LOWLANDS MAINE

LOWLANDS MAINE is a 2005 freight ship. The Coast Guard has recorded 22 inspections since 2005, most recently in June 2021, along with 16 deficiencies and 5 operational controls.

Records from 2005 to 2021. Most recent: inspection, 24 June 2021.

Built
2005
Last inspected
24 June 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9304239 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
741783
Flag
PANAMA
—
Maury page id
psix-741783

Inspections, by type

…with no type recorded8
Years with a record 10 calendar years (2005–2021)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it76784 - Dead Weight, Metric Ton
87409 - Displacement, Metric Ton
40039 - Convention (Subpart B), Gross Ton
25259 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

24 June 2021 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7222401
16 June 2021 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7227651
16 June 2021 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7231577
22 November 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7097739
18 November 2020 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7097694
18 November 2020 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7099447
22 June 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6976002
8 February 2020 Deficiency Check · PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6897071
19 July 2018 Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6474763
4 December 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6317513
2 August 2011 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4101763
7 September 2010 PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex VI Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3849256
10 May 2008 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3203208
7 November 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3093834
11 June 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2956883
5 August 2006 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2736446
27 March 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2610128
25 March 2006 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2610075
24 March 2006 ISPS I Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2608811
21 March 2006 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2606621
2 April 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2321670
2 April 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2325235

Deficiency record · 16

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2021 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed improper cooling jacket bolts installed on the main engine which are not to manufaturers specifications. 74 SOLAS (04) II-1/26.1
Action required: 60 - Rectify deficiencies prior to movement
Due 23 July 2021
Resolved 24 June 2021
Resolution: Received, reviewed, and accepted Class NK Survey Report. Improper bolts were replaced with original spares onboard. Confirmed proper gap / spacing between bolt and jacket cover to be maintained properly for all cylinders.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 24 June 2021 Resolved
All arrangement used for pilot transfer shall efficiently fulfil their purpose of enabling pilots to embark and disembark safely. Starboard accomadation ladder stanchion supports were coroded through. 74 SOLAS (14) V/23.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2021
Resolved 24 June 2021
Resolution: Received, reviewed, and accepted Class NK Survey Report. (15) Stanchion sockets for starboard accomodation ladder and (05) for the port side ladder were replaced with new sockets made by ship's crew. Condition of class for permanent repair NLT 23AUG21.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 24 June 2021 Resolved
In spaced where penetration of oil products is possible, the surface insulation shall be impervious to oil. PSCO observed oil soaked lagging on the fuel oil return line. 74 SOLAS (04) II-2/4.3
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2021
Resolved 24 June 2021
Resolution: Received, reviewed, and accepted Class NK Survey Report. The oil soaked lagging on the M/E fuel oil return line was renewed. No leak of fuel oil from the piping.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020 Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. THE FUEL OIL PUMP ON THE #2 GENERATOR WAS FOUND TO BE EXCESSIVELY LEAKING, EFFECTIVELY SOAKING ALL SURROUNDING PIPE INSULATION AND CREATING A POOL OF OIL BELOW THE GENERATOR. SOLAS 74 (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020 Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. EXCESSIVE POOLING OF FUEL OIL WAS FOUND THROUGHOUT THE MAIN ENGINE CYLINDER HOUSING AREA, FILLING COMPONENT SEAMS, COATING HORIZONTAL SURFACES, AND CONTINUING TO RUN DOWN THE ENGINE SIDES TO LEVELS BELOW. SOLAS 74 (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020 Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. THE DOUBLE JACKETED FUEL INJECTOR LINES LEADING TO THE #5 CYLINDER WERE FOUND TO BE LEAKING EXCESSIVELY TO THE POINT WHERE FUEL OIL WAS DRIPPING OFF THE BRAIDED METAL SHEAVING. SOLAS 74 (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020 Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. EXCESSIVE OILY RAGS FOUND THROUGHOUT ENGINEROOM, UNDER GENERATOR, ON THE MAIN ENGINE, AND THROUGHOUT THE FUEL PURIFIER FLATS, WHICH PRESENTS A SIGNIFICANT FIRE HAZARD AND DANGER TO THE SHIP AND ITS CREW. SOLAS 74 (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020 Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. EXCESSIVE LEAKAGE FROM ALL FITTINGS WAS FOUND ON THE #2 FUEL OIL PURIFIER RESULTING IN OIL SOAKED INSULATION ON ALL ASSOCIATED PIPING. IN ADDITION, A CREW-ENGINEERED FUNNEL-STRAINER APPARATUS WAS FOUND INSTALLED ON THE #2 FUEL OIL PIPING. SOLAS 74 (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020 Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. EXCESSIVE LEAKAGE WAS OBSERVED FROM ALL CONNECTIONS AND FITTINGS ON THE NUMBER 2 FUEL OIL HEAT EXCHANGER MANIFOLD RESULTING IN OIL SOAKED INSULATION ON ALL ASSOCIATED PIPING, THUS CREATING A SERIOUS FIRE HAZARD AND PRESENTING A CLEAR DANGER TO THE SHIP AND ITS CREW. SOLAS 74 (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020 Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. THE #1 FUEL OIL CIRCULATION PUMP WAS FOUND TO BE EXCESSIVELY LEAKING FROM THE MECHANICAL SEAL. ADDITIONALLY A COFFEE CAN WAS UTILIZED TO COLLECT THE FUEL OIL WITH FUEL OIL COATING THE SURROUNDING AREA. SOLAS 74 (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020 Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. OIL LEAKAGE FROM THE GENERATORS AND FUEL OIL PURIFIER FLATS PERMEATED THROUGH DECK OPENINGS WHICH SATURATED THE CABLE RUNS BELOW CONTAINING UP TO 7 ELECTRICAL CABLES. SOLAS 74 (2004) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 February 2020 Resolved
HE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVSIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE #1 FIRE AND GENERAL SERVICE PUMP WAS FOUND TO BE LEAKING A CONTINUOUS STREAM OF SALT WATER DURING OPERATION. SOLAS 74 (2014) I/11a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 8 February 2020 Resolved
AFTER ANY SURVEY OF THE SHIP NO CHANGE SHALL BE MADE TO THE EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY. MODIFICATIONS TO THE PIPING OF THE OILY WATER SEPERATOR HAVE BEEN MADE WITHOUT DOCUMENTATION OF CLASS APPROVAL. SOLAS 74 (2014) I/11b
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 February 2020
Resolved 11 February 2020
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. MSU Portland conducted an onboard verification to confirm the deficiencies were rectified to the satisfaction of the COTP.
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 4 December 2017 Resolved
0940 - In order to discharge ballast water in the waters of the United States, the vessel must use a Ballast Water Management System (BWMS) type approved by the US Coast Guard, use an Alternate Management System (AMS), or use ballast with water from the US Public Water System (PWS) according to the schedule in paragraph (b) of this section.This existing vessel, keel laid in 2004, with a ballast capacity of 37664 cubic meters, dry-docked in DECEMBER 2016 has passed its compliance date and has not installed a BWMS or AMS. Prior to discharging untreated ballast water in the waters of the United States, the vessel must comply with one of the approved ballast water management methods listed in 33 CFR 151.2035(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 19 July 2018
Resolution: Received, Reviewed and accepted Special Note from CG-OES that extended the Ballast Water Expiry Date to 03JUL20.
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 4 December 2017 Resolved
0940 - A vessel equipped with ballast water tanks that operates in the waters of the United States must maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's ballast water management strategy and comply with the requirements of this subpart. Vessels ballast water management plan does not include all of the necessary provisions listed in 33CFR 151 Subpart D. Vessel’s ballast water management plan must include the provisions listed in 33 CFR 151.2050(g).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 January 2018
Resolved 19 July 2018
Resolution: Received, reviewed and accepted ammendments to the Ballast Water Management Plan and determined to be satisfactory.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 August 2006 Resolved
RECEIVED FAX REGARDING VESSEL SEARCH AND RESCUE TRANSPONDER NOT FUNCTIONING. REPAIR HAS BEEN ARRANGED IN THIS PORT.
Action required: 705 - Other - as specified
Due 13 August 2006
Resolved 7 August 2006
Resolution: recieved copy of the reciept from the ship attesting to the repair of the SART.