Records from 2008 to 2026. Most recent: inspection, 24 April 2026.
Inspection history · 21
24 April 2026
Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8352971
8 September 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8229526
6 September 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8230250
6 June 2025
Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8153389
10 April 2025
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8109416
19 July 2024
Simplified Stability Test
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7964447
10 July 2024
Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7954822
27 June 2024
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7943351
10 July 2023
Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7732064
24 March 2023
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7656102
14 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7506309
29 March 2021
Deficiency Check · COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7164556
15 June 2020
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6976989
21 May 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6689391
8 April 2019
Internal Structural Exam · Hull Examination · Drydock Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6659111
8 June 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6442135
8 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6408768
26 March 2018
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6378494
16 May 2017
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6147149
7 April 2016
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5849488
21 March 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5837703
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 June 2025
Resolved
A vessel on an oceans route must carry six hand red flare distress signals and six hand orange smoke distress signals, in lieu of the orange smoke signal a vessel may carry six additional red flare distress signals. The vessel is missing one red flare.
(46 CFR 180.68)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 16 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2025
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050. The grab line on the ring buoy is deteriorated due to dry rot.
(46 CFR 180.70)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 6 June 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 June 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in ISO 18813, or a kit with equivalent contents.
The existing kit does not have the proper inventory of burn preparations.
(46 CFR 184.710)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 9 June 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 July 2024
Resolved
The vessel is required to have an alcohol testing device on board to enable testing of the crew in the event of a serious marine incident; the existing test swabs are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 22 July 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 July 2024
Resolved
A pre-engineered fixed gas fire fighting system must have an audible alarm that sounds upon activation located at the operating station; the audible alarm is not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 16 August 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 July 2024
Resolved
The name of the vessel must be marked on the port and stbd bow in 4" letter; the port side is not so marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2024
Resolved 22 July 2024
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 27 June 2024
Resolved
Stability information (stability details indicated on a stability letter) is required on vessels to allow the master to be able to determine operating guidelines, loading restrictions, and ensure compliance with the applicable intact and damage stability regulations of
46 CFR Part 178. Repairs to the vessel in which the vertical center of gravity of the main engines increased by greater than 3 inches resulting in a change to the stability characteristics of the vessel, accordingly, the simplified stability test results must be confirmed. The vessel is reduce to a Limited Coastwise (partially protected) route until the stability information is updated and confirmed.
46 CFR 178.210
Action required: 705 - Other - as specified
Resolved 19 July 2024
Resolution: New SST witnessed and passed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 July 2023
Resolved
A vessel of at least 26 feet in length must be provided with a visual and audible alarm, at the operating station, which indicates high water level in required spaces; the visual indicator for the forward void space is not working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 2 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 July 2023
Resolved
Each life float must meet the specifications in accordance with the approval number 160.027; the paint on the life floats is faded and not in compliance with the specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 14 July 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 March 2023
Resolved
A hatch exposed to the weather must be water tight; the gasket on the forepeak hatch is loose and deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2023
Resolved 10 July 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 July 2022
Resolved
Each life float must have Type II reflective material meeting subpart 164.018 of this chapter on each side and each end; existing life floats retro tape is deteriorated and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 July 2022
Resolved 14 July 2022
Resolution: Corrected on site.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 14 July 2022
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every five years; vessel’s Safety Radio Certificate is expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 15 August 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 July 2022
Resolved
Vessel must have Crew Training Program in place consisting of fire safety requirements of 185.420 (b); the program has not been implemented.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 28 July 2022
Resolved 25 July 2022
Resolution: .
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2021
Resolved
Fuses must be of the cartridge type and listed by UL; the fuse panel under the operating console is a blade type fuse block.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2021
Resolved 15 July 2021
Resolution: A new cartridge type panel was installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2019
Resolved
The alcohol test swabs are expired; provide vessel with up-to-date test swabs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 May 2019
Resolved
The first aid kit is not equipped with the proper quantity of aspirin; provide additional aspirin to insure proper inventory.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2019
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 21 May 2019
Resolved
The audible alarm for the fixed fire fighting system is not functioning, the system is otherwise operational; repair or replace the audible alarm as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2019
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 May 2017
Resolved
Provide proof of COD for the vessel.
Due 15 June 2017
Resolved 1 June 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 May 2017
Resolved
Provide the vessel with a current US Coast Pilot.
Due 15 June 2017
Resolved 1 June 2017
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 16 May 2017
Resolved
Provide the vessel with the local notice to mairners.
Due 15 June 2017
Resolved 1 June 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2017
Resolved
Repair the anchor light as needed.
Due 15 June 2017
Resolved 1 June 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 May 2017
Resolved
Repair or replace the BII fie extinguisher bracket.
Due 15 June 2017
Resolved 1 June 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 16 May 2017
Resolved
Repair the vent closures for the engine compartment to ensure proper seal.
Due 15 June 2017
Resolved 1 June 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 16 May 2017
Resolved
Provide proof of maintenance (service report) for the fixed fire fighting system.
Due 15 June 2017
Resolved 1 June 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 12 April 2016
Resolved
The vessel has a class "D" DSC capable radio, current FCC regulations require a class "A" VHF radio. The operator must upgrade to a DSC capable class "A" VHF radio or submit an application for a waiver to the FCC.
Due 12 October 2016
Resolved 16 May 2017
Lifesaving › Lifefloat › Markings
Issued 12 April 2016
Resolved
The port life float is faded, restore the float to the original color.
Due 11 May 2016
Resolved 2 May 2016
Resolution: Life float has been painted with an approved type paint.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 April 2016
Resolved
The ammonia inhalant in the first aid kit is expired, replace product as needed.
Due 11 May 2016
Resolved 12 April 2016
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 April 2016
Resolved
Provide a means for tracking the dates on which the water light batteries are replaced.
Due 11 May 2016
Resolved 13 April 2016
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 12 April 2016
Resolved
Provide and document the required EAP training for the crew and the additional one hour supervisor training.
Due 11 May 2016
Resolved 11 May 2016