Records from 2009 to 2026. Most recent: inspection, 7 January 2026.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 16.0 ft × 7.0 ft
Registered tonnagegross 42 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALLSTATE ENVIRONMENTAL DREAGING INC · SNEAD'S FERRY, NC, UNITED STATES · built 2005
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portCAPE MAY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Simplified, Gross Ton
33 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
7 January 2026
Administrative Inspection · Examination of Repairs · Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8290853
20 November 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8269748
28 February 2025
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8086058
21 November 2024
Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8036368
26 September 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7798446
5 July 2022
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7496626
4 February 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7390895
6 October 2021
Deficiency Check · Initial Certification · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7327501
7 July 2021
Initial Certification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7247915
31 March 2021
TPO Audit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7185704
4 January 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7119493
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505676
26 September 2013
Industry Initiated Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4779495
6 July 2011
Industry Initiated Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4072380
29 December 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3656470
6 February 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3414564
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 November 2025
Resolved
Each towing vessel must be equipped with navigation
lights, shapes, and sound signals in accordance with the
International Regulations for Prevention of Collisions
at Sea (COLREGS) or 33 CFR part 84 as appropriate to its
area of operation. All three mast lights were missing
bulbs and not operable during inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2025
Resolved 20 November 2025
Resolution: Operator replaced bubls and proved operation of mast lights to the satisfaction of MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 November 2025
Resolved
The master must ensure that all hatches, doors, and
other openings designed to be watertight or weather tight function properly. Stbd galley watertight door has
gap in gasket and allows light to come in when dogged
down. Replace gasket to ensure door is watertight to the
satisfaction of attending MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 24 November 2025
Resolution: MI reviewed and approved photos and video provided by operator of new gasket installed on galley door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 November 2025
Resolved
The following systems must be equipped with gauges at
the machinery location:(1) Main engine lubricating oil
pressure and main engine RPM; (2) Main engine cooling
water temperature; (3) Auxiliary generator engine
lubricating oil pressure and auxiliary generator engine
RPM. Vessels auxiliary generator RPM gauge was
inoperable. Fix RPM Gauge to the satisfaction of MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 4 December 2025
Resolution: Operator provided pictures of tachometer in place and operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2025
Resolved
If Nonmetallic flexible hose is acceptable if it: Is
used in lengths of not more than 30 inches; (ii) Is
visible and easily accessible; (iii) Does not penetrate
a watertight bulkhead; (iv) Is fabricated with an inner
tube and a cover of synthetic rubber or other suitable
material reinforced with wire braid; If designed for use
with compression fittings, is fitted with suitable,
corrosion-resistant, or fittings compliant with the SAE
J1475. Port and Stbd main engines have worn hydraulic
hoses coming off of reduction gear, Replace hoses to
comply with SAE J1942 to satisfaction of MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 4 December 2025
Resolution: Oerator has provided documentation showing all deficient hydraulic hoses have been replaced.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 20 November 2025
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards... Operators utilize pump in the forward space to transfer fuel to deck equipment. During the transfer, a person is in the confined space in order to shut the valve in case of emergency and the closest extinguishers are on the bridge/galley. Review the health and safety plan and identify if any changes should be made to make the evolution safer for the individuals involved. Submit plan to the Coast Guard for review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2025
Resolved 4 December 2025
Resolution: operator has reviewed SMS and updated procedures to the satisfactory of attending MI
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 November 2025
Resolved
Each towing vessel must have either a self-priming,
power-driven, fixed fire pump, a fire main, and hoses
and nozzles in accordance with paragraphs (a) through
(d) of this section; or a portable pump, and hoses and
nozzles, in accordance with paragraphs (e) and (f) of
this section. Fire hose was found with pinholes in it
during operation. Operator provided vessel with new hose
and attending MI corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 20 November 2025
Resolved 20 November 2025
Resolution: Operator provided vessel with new hose
and attending MI corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 November 2025
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards.
Oil was found accumulated and pooled at the bottom of
both battery enclosures within the engine room.
Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 20 November 2025
Resolved 20 November 2025
Resolution: Mate removed oil and cleaned battery enclosures on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2024
Resolved
MI observed fuel tank sight glass was made of plastic tubing
vessel is required to replace plastic sight glass with a tempered glass with a guard to the satisfactory of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2024
Resolved 28 February 2025
Resolution: vsl installed new/ proper sightglass for f/o tank.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2024
Resolved
MI observed stbd engine fuel oil return flexible hose was dry rotted.
vessel is required to replace hose that complies with SAE J1942 to the satisfactory of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2024
Resolved 11 December 2024
Resolution: replaced hose
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2024
Resolved
MI observed the portable air compressor being used to power ships horn was connected to an extension cord.
Vessel is required to make permanent installation to air compressor and its electrical power to the satisfactory of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2024
Resolved 11 December 2024
Resolution: hard wired compressure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 November 2024
Resolved
MI observed the directional control valve for steering had exposed connections.
Vessel is required to properly cover exposed connections to the satisfactory of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2024
Resolved 11 December 2024
Resolution: installed cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 November 2024
Resolved
MI observed the generator in engine room did not have local gauges. (lube oil pressure) (RPM) (Cooling water temp)
Vessel is required to install all three gauges at the machinery location to the satisfactory of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2024
Resolved 19 December 2024
Resolution: Rpm, l/o pressure and cooling water temp gauges installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 November 2024
Resolved
MI observed the power operated hydraulic steering system had an unreadable pressure gauge.
Vessel is required to replace pressure gauge to the satisfactory of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2024
Resolved 11 December 2024
Resolution: replaced gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 August 2021
Resolved
Air tanks and pumps were not properly mounted. Ensure equipment is properly mounted and secured for sea/transit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2021
Resolved 6 October 2021
Resolution: Attained vsl, tank was properly mounted/tac welded.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: Invalid MMSI and is not broadcasting a Call Sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 October 2021
Resolution: Attained vsl, AIS was broadcasting properly, sending and receiving. Capt also was able to change vsl statue too,