MAURY USCG vessel records Sign in
← All vessels

CRACKERJACK VOYAGER

CRACKERJACK VOYAGER is a 2005 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2005, most recently in June 2026, along with 41 deficiencies and 1 casualty investigation in 2012.

Records from 2005 to 2026. Most recent: inspection, 9 June 2026.

Built
2005
Last inspected
9 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI7934
741356
Flag
UNITED STATES
367733670
Maury page id
psix-741356

Inspections, by type

…with no type recorded3
Years with a record 18 calendar years (2005–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.0 ft × 14.5 ft × 8.0 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMODUTECH MARINE, INC · TACOMA, WA, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton
27 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI7934MMSI 367733670 · active · compulsorily equipped · granted 22 April 2026, expires 11 May 2036
WDC4830MMSI 338431000 · expired · compulsorily equipped · granted 7 April 2005, cancelled 13 June 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 29

9 June 2026 Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8397666
25 September 2025 Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8242033
23 April 2025 COI Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8118207
19 April 2024 Drydock Exam · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7898396
28 July 2023 Type not recorded
No type recorded · USCGC LIBERTY (WPB 1334) · USCG Arctic District (CGD-A) · Activity 7765123
31 May 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7702205
25 May 2022 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7458976
17 May 2022 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7453370
13 June 2021 Type not recorded
No type recorded · USCGC BAILEY T. BARCO (WPC 1122) · USCG Arctic District (CGD-A) · Activity 7243712
25 May 2021 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7207435
26 May 2020 COI Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6968425
5 June 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6705141
5 June 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6437281
20 April 2018 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6396005
23 May 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6175248
17 May 2016 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5902371
29 March 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5842469
29 May 2014 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4891777
2 June 2012 Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 4331846
2 June 2012 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4334043
22 May 2012 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4340783
12 May 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3547997
20 April 2009 Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3456982
13 May 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3235123
15 May 2007 Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2975017
19 April 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2922573
9 May 2006 Annual Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2693232
3 August 2005 Initial Certification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2450184
28 April 2005 Internal Structural Exam · Construction Oversight · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2344759

Deficiency record · 41

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 31 May 2023 Resolved
All machinery ventilation louvers must have the ability to be secured in th event of an emergency. Both of the machinery space louvers do not secure all the way.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 1 June 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 May 2022 Resolved
Each portable fire extinguisher on a vessel must be of approved type. Vessel's 10:BC fire extinguisher is empty and indicated "RECHARGE." Recharge or replace fire extinguisher. 46CFR181.500
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2022
Resolution: Replaced portable fire extinguisher in-kind.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 May 2022 Resolved
Six hand red flare distress signals required for oceans route. Vessel had four hand red flares. Vessel corrected on the spot with two additional red flares. 46CFR180.68
Action required: 10 - Deficiency Rectified
Resolved 25 May 2022
Resolution: Corrected on the spot.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 June 2018 Resolved
The automatic engine shutdonw test did not work with fireboys in the engine space.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2018
Resolved 5 June 2018
Resolution: The owner realized he changed the wiring and did not hook up the wiring correctly, he fixed the problem, and attended vesselt to conduct satisfactory automatic engine shutdonw test.
Construction/Loadline › Hull › Hull Plating
Issued 10 May 2018 Resolved
Vessel to make repairs to 8 spots on the bow damaged by the anchor. Vessel to make repair prior to going into the water.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 11 May 2018
Resolution: Resin was applied to 8 spots to cover damage by anchor.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 May 2017 Resolved
Provide proper stowage for child size and adult lifejackets; stow and label separately. 46 CFR 180.78
Due 1 June 2017
Resolved 30 May 2017
Resolution: Verified proper stowage and labeling. //s// [name withheld], CWO4
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 23 May 2017 Resolved
Provide proper lights on lifejackets per oceans route. Limited to 10 pax on limited coastwise route. 46 CFR 180.71
Due 25 May 2017
Resolved 30 May 2017
Resolution: Verified adequate amount of serviceable lights attached to lifejackets. //s// [name withheld], CWO4
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 17 May 2016 Resolved
Provide pre employment test results prior to placing crew in safety sensitive positions
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 19 May 2016
Resolution: results provided.
Communications › Visual Communication › Signalling Lamp
Issued 17 May 2016 Resolved
Provide visual alarm indicator for engine room bilge high level alarm.
Condition: Improper/Lack of Maintenance
Due 27 May 2016
Resolved 17 June 2016
Resolution: resolved.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 May 2016 Resolved
Provide proof of EAP supervisor training.
Condition: Improper/Lack of Maintenance
Due 17 June 2016
Resolved 19 May 2016
Resolution: proof provided.
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2016 Resolved
Renew retroreflective material on life buoy.
Condition: Improper/Lack of Maintenance
Due 17 June 2016
Resolved 19 May 2016
Resolution: completed.
Engineering › Bilge Water Management System › Pump
Issued 17 May 2016 Resolved
Provide portable bilge pump capable of dewatering forepeak space.
Condition: Improper/Lack of Maintenance
Due 17 June 2016
Resolved 19 May 2016
Resolution: provided.
Engineering › Bilge Water Management System › Piping
Issued 17 May 2016 Resolved
Provide 2 hose clamps for each hose bilge hose connection in the engine room and forepeak.
Condition: Improper/Lack of Maintenance
Due 17 June 2016
Resolved 19 May 2016
Resolution: provided.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 May 2016 Resolved
Provide remote emergency fuel shut off valve for the diesel stove fuel supply and mark valve location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Resolution: provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 May 2016 Resolved
Provide a current copy of the coast pilot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 19 May 2016
Resolution: provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 May 2016 Resolved
Provide proo on radio telephony cert that the vessel meets fcc rules for an oceans route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Resolution: provided.
Construction/Loadline › Hull › Hull Plating
Issued 2 June 2012 Resolved
Vessel grounded in vicinity of Port Ashton. Claims no hull damage, only prop damage. Vessel issued no sail 835.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2012
Resolved 3 June 2012
Resolution: Minimal hull damage was discovered on two places on the keel near the bow. This damage was faired out and reglassed. The stbd shaft and prop were pulled and changed out with new ones.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 May 2009 Resolved
Provide 2ea alcohol test kits
Action required: 705 - Other - as specified
Due 22 June 2009
Resolved 20 May 2009
Resolution: O/O provided test kits
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 May 2009 Resolved
Provide crew for drills & operational test of vessel
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 20 May 2009
Resolution: Crew drills performed
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 12 May 2009 Resolved
Prove operation of smoke detector in passenger berthing
Action required: 705 - Other - as specified
Due 21 May 2009
Resolved 20 May 2009
Resolution: Smoke detector tested
Stability › Unintentional Flooding › General
Issued 21 April 2009 Resolved
provide positive shutoff valve on all bilge pump overboard discharges as close to hull penetration as possible, IAW 46CFR 182.520(e)(7).
Due 21 May 2009
Resolved 12 May 2009
Lifesaving › Hand Flares › Expired
Issued 13 May 2008 Resolved
Replace 03 orange smoke flares.
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 24 June 2008
Resolution: O/O provided receipts for purchase of orange smoke flares. Cleared 835, verified while attending vsl for drills on 06Oct08.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 13 May 2008 Resolved
Mark emergency escape hatch.
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 24 June 2008
Resolution: O/O attended Sector Anchorage to provide documentation for 835 corrections. Verbally attested that emergency escape hatch had been properly marked. Cleared 835. Verified on 06Oct08 while attending the vsl for drills.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 May 2008 Resolved
Provide crew for drills.
Action required: 705 - Other - as specified
Resolved 6 October 2008
Resolution: Vessel provided crew and completed drills to satisfaction of attending marine inspector.
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 13 May 2008 Resolved
Show proper start/functioning of stbd MDE. Would not start during inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2008
Resolution: MDE was fixed after loose ground wire on starter was secured.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 May 2007 Resolved
Replace/repair fwd masthead light
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 5 June 2007
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 15 May 2007 Resolved
03 additional smoke flares & 03 handheld red flares are required
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 16 May 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 15 May 2007 Resolved
Make operable port fuel shut-off
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 16 May 2007
Documentation › Logs/Records › Logbook (official)
Issued 15 May 2007 Resolved
Provide ships log
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 16 May 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 15 May 2007 Resolved
A-2 or B-1 fire extinguisher requires
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 16 May 2007
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 15 May 2007 Resolved
Replace raft hydrostatic release
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 16 May 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 May 2007 Resolved
provide proof of negative drug test
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 5 June 2007
Electrical › Electric Generation Source (service) › Power Requirement
Issued 9 May 2006 Resolved
Replace damaged portside battery combiner
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 23 May 2006
Resolution: Batter combiner replaced
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 May 2006 Resolved
Stencil vessels name on ringbouy & lifejackets
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 23 May 2006
Resolution: Vessels name stenciled on lifejackets & ring bouy
Stability › Watertight Integrity › Weathertight Enclosure
Issued 9 May 2006 Resolved
Provide captive chain for FWD hatch
Action required: 705 - Other - as specified
Due 12 May 2006
Resolved 23 May 2006
Resolution: Captive chain attached to FWD hatch
Documentation › Logs/Records › Drug Test Records
Issued 3 August 2005 Resolved
Provide documentation of crew participation in chemical test program.
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 9 May 2006
Personnel › Training › First Aid/CPR
Issued 3 August 2005 Resolved
Provide documentation of Crew first aid/CPR certification
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 9 May 2006
Documentation › Markings/Placards › Warning Signs
Issued 3 August 2005 Resolved
Lable forward emergency escape hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2006
Resolved 9 May 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 August 2005 Resolved
Provide battery for float light to life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2006
Resolved 9 May 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 August 2005 Resolved
Provide corrosion resistant clip for attachment of float light to life ring.
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 9 May 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 August 2005 Resolved
Provide high water bilge alarms for lazarette and storage space forward of engine room. Alarms must have audible and visual indicator at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2006
Resolved 9 May 2006

Casualty record · 1

2 June 2012Routine · role: Involved in a Marine Casualty · activity 4334043
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record