection · DAPI Audit · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6895668
23 January 2019 Examination of Repairs · Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6614115
17 January 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6338994
11 January 2017 Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6070497
30 March 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5850089

Deficiency record · 24

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 February 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is missing 06 adult lifejackets. 46 CFR §180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2025
Resolution: Vessels placed on inactive status and COI was deactivated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2021 Resolved
Life ring be approved in accordance with §160.050 in subchapter Q of this chapter, or other standard specified by the Commandant. Grab line on life ring is deteriorated. 46 CFR §180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2025
Resolution: Vessels placed on inactive status and COI was deactivated.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 February 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. Contents of kit currently are expired or missing. 46 CFR §184.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2025
Resolution: Vessels placed on inactive status and COI was deactivated.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 February 2021 Resolved
A vessel not required to have a power driven fire pump by §181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Buckets are not marked “FIRE BUCKET”. 46 CFR §181.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2025
Resolution: Vessels placed on inactive status and COI was deactivated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 February 2021 Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25 (incorporated by reference; see 46 CFR 175.600). Fuel tanks must be secure from movement. 46 CFR §182.458
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2025
Resolution: Vessels placed on inactive status and COI was deactivated.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 1 February 2021 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. Aft port rail weld was cracked. 46 CFR §177.900
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 13 February 2025
Resolution: Vessels placed on inactive status and COI was deactivated.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 1 February 2021 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant [name withheld] is missing on board 46 CFR §184.300
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 13 February 2025
Resolution: Vessels placed on inactive status and COI was deactivated.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 February 2021 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies. Vessel has failed to conduct and log the required man overboard drills 46CFR 185.520
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2025
Resolution: Vessels placed on inactive status and COI was deactivated.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 February 2021 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel has failed to conduct and log the required Fire drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 13 February 2025
Resolution: Vessels placed on inactive status and COI was deactivated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 January 2020 Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25 or other standard specfied by the Commandant. 3/4 fuel tanks are West Marine, not ABYC H-25. Either show proof, or replace if not meeting requirement. One fuel tank is ABYC H-25, but is cracking. Replace that fuel tank regardless.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2020
Resolved 11 February 2020
Resolution: Fuel tank replaced with new West Marine ABYC H-25 portable fuel tank.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 January 2020 Resolved
A number of child size lifejackets equal to at least 10% of number of persons onboard must be provided. One child lifejacket in bad condition-remove from vessel and replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Destroyed in presence of MI during inspection. Still in compliance-required 2, still have 3 onboard. As of 11Feb2020, have a new child size lifejacket onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 January 2020 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Missing retroreflective tape on ring lifebuoy.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Retroreflective tape now on ring life buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 January 2020 Resolved
Remote fuel shutoff valves must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Missing labels for valve direction and name.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Fuel shut-off valve now labeled and shows direction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 January 2020 Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon buckets with an attached lanyard. The words "FIRE BUCKET" must be stenciled. Missing two buckets, label all three and attach lanyards.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Fire buckets now onboard with lanyard and labeling.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 January 2020 Resolved
A durable placard must be placed next to all radiotelephone installations with the emergency broadcast instructions and information specific to the individual vessel. Missing emergency broadcast placard from vessel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Broadcast placard mounted near operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 January 2020 Resolved
The number and identification of the items stowed inside, and their sizes must be marked in clearly legible letters and numbers on each container for lifejackets. Letters and numbers must be at least 2 inches high, Symbols must be at least 4 inches square. Lifejacket stowage says "11 adult lifejackets", needs to be changed to "12 adult lifejackets".
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 11 February 2020
Resolution: Updated lifejacket stowage markings
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 January 2020 Resolved
To maintain a valid Certificate of Inspection, you must complete an inspection for renewal of a COI prior to the expiration date on the COI. Vessel's COI expired on 02Jan2020.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2020
Resolved 29 January 2020
Resolution: COI inspection completed
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 January 2018 Resolved
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2018
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 17 January 2018 Resolved
Throttle Cables
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2018
Navigation › Piloting/Steering › Gyro Compass
Issued 17 January 2018 Resolved
Light extinguished
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2018
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 January 2017 Resolved
Renew vessel copy of nav rules.
Due 11 February 2017
Resolved 18 January 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 January 2017 Resolved
Renew light list
Due 11 February 2017
Resolved 18 January 2017
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 January 2017 Resolved
Provide proof of enrollment in drug consortium for crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2017
Personnel › Training › First Aid/CPR
Issued 11 January 2017 Resolved
Provide valid certification for first aid/CPR for vessel master (vessel not required to carry deckhand).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2017

Ownership record