Records from 2016 to 2026. Most recent: inspection, 3 February 2026.
Inspection history · 14
3 February 2026
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8303890
4 February 2025
Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8073976
24 January 2024
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7854194
7 February 2023
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7634625
22 February 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7400221
29 July 2021
Type not recorded
No type recorded · Station Tybee · USCG Southeast District (CGD-SE) · Activity 7286397
15 February 2021
Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7140901
14 January 2020
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6888940
11 February 2019
DAPI Audit · Internal Structural Exam · Drydock Exam · Hull Examination · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6615877
11 December 2018
Simplified Stability Test
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6598733
2 February 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6354909
1 January 2018
Special
Type not classified · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6346739
2 February 2017
Annual Inspection · DAPI Audit · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6079680
2 February 2016
Administrative Inspection · Hull Examination · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5808933
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 February 2025
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in 46 CFR subchapter Q, or other standard specified by the Commandant.
Ring life buoy retroreflective tape is worn and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2025
Resolved 14 February 2025
Resolution: Received photographic evidence retro was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 February 2021
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
stern light was extinguished.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 February 2021
Resolution: O/O replaced the stern light
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 February 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
(1) Charts of large enough scale to make safe navigation possible
Chart was not updated since 2010 for the area operating.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2021
Resolved 12 March 2021
Resolution: Vessel recieved new charts
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 February 2021
Resolved
Each lifeline on a ring life buoy must:
(1) Be buoyant;
(2) Be of at least 18.3 meters (60 feet) in length;
(3) Be non-kinking;
(4) Have a diameter of at least 7.9 millimeters ( 5/16 inch);
(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.
Life line was not of proper material
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2021
Resolved 12 March 2021
Resolution: New Line bag with appropriate line installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 February 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
Contents listed under 46CFR160.041 missing
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 February 2021
Resolution: O/O had a replacement first aid kit and placed it in service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 February 2021
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails.
FWD port and stbd accesses missing required number of courses
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2021
Resolved 25 February 2021
Resolution: O/O replaced the required fwd courses
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 February 2021
Resolved
Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.
Battery was expired and replace on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 February 2021
Resolution: O/O replaced the battery with new one
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 February 2020
Resolved
Except as otherwise provided, every vessel must be fitted with a suitable magnetic compass, mounted at the primary operating station, the compass must be illuminated. Vessel is restricted to good visibility and day time operations only.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2020
Resolved 12 February 2020
Resolution: Compass installed.