09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 August 2025
Resolved
Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support, except that on vessels of not more than 19.8 meters (65 feet). MI observed excessive use of zipties for supporting multiple cable transit in 1) engine room, 2) Fuel tank void, 3) pilot house; replace with appropriate metallic support to MI satisfaction.
46 CFR 183.340
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 October 2025
Resolution: MI observed proper supports being installed in identified spacees.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 August 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Engine room receptacle mounted on ceiling had missing cover.
46 CFR 183.200(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 October 2025
Resolution: Receptacle had proper cover installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 August 2025
Resolved
Each lighting fixture and lampholder must be fixed. MI observed light not permanently fixed hanging in vicinity of fuel tank bulkhead in engine room. Permanently mount or remove wiring with no exposed dead-end wires.
46 CFR 183.410(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 October 2025
Resolution: Lighting fixture was removed and wires properly capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2025
Resolved
Exhaust gas must not leak from the piping or any connections. MI observed minor exhaust leak coming from top vicinity of port engine.
46 CFR 182.430
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 December 2025
Resolution: Vessel mechanic identied bad fuel injector, replaced parts, and fixed exhaust leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 August 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump....provided that: the pump is permanently mounted. Vessel's 04 bilge pumps were observed not permanently mounted. Mount them so they are permanently fixed to the bottom of each space.
46 CFR 182.520(e)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 October 2025
Resolution: Bilge pumps were permanently mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 August 2025
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. MI observed non-vapor tight penetrations in the FWD bulkhead of the engine room. Make vapor tight to MI satisfaction.
46 CFR 177.405(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 October 2025
Resolution: Identified areas were made vapor tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 August 2025
Resolved
Starting motors, generators, and any spark producing device must be mounted as high above the bilges as practicable. MI observed loose generator mounts when conducting operational test. Operator tightened in MI presence.
46 CFR 182.410(a)
Action required: 10 - Deficiency Rectified
Resolved 24 October 2025
Resolution: MI observed generator mounts being tightened.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 August 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: be installed in accordance with the manufacturers instructions. While attending vessel, MI observed fireboy interlock fail; upon electrically simulating activation, the engines properly secured but were able to be started without the override function being enabled.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2025
Resolution: Video recieved of interlock functioning properly.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2020
Resolved
no repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The procedures to be followed in notifying the Coast Guard about vessel repairs vary according to the type of vessel and service in which engaged. Vessel owner/operator notified CG that the vessel suffered damage due to Hurricane Sally in accordance with applicable regulatory cite. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a).
Action required: 705 - Other - as specified
Resolved 20 August 2024
Resolution: In reference to MISLE activity id: 7589093 USCG Inspectors stated vessel satisfactorily rectified work list items generated, cropping out unauthorized repairs and executing repairs under CG oversight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 May 2020
Resolved
Scuttle to engine room had damaged/worn gasket that needs to be replaced in order to maintain watertight integrity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 8 June 2020
Resolution: Vessel Owner, secured gasket, provided pictures to satisfaction of MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 May 2020
Resolved
Collision bulk head penetrations were not sealed for watertight fit. Secure to maintain watertight integrity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 8 June 2020
Resolution: Penetrations in collision bulkhead were made watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 May 2020
Resolved
Vessel generator had exposed wiring above rotating machinery. Electrical equipment must be installed to protect passengers, crew, and others persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2020
Resolved 8 June 2020
Resolution: Vessel secured loose wiring above gen and main diesel engine.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 20 May 2019
Resolved
Stability letter was not posted for operator use. Post stability letter at operating station for use by operator.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 3 June 2019
Resolution: Owner sent photograph of stability letter properly posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 May 2019
Resolved
Vessel did not have portable hand bilge pump. Provide 5GPM hand pump with suitable hose for use on vessel
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2019
Resolved 20 May 2019
Resolution: Vessel representative provided suitable hand bilge pump
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 8 August 2017
Resolved
Post EAP hotline number.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 20 September 2017
Resolution: Inspected.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 8 August 2017
Resolved
Replace flame screen on both fuel tank vents.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 20 September 2017
Resolution: Inspected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 August 2017
Resolved
Wires need metal supports spaced not more than 2’ apart.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 20 September 2017
Resolution: Inspected.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 8 August 2017
Resolved
Life float water light tether needs to be at least 18’ in length.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 20 September 2017
Resolution: Inspected.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 August 2017
Resolved
Install GPS to VHF-DSC and input MMSI.
Action required: 705 - Other - as specified
Due 8 October 2017
Resolved 25 October 2017
Resolution: VHF is installed with DSC and MMSI number.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 August 2017
Resolved
Forward fuel tank fill pipe needs to be electrically bonded at flexible sections.
Action required: 705 - Other - as specified
Due 8 October 2017
Resolved 25 October 2017
Resolution: Filling tube metal connections is bonded.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 June 2016
Resolved
Fire extinguisher did not have required documentation. Provide maintenance logs for all fire extinguishers
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 28 June 2016
Resolution: Maintenance log and proper documentation was provided for all fire extinguishers.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 2 June 2016
Resolved
Provide proof of enrollment and roster for all crewmembers in DAPI program
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 28 June 2016
Resolution: Proof of enrollment for all crewmembers in DAPI was provided.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 2 June 2016
Resolved
Provide proof of supervisory training for second master on EAP training
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 28 June 2016
Resolution: Proof of supervisory training was provided and EAP training.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 2 June 2016
Resolved
Provide suitable storm rails at ladder on second deck
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 28 June 2016
Resolution: Suitable storm rails were provided at ladder on second deck.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 2 June 2016
Resolved
Fire boy in engine room needs a better fixed base
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 28 June 2016
Resolution: Provided better fixed base for fire boy in engine room.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 May 2016
Resolved
Fire suppression system needs to be serviced.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2016
Resolved 2 June 2016
Resolution: Replaced system with new and serviced fire suppression system
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 May 2016
Resolved
Contents inside first-aid kit expired replace with updated contents.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 2 June 2016
Resolution: Replaced with updated first-aid kit
Engineering › Fuel Oil Service System › Piping
Issued 20 May 2016
Resolved
Fuel leaking from fuel manifold in ENG room
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 2 June 2016
Resolution: Properly secured fuel leak
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 20 May 2016
Resolved
Rules of the road Nav rules is outdated replace with updated copy.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 2 June 2016
Resolution: Updated Rules of the road Nav rules
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 May 2016
Resolved
Engines were not ran and drills will need to be performed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 2 June 2016
Resolution: Engine was ran and drills were conducted
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 August 2014
Resolved
Repair PORT side navigation light
Condition: Improper/Lack of Maintenance
Due 6 September 2014
Resolved 10 September 2014
Lifesaving › Buoyant Apparatus › Pendant
Issued 6 August 2014
Resolved
Correctly store pendants for the life float. Zipties are not authorized.
Condition: Improper/Lack of Maintenance
Due 6 September 2014
Resolved 10 September 2014
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 30 May 2012
Resolved
Provide alcohol testing kit.
Due 29 June 2012
Resolved 1 March 2013
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 30 May 2012
Resolved
Remove oily rags from port engine guard and mount properly.
Due 29 June 2012
Resolved 1 March 2013
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 May 2012
Resolved
Stencil vessel name on ring buoy.
Due 29 June 2012
Resolved 1 March 2013
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2012
Resolved
Provide updated navigation chart.
Due 29 June 2012
Resolved 1 March 2013
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 May 2012
Resolved
Replace starboard nav light.
Due 29 June 2012
Resolved 1 March 2013
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 May 2012
Resolved
Remove spare unused items in engineroom.
Due 29 June 2012
Resolved 1 March 2013
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 March 2010
Resolved
Provide log for training for the crew IAW 46 CFR 185.420.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 9 April 2010
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 11 March 2010
Resolved
Provide marking for upper deck, to prohibit entry to passengers.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 9 April 2010
Navigation › Piloting/Steering › Marine Charts
Issued 11 March 2010
Resolved
Provide current tidal tables and updated charts IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 9 April 2010
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 11 March 2010
Resolved
Provide labels for engine room vents stored in locker.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 9 April 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 March 2010
Resolved
Provide testing procedures for fixed fire protection IAW 46 CFR 176.810.
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 9 April 2010
Construction/Loadline › Penetrations › Valve Flange
Issued 7 May 2009
Resolved
Provide and install metal valves in way of bilge overboard in both mid-body compartments.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Stainless steel valves were installed in bilge overboard.
Construction/Loadline › Penetrations › Pipe Flange
Issued 7 May 2009
Resolved
Provide and install hose clamps on A/C cooling water overboard piping.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Hose clamps were installed.
Construction/Loadline › Structures › Superstructure
Issued 7 May 2009
Resolved
Make proper repairs to wooden caps on rails on the port side.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Wooden caps were repaired.
Construction/Loadline › Penetrations › Valve Flange
Issued 7 May 2009
Resolved
Make all sea cocks available for inspection.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Remaining four seavalves were inspected.
Construction/Loadline › Hull › Bottom Plating
Issued 7 May 2009
Resolved
Provide and install propellers, shafts, and rudders.
Action required: 705 - Other - as specified
Resolved 7 May 2009
Resolution: Propellers, shafts, and rudders were installed.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 23 October 2008
Resolved
Replace expired batteries in waterlights for both ring buoy and life float as per 46 CFR 185.726.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: All expired batteries were replaced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 October 2008
Resolved
Provide current training logbook as per 46 CFR 185.420.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Current training logbook is on board.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 23 October 2008
Resolved
Provide proof of steering gear, controls, and communication system tests a required by 46 CFR 185.320.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Operator is logging tests required by 46 CFR 185.320.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 23 October 2008
Resolved
Provide current copies of US Coast Pilot [name withheld] List, Tidal Current Tables, and Rules of the Road as per 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Copies of all required navigation publications are on board.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 23 October 2008
Resolved
Provide proof of monthly testing of EPIRB as per 46 CFR 185.728.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Current EPIRB testing log is on board.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 October 2008
Resolved
Provide rail courses or equivilant for rail on bow as per 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Passengers are not allowed access to area on bow; therefore, this requirement is cleared.
Lifesaving › Lifefloat › Paddle
Issued 23 October 2008
Resolved
Replace deteriorated paddle on lifefloat as per 46 CFR 180.175.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Paddle was replaced on lifefloat.
Engineering › Steering Gear System › Linkage
Issued 23 October 2008
Resolved
Install double nut, Nylok nut, or cotter pin on port side streering arm bolt as per 46 CFR 182.610.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Nylok nut was installed on the steering arm bolt.
Engineering › Bilge Water Management System › Valve
Issued 23 October 2008
Resolved
Replace plastic valve on through-hull fitting on port side of lazarette as per 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Stainless steel valve was installed on through-hull fitting in lazarette.
Engineering › Sea-water System (primary cooling) › Valve
Issued 23 October 2008
Resolved
Replace plastic through-hull fittings and valves in two locations on starboard side in engine room as per 46 CFR 182.720.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Stainless steel valves were installed at thru-hull fittings in engine room.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 23 October 2008
Resolved
Properly mount sewage pump as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Sewage pump was properly mounted.
Engineering › Fuel Oil Service System › Filter
Issued 23 October 2008
Resolved
Prove fuel filter for ship's service generator is marine grade as per 46 CFR 182.455(b)(6).
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Flame impingement bowl was installed at fuel filter.
Engineering › Fuel Oil Service System › Filter
Issued 23 October 2008
Resolved
Remove diesel fuel from flame epingement bowl on starboard main diesel engine fule filter as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Diesel fuel was removed from flame impingement bowl.
Electrical › Electric Generation Source (service) › Panelboard
Issued 23 October 2008
Resolved
Properly mount gauge panel on port main engine as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Gauge panel was mounted with bolts.
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 October 2008
Resolved
Provide battery cutoff switch for ship's service generator battery bank as per 46 CFR 183.380(i).
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Battery cutoff switch was installed for battery bank.
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 23 October 2008
Resolved
Provide proper length bolts for shaft coupling on port side as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 23 November 2008
Resolved 7 May 2009
Resolution: Proper-length bolts were installed at port shaft coupling.
Lifesaving › Rescue Boat › Construction
Issued 30 November 2007
Resolved
Provide a means to recover an unconscious person from the water, in way of a metal rescue platform in lieu of a rescue boat as per 46 CFR 180.210.
Action required: 705 - Other - as specified
Due 30 December 2007
Resolved 17 January 2008
Resolution: OCMI determined vessel did not have to provide a metal rescue platform and CG-835 was rewritten for vessel to prove it can assist a helpless person in the water as per 46 CFR 180.210.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 19 October 2007
Resolved
Properly label the ditribution panel on the 12 volt system, in waof the bilge pumps as per 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Properly labeled the distribution panel on the 12 volt system, in way of the bilge pumps as per 46 CFR 183.340.
Fire Fighting › Ventilation Systems › Ducts
Issued 19 October 2007
Resolved
Prove proper operation of the engine room ventillation shutdown as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Proved proper operation of the engine room ventillation shutdown as per 46 CFR 176.800.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 19 October 2007
Resolved
Provide a means to recover an unconcious person fromthe water as per 46 CFR 180.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 30 November 2007
Resolution: Provided a means of a wooden platform to recover an unconcious person from the water. The platform was accepted as a temporary platform until a metal platform is constructed.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 17 October 2007
Resolved
Provide a Marine Radio Operators Permit as per 47 CFR 80.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Provided a Marine Radio Operators Permit as per 47 CFR 80.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 October 2007
Resolved
Prove that the fixed fire fighting system has been serviced within the past year as per 46 CFR 176.810.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 19 October 2007
Resolution: Proved that the fixed fire fighting system was serviced within the past year as per 46 CFR 176.810.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 October 2007
Resolved
Provide a Coast Guard Light List and Tidal Current Tables as per 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Provided a Coast Guard Light List and Tidal Current Tables as per 46 CFR 184.420.
Lifesaving › Visual Distress Signals (General) › Marking
Issued 17 October 2007
Resolved
Properly mark the watertight container for the visual distress signals as per 46 CFR 185.614.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Properly marked the watertight container for the visual distress signals as per 46 CFR 185.614.
Construction/Loadline › Structures › Superstructure
Issued 17 October 2007
Resolved
Make repairs to the hole inside the console on the starboard side of the Pilot House as per 46 CFR 176.802.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 19 October 2007
Resolution: Made repairs to the hole inside the console on the starboard side of the Pilot House as per 46 CFR 176.802.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 October 2007
Resolved
Properly clean the vessel as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Properly cleaned the vessel as per 46 CFR 176.800.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 October 2007
Resolved
Provide a Coast Guard approved waterlight for the lifefloat as per 46 CFR 180.200.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2007
Resolved 19 October 2007
Resolution: Provided a Coast Guard approved waterlight for the lifefloat as per 46 CFR 180.200.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 17 October 2007
Resolved
Prove proper operation of the pre-engineered fire fighting system, in way of the alarm and discharge light as per 46 CFR 181.400.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2007
Resolved 19 October 2007
Resolution: Proved proper operation of the pre-engineered fire fighting system, in way of the alarm and discharge light as per 46 CFR 181.400.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 17 October 2007
Resolved
Secure the oil leaks on the starboard main diesel engine as per 46 CFR 178.800.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Secured the oil leaks on the starboard main diesel engine as per 46 CFR 176.800.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 October 2007
Resolved
Tighten the bolts on the machinery guard for the starboard engine as per 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Tightened the bolts on the machinery guard for the starboard engine as per 46 CFR 177.960.
Engineering › Fuel Oil Service System › Hose
Issued 17 October 2007
Resolved
Shorten and properly mount the generator's return fuel hose as per 46 CFR 182.710.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Shortened and properly mounted the generator''s return fuel hose as per 46 CFR 182.710.
Engineering › Bilge Water Management System › Pump
Issued 17 October 2007
Resolved
Prove proper operation of all bilge pumps as per 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Proved proper operation of all bilge pumps as per 46 CFR 185.520.
Electrical › Electric Supply System (service) › Battery Charger
Issued 17 October 2007
Resolved
Provide an ammeter for the battery charger as per 46 CFR 183.310.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Provided an ammeter for the battery charger as per 46 CFR 193.310.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 October 2007
Resolved
Properly mount the wires in the lazarette as per 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Properly mounted the wires in the lazarette as per 46 CFR 183.340.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 October 2007
Resolved
Remove the dead end wire in the aft portion of the Pilot House as per 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 21 November 2007
Resolution: Removed the dead end wire in the aft portion of the Pilot House as per 46 CFR 183.340.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 October 2007
Resolved
Properly clean the bilges to be free from oil and trash as per 46 CFR 176.800.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 November 2007
Resolved 19 October 2007
Resolution: Properly cleaned the bilges to be free from oil and trash as per 46 CFR 176.800.
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 October 2007
Resolved
Conduct man overboard, fire fighting and abandon ship drills in the presence of a Coast Guard Marine Inspector as per 46 CFR 185.702
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 19 October 2007
Resolution: Conducted man overboard, fire fighting and abandon ship drills in the presence of a Coast Guard Marine Inspector as per 46 CFR 185.702
Construction/Loadline › Penetrations › Weld
Issued 18 April 2007
Resolved
Grind and weld the marked area around the starboard through hull fitting in accordance with NVIC 11-80
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Resolution: Made repairs to the marked area
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 18 April 2007
Resolved
Replace the port cutlass bearing as required by 46 CFR 176.630
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Resolution: Replaced the port cutlass bearing
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 18 April 2007
Resolved
Install propellers and make ready for inspection as required by 46 CFR 176.610
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Resolution: Installed the propellers and made ready for inspection
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2006
Resolved
Properly secure the electrical cable and the dead end cable in the mid body of the vessel in accordance with 46 CFR 183.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 20 December 2006
Resolution: Properly secured electrical cable and dead end cable in mid body compartment.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 25 October 2006
Resolved
Properly secure the cooling water pump for the A/C unit in the mid body compartment.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 20 December 2006
Resolution: Properly secured the cooling water pump for the A/C unit in mid body compartment.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 October 2006
Resolved
Properly secure the bilge high level alarm in the mid body compartment.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 20 December 2006
Resolution: Properly secured the bilge high level alarm in the mid body compartment.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 October 2006
Resolved
Make the bulkhead penetration for the steering hydraulic lines in the forward bulkhead of the lazarette, watertight.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 7 December 2006
Resolution: The bulkhead penetration for the steering hydraulic lines in the forward bulkhead of the lazarette were made watertight.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 25 October 2006
Resolved
Properly secure the A/C unit in the forward compartment.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 7 December 2006
Resolution: A/C unit was properly secured in the forwarf compartment.
Engineering › Lubricating Oil Service System › Drain Tank
Issued 25 October 2006
Resolved
Provide and install plugs in both lube oil drains on both main diesel engines.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 7 December 2006
Resolution: Plugs were installed in both lube oil drains on the main diesel engines.
Engineering › Fuel Oil Service System › Valve, Control
Issued 25 October 2006
Resolved
Provide and install a second means of securing the fuel to the ship's service generator.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 7 December 2006
Resolution: A second valve was installed at the generator as a second means of securing fuel to the service generator.
Engineering › Bilge Water Management System › Not Operational
Issued 25 October 2006
Resolved
Remove all trash and oil from the engine room bilge.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 20 December 2006
Resolution: Removed all trash and oil from the engine room bilge.
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 October 2006
Resolved
Properly secure battery box lids in the engine room.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 7 December 2006
Resolution: Battery box lids in the engine room were properly secured.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 October 2006
Resolved
Provide and install guards over rotating equipment on both main engines.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 20 December 2006
Resolution: Provided and installed guards over rotating equipment on both main engines.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 October 2006
Resolved
Provide current charts, Light List and Tidal Currents for the area of operation.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 7 December 2006
Resolution: Current charts, Light List, and Tidal current table were provided.
Lifesaving › Lifefloat › Markings
Issued 25 October 2006
Resolved
Properly mark the lifefloat with the number of passengers.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 7 December 2006
Resolution: Lifefloat was properly marked with the number of passengers.
Electrical › Electric Generation Source (service) › Panelboard
Issued 25 October 2006
Resolved
Provide and install a frequency meter for the ship service generator.
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 7 December 2006
Resolution: A frequency meter was installed for the ship service generator at the operating station.
Personnel › Training › Personal Safety/Social Responsibilities
Issued 22 July 2005
Resolved
Secure pilot's chair in pilot house IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 5 January 2006
Resolution: Pilot''s chair in pilot house was secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 July 2005
Resolved
Enclose loose wiring in pilot house IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 5 January 2006
Resolution: Wiring enclosed in pilot house.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 July 2005
Resolved
Ensure all breaker installations meet those on approved plans IAW 46 CFR 183.380.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 5 January 2006
Resolution: All breaker installations meet the approved plans IAW 46 CFR 183.380.
Stability › Weathertight Integrity › General
Issued 22 July 2005
Resolved
Ensure aft door in cabin is weathertight IAW 46 CFR 175.400.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 5 January 2006
Resolution: Aft door in cabin was proven to be weathertight.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 July 2005
Resolved
Enclose all dead end wires in a watertight enclosure IAW 46 CFR 183.220.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 5 January 2006
Resolution: All dead end wires in the watertight enclosure were enclosed.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 22 July 2005
Resolved
Perminantly secure MSD tank IAW 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 5 January 2006
Resolution: MSD tank was perminantly secure.