← All vessels
ABI C
Offshore Supply Vessel · Offshore class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named ABI C
ABI C is a 2005 offshore supply vessel. The Coast Guard has recorded 20 inspections since 2004, most recently in March 2026, along with 30 deficiencies.
Records from 2004 to 2026. Most recent: inspection, 11 March 2026.
- Built
- 2005
- Last inspected
- 11 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 30 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1169236
9370692 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH2939
742075
Flag
UNITED STATES
367602710
Maury page id
psix-742075
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)130.6 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)130.6 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 447 / net 134
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2005
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 December 2025 · expires 31 January 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
447 - Convention (Subpart B), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
134 - Convention (Subpart B), Net Ton
447 - Convention (Subpart B), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
134 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH2939MMSI 367602710 · active · compulsorily equipped · granted 18 November 2023, expires 22 January 2034
WDC5738MMSI 367045740 · expired · voluntarily equipped · granted 28 May 2005, cancelled 1 August 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
11 March 2026
Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8316406
5 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8088516
1 February 2024
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7853935
30 November 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7824872
8 February 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7633192
6 December 2021
Cargo Tank Internal · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7363302
8 November 2021
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7347698
9 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7152318
3 March 2020
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6919452
12 July 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6747147
16 January 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6610783
2 November 2018
Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6573437
13 March 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6371973
7 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6100543
7 November 2016
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6037040
2 May 2016
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5867931
19 June 2008
Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3241218
16 August 2006
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2749892
15 June 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2391331
23 September 2004
Cargo Tank Internal · Hull Examination · Plan Review (Other than "T") · MTSA Verification · Construction Oversight · Internal Structural Exam · Initial Construction-Excluding Oversight · Deficiency Check · Welding Related Inspections Qualification Testing · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2385253
Deficiency record · 30
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 5 March 2025
Resolved
Video and audio surveillance equipment must be placed in passageways into which doors from which staterooms open. Surveillance equipment not installed, a quote was available but not an invoice, work order or contract. 46 USC 4901
A plan was submitted to have the equipment installed NLT 01APR2025. An invoice was provided. Next job is scheduled for 09 total persons onboard. Updated the control action from 17 c to 50 c with the due date 01APR2025.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 November 2021
Resolved
Each FCC document must have official number. Station license, Bridge to Bridge and radio telephony had wrong official number. Re-issue FCC documents with correct official number to match the COI.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 March 2020
Resolved
A vessel must be fitted with ground tackle necessary for the vessel to be safely anchored. The Anchor chain was wasted approximately 20% of that which was originally accepted by the OCMI.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 March 2020
Resolved
Vessel must carry adequate and up-to-date charts for intended voyage. Vessel operates out of Port Fourchon, the last update was 2008.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2020
Resolved
Safety relief valves on UPVs were missing the inspection tag. VSL attempted to test the set pressure on the valves without success. Safety relief valve shall be tested and set not the exceed MAWP of the pressure VSL.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2020
Resolved
Steering System must comply with section 130.140. Steering ram hydraulic valve on back deck port side leaking. Fix or replace valve and remove fluid to ensure that it does not spill into the water.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 3 March 2020
Resolved
Watertight doors in a bulkhead must be properly labeled. Watertight door leading to the deck from the engine room is not properly labeled as an emergency escape.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 March 2020
Resolved
When emergency repairs are made machinery or equipment the master or the operator must notify the Local OCMI and make permanent to the satisfaction of the attending USCG Marine inspector. Bilge piping STBD side engine room had temporary repairs.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 January 2019
Resolved
Emergency instructions in engine room should be posted in the engine room as well as the pilot house.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 January 2019
Resolved
Sound powered phone in engine room inoperable (corrected before the end of the inspection)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2019
Resolved
Fuel hose on starboard generator not approved type, should be replaced with nonmetalic fuel hose.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 January 2019
Resolved
Switchboard in engine room missing lights and light covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 January 2019
Resolved
Check valve needs replaced on port air compressor
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 January 2019
Resolved
Emergency Escape door in engine rrom needs adjusted to be able to be opened by all personnel. Door is currently too tight.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 January 2019
Resolved
Emergency Escape door in engine room not properly labeled
Stability › Watertight Integrity › Weathertight Enclosure
Issued 13 March 2018
Resolved
Replace gaskets and adjust hinges on watertight door and hatch.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 13 March 2018
Resolved
Properly tag out and repair the 440 ground on main switchboard.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 March 2018
Resolved
Provide proper wiring for lighting above shafts in engine room.
Engineering › Fuel Oil Service System › Piping
Issued 13 March 2018
Resolved
Provide proper fuel return piping on generator and stbd main engine.
Engineering › Compressed Air System (start air) › Valve
Issued 13 March 2018
Resolved
Prove proper bench test for two relief valves for pressure vessels in engine room.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 March 2018
Resolved
Provide shaft guard on methanol pump.
Personnel › Training › Watchkeeping
Issued 16 August 2006
Resolved
Post Emergency Instructions for Rough Weather as per 46CFR131.340.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 16 August 2006
Resolved
Update Station Bill to include current manning.
Operations/Management › Drills/Instruction › Fire
Issued 9 June 2005
Resolved
Demonstrate crew proficiency in fire, abandonship and man overboard drills.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 June 2005
Resolved
Add chafing gear or re-route the power cables below the main switch board.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 9 June 2005
Resolved
Properly label the 12 and 24volt DC circuit breakers in the engine room.
Construction/Loadline › Structures › Door
Issued 9 June 2005
Resolved
Remove paint from the lips of all doors and ventilators and from the corresponding gaskets.
Engineering › Steering Gear System › Ram
Issued 9 June 2005
Resolved
Install proper sized bolts in all steering ram connections.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 June 2005
Resolved
Complete proper installation of all DP related cables.
Communications › Internal Communications System › Sound-powered Telephone
Issued 9 June 2005
Resolved
Repair or replace the blue sound powered call indicator light in the engine room.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.