LOWLANDS MAINE is a 2005 freight ship. The Coast Guard has recorded 22 inspections since 2005, most recently in June 2021, along with 16 deficiencies and 5 operational controls.
Records from 2005 to 2021. Most recent: inspection, 24 June 2021.
- Built
- 2005
- Last inspected
- 24 June 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9304239 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
H9JU
741783
Flag
PANAMA
—
Maury page id
psix-741783
Inspections, by type
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it76784 - Dead Weight, Metric Ton
87409 - Displacement, Metric Ton
40039 - Convention (Subpart B), Gross Ton
25259 - Convention (Subpart B), Net Ton
87409 - Displacement, Metric Ton
40039 - Convention (Subpart B), Gross Ton
25259 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
24 June 2021
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7222401
16 June 2021
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7227651
16 June 2021
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7231577
22 November 2020
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7097739
18 November 2020
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7097694
18 November 2020
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7099447
22 June 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6976002
8 February 2020
Deficiency Check · PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6897071
19 July 2018
Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6474763
4 December 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6317513
2 August 2011
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4101763
7 September 2010
PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex VI Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3849256
10 May 2008
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3203208
7 November 2007
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3093834
11 June 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2956883
5 August 2006
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2736446
27 March 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2610128
25 March 2006
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2610075
24 March 2006
ISPS I Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2608811
21 March 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2606621
2 April 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2321670
2 April 2005
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2325235
Deficiency record · 16
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2021
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed improper cooling jacket bolts installed on the main engine which are not to manufaturers specifications.
74 SOLAS (04) II-1/26.1
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 24 June 2021
Resolved
All arrangement used for pilot transfer shall efficiently fulfil their purpose of enabling pilots to embark and disembark safely. Starboard accomadation ladder stanchion supports were coroded through.
74 SOLAS (14) V/23.2.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 24 June 2021
Resolved
In spaced where penetration of oil products is possible, the surface insulation shall be impervious to oil. PSCO observed oil soaked lagging on the fuel oil return line.
74 SOLAS (04) II-2/4.3
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. THE FUEL OIL PUMP ON THE #2 GENERATOR WAS FOUND TO BE EXCESSIVELY LEAKING, EFFECTIVELY SOAKING ALL SURROUNDING PIPE INSULATION AND CREATING A POOL OF OIL BELOW THE GENERATOR. SOLAS 74 (2004) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. EXCESSIVE POOLING OF FUEL OIL WAS FOUND THROUGHOUT THE MAIN ENGINE CYLINDER HOUSING AREA, FILLING COMPONENT SEAMS, COATING HORIZONTAL SURFACES, AND CONTINUING TO RUN DOWN THE ENGINE SIDES TO LEVELS BELOW. SOLAS 74 (2004) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. THE DOUBLE JACKETED FUEL INJECTOR LINES LEADING TO THE #5 CYLINDER WERE FOUND TO BE LEAKING EXCESSIVELY TO THE POINT WHERE FUEL OIL WAS DRIPPING OFF THE BRAIDED METAL SHEAVING. SOLAS 74 (2004) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. EXCESSIVE OILY RAGS FOUND THROUGHOUT ENGINEROOM, UNDER GENERATOR, ON THE MAIN ENGINE, AND THROUGHOUT THE FUEL PURIFIER FLATS, WHICH PRESENTS A SIGNIFICANT FIRE HAZARD AND DANGER TO THE SHIP AND ITS CREW. SOLAS 74 (2004) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. EXCESSIVE LEAKAGE FROM ALL FITTINGS WAS FOUND ON THE #2 FUEL OIL PURIFIER RESULTING IN OIL SOAKED INSULATION ON ALL ASSOCIATED PIPING. IN ADDITION, A CREW-ENGINEERED FUNNEL-STRAINER APPARATUS WAS FOUND INSTALLED ON THE #2 FUEL OIL PIPING. SOLAS 74 (2004) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. EXCESSIVE LEAKAGE WAS OBSERVED FROM ALL CONNECTIONS AND FITTINGS ON THE NUMBER 2 FUEL OIL HEAT EXCHANGER MANIFOLD RESULTING IN OIL SOAKED INSULATION ON ALL ASSOCIATED PIPING, THUS CREATING A SERIOUS FIRE HAZARD AND PRESENTING A CLEAR DANGER TO THE SHIP AND ITS CREW. SOLAS 74 (2004) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. THE #1 FUEL OIL CIRCULATION PUMP WAS FOUND TO BE EXCESSIVELY LEAKING FROM THE MECHANICAL SEAL. ADDITIONALLY A COFFEE CAN WAS UTILIZED TO COLLECT THE FUEL OIL WITH FUEL OIL COATING THE SURROUNDING AREA. SOLAS 74 (2004) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 February 2020
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. OIL LEAKAGE FROM THE GENERATORS AND FUEL OIL PURIFIER FLATS PERMEATED THROUGH DECK OPENINGS WHICH SATURATED THE CABLE RUNS BELOW CONTAINING UP TO 7 ELECTRICAL CABLES. SOLAS 74 (2004) II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 February 2020
Resolved
HE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVSIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. THE #1 FIRE AND GENERAL SERVICE PUMP WAS FOUND TO BE LEAKING A CONTINUOUS STREAM OF SALT WATER DURING OPERATION. SOLAS 74 (2014) I/11a
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 8 February 2020
Resolved
AFTER ANY SURVEY OF THE SHIP NO CHANGE SHALL BE MADE TO THE
EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY. MODIFICATIONS TO THE PIPING OF THE OILY WATER SEPERATOR HAVE BEEN MADE WITHOUT DOCUMENTATION OF CLASS APPROVAL. SOLAS 74 (2014) I/11b
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 4 December 2017
Resolved
0940 - In order to discharge ballast water in the waters of the United States, the vessel must use a Ballast Water Management System (BWMS) type approved by the US Coast Guard, use an Alternate Management System (AMS), or use ballast with water from the US Public Water System (PWS) according to the schedule in paragraph (b) of this section.This existing vessel, keel laid in 2004, with a ballast capacity of 37664 cubic meters, dry-docked in DECEMBER 2016 has passed its compliance date and has not installed a BWMS or AMS. Prior to discharging untreated ballast water in the waters of the United States, the vessel must comply with one of the approved ballast water management methods listed in 33 CFR 151.2035(a).
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 4 December 2017
Resolved
0940 - A vessel equipped with ballast water tanks that operates in the waters of the United States must maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's ballast water management strategy and comply with the requirements of this subpart. Vessels ballast water management plan does not include all of the necessary provisions listed in 33CFR 151 Subpart D. Vessel’s ballast water management plan must include the provisions listed in 33 CFR 151.2050(g).
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 August 2006
Resolved
RECEIVED FAX REGARDING VESSEL SEARCH AND RESCUE TRANSPONDER NOT FUNCTIONING. REPAIR HAS BEEN ARRANGED IN THIS PORT.