MAURY USCG vessel records Sign in
← All vessels

NAVIOS TAURUS

NAVIOS TAURUS is a 2005 freight ship. The Coast Guard has recorded 20 inspections since 2005, most recently in April 2024, along with 7 deficiencies and 4 operational controls.

Records from 2005 to 2024. Most recent: inspection, 4 April 2024.

Built
2005
Last inspected
4 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9302762 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3E2361
742114
Flag
PANAMA
—
Maury page id
psix-742114

Inspections, by type

…with no type recorded5
Years with a record 11 calendar years (2005–2024)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it76596 - Dead Weight, Metric Ton
86824 - Displacement, Metric Ton
39738 - Convention (Subpart B), Gross Ton
25754 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

4 April 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7889940
29 January 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7849015
11 January 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7620325
26 January 2022 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7385900
1 November 2021 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7332969
19 May 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6418557
18 May 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6417435
11 May 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6404594
6 October 2016 Deficiency Check · ISPS II Exam · Administrative Inspection · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6015570
16 February 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3946273
9 December 2009 PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3643995
8 November 2008 ISPS I Exam · MARPOL Annex V Examination · NPV Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3356301
7 November 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3356302
1 May 2008 ISPS II Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3196297
28 April 2008 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3194819
28 March 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3172783
17 March 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam · ILO-147 Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2604162
7 April 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2329000
4 April 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2323752
3 April 2005 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2331366

Deficiency record · 7

10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 29 January 2024 Resolved
Rudder, propellor, thrust, pitch and operational mode indicators, or other means, to determine and display rudder angle, propellor revolutions the force and direction of thrust. PSCO observed port wing rudeder angle indicator ranging from 2 to 5 degrees off depending if running one one steering pump or both pumps together. Rudder angle indicator from conning position and starboard wing were both off 2 degrees starboard while amidship. Observed steering gear rudder angle indicator off by 2 degrees starboard and overshooting by 2 degrees to port. 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 4 April 2024
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Lifesaving › Launching Appliances › Davit
Issued 6 October 2016 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving apopliances shall be in working order and ready for immediate use. PSCO observed an improperly installed remote launching line which resulted in damage to the starboard side life/rescue boat davit sytem. SOLAS 74 (14 cons.) Ch. III Reg. 20.2, 17 ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2016
Resolved 7 October 2016
Resolution: Received class report attesting to repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 6 October 2016 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed a significant amount of fuel oil surrounding the cylinders on the main diesel engine. SOLAS (04 cons.) Ch. II-2 Reg. 4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2016
Resolved 7 October 2016
Resolution: Received class report attesting to repairs.
Electrical › Electric Supply System (service) › Cable
Issued 6 October 2016 Resolved
Electrical installations shall be such that the safety of the crew and ship from electrical hazards will be ensured. PSCO observed the flame-eye safety device removed from the incinerator. Additionally, exposed wiring on the safety device was observed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2016
Resolved 7 October 2016
Resolution: Received class report attesting to repairs.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 16 February 2011 Resolved
Ships shall carry at least two firefighters outfits. Vessel firefighter outfits are worn and deteriorated. SOLAS09(Cons.) II-2/10.2.1 17a
Action required: 705 - Other - as specified
Resolved 16 February 2011
Resolution: Received Classification society surveyor’s report. Report states one new firefighting outfit has been purchased and the best top and bottom from the old sets were paired to make a temporary use suit. New suit is to be purchased NLT 10 MAR 2011.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 November 2008 Resolved
Vessel unable to provide hydrostatic report or record for test of the bunkering lines.
Action required: 703 - Prior to bunkering operations
Due 8 November 2008
Resolved 8 November 2008
Resolution: Vessel provided documentation of completed hydro test for bunker and lube oil piping.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 March 2008 Resolved
VESSEL DOES NOT HAVE AN APPROVED NON-TANK VESSEL RESPONSE PLAN. COMPANY TO SUBMIT PLAN FOR REVIEW TO USCG.
Action required: 705 - Other - as specified
Resolved 2 May 2008
Resolution: WENT ONBOARD AND VERIFIED THE APPROVED NON-TANK VESSEL RESPONSE PLAN.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.