ABI C is a 2005 offshore supply vessel. The Coast Guard has recorded 16 inspections since 2016, most recently in March 2026, along with 21 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 11 March 2026.

Built
2005
Last inspected
11 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 March 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9370692
WDH2939
742075
Flag
UNITED STATES
Maury page id
psix-742075

Documentation record

Registered dimensions (L × B × D)130.6 ft × 36.0 ft × 12.0 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)130.6 ft × 36.0 ft × 12.0 ft
ITC tonnagegross 447 / net 134
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2005
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 December 2025 · expires 31 January 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
447 - Convention (Subpart B), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
134 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

11 March 2026 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8316406
5 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8088516
1 February 2024 COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7853935
30 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7824872
8 February 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7633192
6 December 2021 Cargo Tank Internal · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7363302
8 November 2021 Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7347698
9 March 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7152318
3 March 2020 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6919452
12 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6747147
16 January 2019 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6610783
2 November 2018 Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6573437
13 March 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6371973
7 March 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6100543
7 November 2016 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6037040
2 May 2016 Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5867931

Deficiency record · 21

09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 5 March 2025 Resolved
Video and audio surveillance equipment must be placed in passageways into which doors from which staterooms open. Surveillance equipment not installed, a quote was available but not an invoice, work order or contract. 46 USC 4901 A plan was submitted to have the equipment installed NLT 01APR2025. An invoice was provided. Next job is scheduled for 09 total persons onboard. Updated the control action from 17 c to 50 c with the due date 01APR2025.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 24 March 2025
Resolution: Cameras and signs installed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 November 2021 Resolved
Each FCC document must have official number. Station license, Bridge to Bridge and radio telephony had wrong official number. Re-issue FCC documents with correct official number to match the COI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 29 December 2021
Resolution: FCC updated the vessel's Official Number in the FCC system. Radio Station license has been uploaded into docs to show compliance.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 March 2020 Resolved
A vessel must be fitted with ground tackle necessary for the vessel to be safely anchored. The Anchor chain was wasted approximately 20% of that which was originally accepted by the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2020
Resolved 10 March 2020
Resolution: MI cleared after verifing anchor chain replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 March 2020 Resolved
Vessel must carry adequate and up-to-date charts for intended voyage. Vessel operates out of Port Fourchon, the last update was 2008.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2020
Resolved 3 March 2020
Resolution: VSL obtained new charts prior to the completion of the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2020 Resolved
Safety relief valves on UPVs were missing the inspection tag. VSL attempted to test the set pressure on the valves without success. Safety relief valve shall be tested and set not the exceed MAWP of the pressure VSL.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 4 March 2020
Resolution: MI cleared issued deficiencies after reviewing photographs that were submitted by the vessel representative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2020 Resolved
Steering System must comply with section 130.140. Steering ram hydraulic valve on back deck port side leaking. Fix or replace valve and remove fluid to ensure that it does not spill into the water.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 March 2020
Resolved 3 March 2020
Resolution: VSL replaced valave prior to the completion of the inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 3 March 2020 Resolved
Watertight doors in a bulkhead must be properly labeled. Watertight door leading to the deck from the engine room is not properly labeled as an emergency escape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2020
Resolved 4 March 2020
Resolution: MI cleared issued deficiencies after reviewing photographs that were submitted by the vessel representative.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 March 2020 Resolved
When emergency repairs are made machinery or equipment the master or the operator must notify the Local OCMI and make permanent to the satisfaction of the attending USCG Marine inspector. Bilge piping STBD side engine room had temporary repairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2020
Resolved 4 March 2020
Resolution: MI cleared issued deficiencies after reviewing photographs that were submitted by the vessel representative.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 January 2019 Resolved
Emergency instructions in engine room should be posted in the engine room as well as the pilot house.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2019
Resolved 17 January 2019
Resolution: INstructions posted in engine room.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 January 2019 Resolved
Sound powered phone in engine room inoperable (corrected before the end of the inspection)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 January 2019
Resolved 16 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 January 2019 Resolved
Fuel hose on starboard generator not approved type, should be replaced with nonmetalic fuel hose.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2019
Resolved 17 January 2019
Resolution: Hose replaced of the approved type.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 January 2019 Resolved
Switchboard in engine room missing lights and light covers.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2019
Resolved 17 January 2019
Resolution: Lights and light covers added to switchboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 January 2019 Resolved
Check valve needs replaced on port air compressor
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2019
Resolved 17 January 2019
Resolution: Check valve replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 January 2019 Resolved
Emergency Escape door in engine rrom needs adjusted to be able to be opened by all personnel. Door is currently too tight.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2019
Resolved 17 January 2019
Resolution: Emergency Escape door in engine room adjusted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 January 2019 Resolved
Emergency Escape door in engine room not properly labeled
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2019
Resolved 17 January 2019
Resolution: Emergency escape door in engine room properly labeled.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 13 March 2018 Resolved
Replace gaskets and adjust hinges on watertight door and hatch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2018
Resolution: ABS Surveyor attended and verified proper installation and adjustment.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 13 March 2018 Resolved
Properly tag out and repair the 440 ground on main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 10 April 2018
Resolution: Ground was repaired to satisfaction of the Coast Guard inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 March 2018 Resolved
Provide proper wiring for lighting above shafts in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 10 April 2018
Resolution: Lighting fixture was repaired to the satisfaction of the Coast Guard inspector.
Engineering › Fuel Oil Service System › Piping
Issued 13 March 2018 Resolved
Provide proper fuel return piping on generator and stbd main engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 10 April 2018
Resolution: Proper fuel piping was provided to the satisfaction of the Coast Guard inspector.
Engineering › Compressed Air System (start air) › Valve
Issued 13 March 2018 Resolved
Prove proper bench test for two relief valves for pressure vessels in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 10 April 2018
Resolution: New relief valves were provided to the satisfaction of the Coast Guard inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 March 2018 Resolved
Provide shaft guard on methanol pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 10 April 2018
Resolution: A proper shaft guard was installed to the satisfaction of Coast Guard inspector.