Records from 2016 to 2020. Most recent: inspection, 9 March 2020.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLIAM E MUNSON CO INC · BURLINGTON, WA, UNITED STATES · built 2005
Hull materialAluminum
PropulsionJet Drive
Hull shapeBox
Hull configurationMonohull
Hailing portVALDEZ, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 5 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Simplified, Gross Ton
30 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
7 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 7
9 March 2020
Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6923352
18 September 2018
COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6543295
24 April 2018
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6398868
2 March 2018
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6364801
19 July 2017
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6306763
21 June 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6188554
15 July 2016
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5939271
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 March 2020
Resolved
Vessel shall not operate in a commercial capacity until a drydock exam and Certificate of Inspection exam is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2020
Resolution: COI has been deactivated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 September 2018
No resolution recorded
Vessel's lifering retro reflective material was faded.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 September 2018
No resolution recorded
Vessel's lifejacket batteries were alkaline and had no date for installation.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 September 2018
No resolution recorded
Vessel's first aid kit had expired medication.
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 September 2018
No resolution recorded
Vessel only way of retrieving a man overboard was through the utilization of the bow door. Vessel must have another means of retrieving a MOB.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 September 2018
No resolution recorded
Vessel was utilizng a hose as an additional fuel tank vent. Vessel must remove hose.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drills/Instruction › Fire
Issued 2 March 2018
Resolved
Conduct fire and man overboard drills in the presence of a USCG Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2018
Resolved 24 April 2018
Resolution: Witnessed satisfactory man overboard and fire drills
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 2 March 2018
Resolved
Complete a satisfactory Drug and Alcohol program audit with a USCG Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2018
Resolved 24 April 2018
Resolution: Verified enrollment in a drug consortium and negative pre-employment drug tests for all crew.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 July 2016
Resolved
Install fixed fire extinguishing system manual pull (46CFR181.420(a)(2)).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Rcvd email dtd 14Aug2016 w/ pics indicating installation of manual pull.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 July 2016
Resolved
Install means to automatically shut down generator when fixed fire extinguishing system actuates (46CFR181.420(a)(3)).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 5 October 2016
Resolution: Rcvd video fm [name withheld] showing proper automatic shutdown & restart of generator in overide mode.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 15 July 2016
Resolved
Provide AII portable fire extinguisher & conspicously mark location in accomodation space (46CFR181.520).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Rcvd email dtd 14Aug2016 w/ pics indicating installation of AII & marked fire extinguisher.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 15 July 2016
Resolved
Reposition BII portable fire extinguisher in vicinity of machinery space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Rcvd email dtd 14Aug2016 w/ pics indicating repositioning of BII fire extinguisher.
Lifesaving › Lifebuoys › Approval
Issued 15 July 2016
Resolved
Install retroreflective material to both ring life buoys.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Rcvd email dtd 14Aug2016 w/ pics indicating installation of retro material.