MAURY USCG vessel records Sign in
← All vessels

MTM POTOMAC

MTM POTOMAC is a 2004 tank ship. The Coast Guard has recorded 29 inspections since 2005, most recently in July 2022, along with 13 deficiencies and 4 operational controls.

Records from 2005 to 2022. Most recent: inspection, 12 July 2022.

Built
2004
Last inspected
12 July 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9281920 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V6611
742376
Flag
SINGAPORE
—
Maury page id
psix-742376

Inspections, by type

…with no type recorded5
Years with a record 12 calendar years (2005–2022)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it61670 - Displacement, Metric Ton
49999 - Dead Weight, Metric Ton
30131 - Convention (Subpart B), Gross Ton
13701 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

12 July 2022 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7504492
10 July 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7499498
19 October 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7074584
9 October 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7074582
22 February 2020 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6917735
17 February 2020 Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6910314
3 May 2019 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6675831
30 April 2019 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6673244
6 December 2017 COE-Offshore · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6319281
4 December 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6317773
24 February 2017 Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6091734
2 January 2017 COC-CHEM & TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6064594
15 September 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6001260
6 January 2016 COE-Dockside
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5792142
15 November 2015 Ballast Water Examination · ISPS III Exam · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5762031
8 November 2015 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5759485
27 March 2014 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4808023
13 October 2010 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3869148
1 October 2010 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3856263
28 March 2010 COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3704130
14 December 2009 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3650192
28 April 2009 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3462840
12 July 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2992273
5 June 2007 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2952655
18 April 2006 COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2628025
14 February 2006 MARPOL Annex I Examination · Random ISPS/MTSA/PSC · MARPOL Annex II Examination · MARPOL Annex V Examination · Deficiency Check · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2584708
12 July 2005 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2424287
7 April 2005 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2327938
6 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2329657

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 July 2022 Resolved
07114 - The machinery, boilers, and other pressure vessels, associate piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Emergencu fuel stop of valve #1 HFO tank(p) did not close as intended. 74SOLAS(20) II-I/26.1 15AC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2022
Resolved 12 July 2022
Resolution: The vessel provided documentation attesting to the rectification outstanding. Class (DNV) provided report attesting to the completion of repairs and proper operation of the emergency fuel stop valve for #1 HFO tank(p).
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 May 2019 Resolved
Machinery spaces in addition to the fixed-fire extinguishing system must have a fixed water-based extinguishing system with automatic and manual release capabilities. The purifier rooms secondary hyper-mist system does not have automatic release capabilities. SOLAS 74(09) II-2/10.5.6.2
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2019
Resolved 4 May 2019
Resolution: Received survey statement from DNV GL. Repairs were made to their satisfaction. (see in documents). Shore based service company, Consilium Marine USA carried out a software upgrade and tested the system and found it working properly without alarms
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 May 2019 Resolved
A cargo tank must have a thermometer with a temperature reading. The number 1 port cargo tank temperature sensor is misreading the Cargo Control Room 46 CFR 153.440(a)(3)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 February 2020
Resolution: Class report was submitted attesting to satisfactory repair of cargo tank thermometer.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2019 Resolved
Vessel must submit a ballast report no later than 06 hours after arrival. Vessel failed to submit a ballast report. 33 CFR 157.2060
Action required: 10 - Deficiency Rectified
Resolved 3 May 2019
Resolution: Deficiency was rectified on the spot.
Documentation › Certificates/Documents › IOPP Certificate
Issued 27 March 2014 Resolved
0150-IOPP- Vessel's supplement to the IOPP states the vessel is equipped with a MEPC 107 oil content meter. However, vessel has a MEPC 60 oil content meter installed. -MARPOL 73/ 78 Annex I/7
Action required: 705 - Other - as specified
Due 10 April 2014
Resolved 1 April 2014
Resolution: Received, reviewed and accepted class report stating IOPP was changed
Deck/Cargo › Ballast › Piping
Issued 27 March 2014 Resolved
0940-Ballast - PSCO observed the fixed gas detection system was turned off. C/O stated, even when in ballast condition he only turns on once a day to prevent overheating inside the cabinet. - SOLAS 74 am II-2/4.5.7
Action required: 705 - Other - as specified
Due 10 April 2014
Resolved 1 April 2014
Resolution: Received, reviewed and accepted class report from DNV stating the system is operating as designed.
Deck/Cargo › Ballast › Piping
Issued 27 March 2014 Resolved
0940-Ballast- Ship's crew could not demonstrate calibration of the fixed gas detection system utilizing the installed calibration gas and associated piping system. - SOLAS 74 am II-2/4.5
Action required: 705 - Other - as specified
Due 27 March 2014
Resolved 1 April 2014
Resolution: Received, reviewed and accepted class report from DNV stating new calibration gas was provided and associated piping was cleaned. The system is now operating as designed.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 1 October 2010 Resolved
While testing the high level/overfill alarm the PSCO noticed that the audible alarm in the cargo control room was inoperable. Vessel shall repair this alarm to the satisfaction of class prior to the next loading operation or with-in seven days, whichever occurs first. Class to attest to the proper repair of the alarm. 49 CFR39.20-7 40(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2010
Resolved 13 October 2010
Resolution: recieved Class Survey report
Documentation › Logs/Records › Garbage Recordkeeping
Issued 5 June 2007 Resolved
The garbage plan states that the blue containers are for food waste. However, there are a few cans that contain food but are not the right color. In addition fresh food waste was found in the food grinder in the galley. Believe the cook was disposing of food waste while in port. All containers must be properly marked according to the plan and the grinder secured while in port.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 July 2007
Resolution: Received report from the Master along with photos showing that all the cans are now color coded. The operation of the food grinder while in port has been addressed.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 5 June 2007 Resolved
None of the electrical matting has any type of documentation indicating what safety voltage it is rated for. The company needs to provide documentation for the matting or replace it for the safety of the crew.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 July 2007
Resolution: Received a report from the Master along with a receipt for approved electrical matting which meets the requirements for SOLAS.
Lifesaving › Immersion Suits › General
Issued 5 June 2007 Resolved
During the lifeboat drill the crew put on their immersion suits. More than half of them went pass the 2, minute time required by LSA Code 2.3.1.1. The suits had buoyancy chambers, when crewmembers did get them on they asked the USCG inspector if they had to put on their lifejackets over the suits. One member could not put his on due to his size. Training plus one XXXL suit needs to be provided.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 July 2007
Resolution: Received a report form the Master along with a crew listing of the correct sizes for the immersion suits. In addition training has been carried out in order to meet the 2, minute requirement.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 14 February 2006 Resolved
IGS deck seal discharge piping has a small fracture and is slowly leaking water. Repair the same, prior to conducting cargo operations at next U.S. port.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 February 2006
Resolution: Recieved faxed confirmation (DNV report dated 14FEB06) that def was corrected.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 February 2006 Resolved
OWS ships dwgs is showing a check valve (#BG50), and OWS units instruction manual does not show this valve on its schematics or mention procedures for its use. This valve connects the OWS overboard line and return line (bilge holding tank), and is additionally located after three way valve.. OWS inst manual must be ammended to include location/function of valve. To satisfaction of class society.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 March 2006

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.