Records from 2016 to 2025. Most recent: inspection, 16 April 2025.
Inspection history · 24
16 April 2025
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8111918
6 August 2024
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7971568
21 June 2024
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7939497
9 April 2024
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7892504
17 January 2024
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7848403
28 June 2023
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7725933
11 October 2022
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7571990
8 March 2022
Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7407958
23 December 2021
PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7371780
24 April 2021
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7180508
27 May 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6961541
23 May 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6960884
27 April 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6944681
22 March 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6930084
21 March 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6929920
28 February 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6917815
5 July 2019
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6733319
7 December 2018
Ballast Water Examination · NPV Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6593700
15 June 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6444843
18 July 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6213113
25 May 2017
Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6153485
2 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6051259
2 December 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6138883
7 November 2016
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6036475
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 August 2024
Resolved
Detectors shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. PSCO observed flame detector being tested with a handheld lighter. No suitable devices on board.
Cite :74SOLAS(04)II-2/7.2.2 Code 50c
FSS Code 9.2.5.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 27 August 2024
Resolution: Recieved documentation of reciept of flame detector.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 21 June 2024
Resolved
To assist in casualty investigation ships, when engaged on international voyages, subject to the provisions of regulation 1.4, shall be fitted with a voyage data recorder as follows; Ships VDR is defective and not functioning properly. Solas 74(2020 Cons.) Ch. V/20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2024
Resolved 7 August 2024
Resolution: Vessel provided Class report during insepction. Activity #77971568
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 March 2022
Resolved
Each liferaft shall be stowed with a float-free arrangement complying with the requirements of 4.1.6 of the Code. The painter system shall provide a connection between the ship and the liferaft and shall be so arranged as to ensure that the liferaft when released is not dragged under by the sinking ship. PSCO observed frayed painter line on liferaft.
74 SOLAS 20 III/13.4.2
LSA Code 4.1.6.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 9 March 2022
Resolution: Captain provided adequate photographic evidence.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 March 2022
Resolved
The Administraiton shall ensure that radio equipment required by this chapter is maintained to provide the availability of the functional requirements specified in regulation 4 and to meet the recommended performance standards of such equipment. PSCO observed expired battery on EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2022
Resolved 14 March 2022
Resolution: See classification report under documents tab.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 December 2021
Resolved
07126 - Means shall be provided to control the leaks of flammable liquids. PSCOs observed oil leaking from the oil mist detector to an unauthorized container, leaks from the condenser from the compressor, leaks and oily rags on the HFO filters in the purifier room, leaks from the valve on the HFO supply line into a bin, oily rags on the fuel oil pump, oil leaking from the main engine being collected in a container, a container collecting fuel oil under the No. 3 generator, the fuel booster unit leaking fuel into a container, fuel leaking from the filter on the main engine, a tin collecting oil from the gear oil pump, oil soaked lagging on the HFO line, HFO leaking from a filter valve, and the thermal oil line leaking.
74 SOLAS 20 II-2/4.1.1
30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 December 2021
Resolved
15109 - The company should establish procedures to ensure the ship is maintained in accordance with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCOs observed the monthly maintenance report for the engine room for November 2021. The monthly report did not have any remarks for deficiencies 1 & 3. Actions by the crew to place unauthorized plastic containers, hoses, and rags throughout the engine room demonstrated the crew's awareness of deficient conditions in the engine room although they were not properly logged. Additionally, as noted in deficiency 4, the Chief Engineer stated there was tape around a heat detector in the engine room because it was sensitive to light flashes. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions. The Captain of the Port questions the overall implementation of the vessel's SMS under the ISM Code. An external audit conducted by the Flag or RO is required to determine whether the ship is operating in accordance to the ISM Code. Provide a copy of the completed audit report to the USCG prior to departure from port.
74 SOLAS 20 IX/3.1
ISM CODE 10.1
30ac
Condition: Design Flaw
Action required: 30 - Ship detained
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 December 2021
Resolved
13199 - Every shaft essential for the propulsion and safety of the ship or for the safety of persons on board shall be so designed and constructed that they will withstand maximum working stresses. PSCOs observed lube oil leaking from the shaft seal into an unauthorized plastic container.
74 SOLAS 04 II-1/37.3
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 December 2021
Resolved
07123 - The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCOs observed a smoke detector wrapped in electrical tape and a thermal detector wrapped in duct tape in the engine room. Additionally, there were 2 fault alarms on fire control panel in the Engine Control Room.
74 SOLAS 20 II-2/14.21.1.1.2
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 23 December 2021
Resolved
14101 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention. PSCOs observed an unauthorized hose added to the overboard pipeline past the 3-way valve on the oily water separator. A piping diagram showing the addition was not approved.
MARPOL ANNEX I/6.4.2
17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 December 2021
Resolved
11101 - All life-saving appliances prescribed in this subpart shall be fitted with retro-reflective material where it will assist in detection. The retro-reflective tape on the lifeboat was deteriorated.
74 SOLAS 20 III/34
LSA CODE 1.2.2.7
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 December 2021
Resolved
11119 - Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with the recommendations of the Organization. If more than one device is stowed in that location, the number of devices shall also be indicated. The forward stowage location for life jackets and immersion suits did not indicated the number of life-saving appliances in that location.
74 SOLAS 20 III/20.10
17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 December 2021
Resolved
06199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The hatch cover unit pump is leaking hydraulic oil.
74 SOLAS 20 1/11(a)
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 January 2022
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 December 2021
Resolved
06199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The thermal oil heater in the forecastle had a light rigged to it to heat the oil.
74 SOLAS 20 1/11(A)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 January 2022
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 25 May 2017
Resolved
0725- FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. THE AUTOMATIC FIXED WATER MIST SYSTEM WAS NOT READY FOR IMMEDIATE USE: VALVE WAS SECURED DUE TO 01 SOLENOID INOPERABLE. SOLAS 74(2014 cons)II-2/14.2.1.2 40 ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 July 2017
Resolution: Repairs were made and received documentation from class attesting to repairs, see attached docs.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 2 December 2016
Resolved
1410 - Main Propulsion Machinery - The machinery associated piping systems and fittings shall be of a design and construction adequate for the serivce for in which they are intended. PSCOs were made aware of a water leak on the number 5 cylinder on the main diesel engine prior to the vessel arrival. Vessel intends on completing the necessary repairs on board prior to coming in port.04ConsChII-1 26
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2016
Resolved 3 December 2016
Resolution: Ship made repairs to the cylinder head. Class attested to the satisfaction of the repairs.