MAURY USCG vessel records
← All vessels

SAIMAAGRACHT

SAIMAAGRACHT is a 2005 freight ship. The Coast Guard has recorded 24 inspections since 2016, most recently in April 2025, along with 15 deficiencies and 5 operational controls.

Records from 2016 to 2025. Most recent: inspection, 16 April 2025.

Built
2005
Last inspected
16 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 April 2025
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9288069
742802
Flag
NETHERLANDS
Maury page id
psix-742802

Documentation record

Tonnage as PSIX records it18321 - Convention (Subpart B), Gross Ton
7647 - Convention (Subpart B), Net Ton
33648 - Displacement, Ton
23741 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

16 April 2025 PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8111918
6 August 2024 PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7971568
21 June 2024 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7939497
9 April 2024 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7892504
17 January 2024 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7848403
28 June 2023 PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7725933
11 October 2022 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7571990
8 March 2022 Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7407958
23 December 2021 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7371780
24 April 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7180508
27 May 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6961541
23 May 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6960884
27 April 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6944681
22 March 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6930084
21 March 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6929920
28 February 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6917815
5 July 2019 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6733319
7 December 2018 Ballast Water Examination · NPV Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6593700
15 June 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6444843
18 July 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6213113
25 May 2017 Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6153485
2 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6051259
2 December 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6138883
7 November 2016 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6036475

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 August 2024 Resolved
Detectors shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. PSCO observed flame detector being tested with a handheld lighter. No suitable devices on board. Cite :74SOLAS(04)II-2/7.2.2 Code 50c FSS Code 9.2.5.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 27 August 2024
Resolution: Recieved documentation of reciept of flame detector.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 21 June 2024 Resolved
To assist in casualty investigation ships, when engaged on international voyages, subject to the provisions of regulation 1.4, shall be fitted with a voyage data recorder as follows; Ships VDR is defective and not functioning properly. Solas 74(2020 Cons.) Ch. V/20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2024
Resolved 7 August 2024
Resolution: Vessel provided Class report during insepction. Activity #77971568
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 March 2022 Resolved
Each liferaft shall be stowed with a float-free arrangement complying with the requirements of 4.1.6 of the Code. The painter system shall provide a connection between the ship and the liferaft and shall be so arranged as to ensure that the liferaft when released is not dragged under by the sinking ship. PSCO observed frayed painter line on liferaft. 74 SOLAS 20 III/13.4.2 LSA Code 4.1.6.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 9 March 2022
Resolution: Captain provided adequate photographic evidence.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 March 2022 Resolved
The Administraiton shall ensure that radio equipment required by this chapter is maintained to provide the availability of the functional requirements specified in regulation 4 and to meet the recommended performance standards of such equipment. PSCO observed expired battery on EPIRB.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2022
Resolved 14 March 2022
Resolution: See classification report under documents tab.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 December 2021 Resolved
07126 - Means shall be provided to control the leaks of flammable liquids. PSCOs observed oil leaking from the oil mist detector to an unauthorized container, leaks from the condenser from the compressor, leaks and oily rags on the HFO filters in the purifier room, leaks from the valve on the HFO supply line into a bin, oily rags on the fuel oil pump, oil leaking from the main engine being collected in a container, a container collecting fuel oil under the No. 3 generator, the fuel booster unit leaking fuel into a container, fuel leaking from the filter on the main engine, a tin collecting oil from the gear oil pump, oil soaked lagging on the HFO line, HFO leaking from a filter valve, and the thermal oil line leaking. 74 SOLAS 20 II-2/4.1.1 30ac
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 December 2021 Resolved
15109 - The company should establish procedures to ensure the ship is maintained in accordance with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCOs observed the monthly maintenance report for the engine room for November 2021. The monthly report did not have any remarks for deficiencies 1 & 3. Actions by the crew to place unauthorized plastic containers, hoses, and rags throughout the engine room demonstrated the crew's awareness of deficient conditions in the engine room although they were not properly logged. Additionally, as noted in deficiency 4, the Chief Engineer stated there was tape around a heat detector in the engine room because it was sensitive to light flashes. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions. The Captain of the Port questions the overall implementation of the vessel's SMS under the ISM Code. An external audit conducted by the Flag or RO is required to determine whether the ship is operating in accordance to the ISM Code. Provide a copy of the completed audit report to the USCG prior to departure from port. 74 SOLAS 20 IX/3.1 ISM CODE 10.1 30ac
Condition: Design Flaw
Action required: 30 - Ship detained
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 December 2021 Resolved
13199 - Every shaft essential for the propulsion and safety of the ship or for the safety of persons on board shall be so designed and constructed that they will withstand maximum working stresses. PSCOs observed lube oil leaking from the shaft seal into an unauthorized plastic container. 74 SOLAS 04 II-1/37.3 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 December 2021 Resolved
07123 - The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. PSCOs observed a smoke detector wrapped in electrical tape and a thermal detector wrapped in duct tape in the engine room. Additionally, there were 2 fault alarms on fire control panel in the Engine Control Room. 74 SOLAS 20 II-2/14.21.1.1.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 23 December 2021 Resolved
14101 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention. PSCOs observed an unauthorized hose added to the overboard pipeline past the 3-way valve on the oily water separator. A piping diagram showing the addition was not approved. MARPOL ANNEX I/6.4.2 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 23 December 2021 Resolved
11101 - All life-saving appliances prescribed in this subpart shall be fitted with retro-reflective material where it will assist in detection. The retro-reflective tape on the lifeboat was deteriorated. 74 SOLAS 20 III/34 LSA CODE 1.2.2.7 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 23 December 2021 Resolved
11119 - Containers, brackets, racks, and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with the recommendations of the Organization. If more than one device is stowed in that location, the number of devices shall also be indicated. The forward stowage location for life jackets and immersion suits did not indicated the number of life-saving appliances in that location. 74 SOLAS 20 III/20.10 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 December 2021
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 December 2021 Resolved
06199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The hatch cover unit pump is leaking hydraulic oil. 74 SOLAS 20 1/11(a) 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 January 2022
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 December 2021 Resolved
06199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The thermal oil heater in the forecastle had a light rigged to it to heat the oil. 74 SOLAS 20 1/11(A)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 January 2022
Resolved 28 December 2021
Resolution: Received Class Report rectifying this deficiency.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 25 May 2017 Resolved
0725- FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. THE AUTOMATIC FIXED WATER MIST SYSTEM WAS NOT READY FOR IMMEDIATE USE: VALVE WAS SECURED DUE TO 01 SOLENOID INOPERABLE. SOLAS 74(2014 cons)II-2/14.2.1.2 40 ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 July 2017
Resolution: Repairs were made and received documentation from class attesting to repairs, see attached docs.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 2 December 2016 Resolved
1410 - Main Propulsion Machinery - The machinery associated piping systems and fittings shall be of a design and construction adequate for the serivce for in which they are intended. PSCOs were made aware of a water leak on the number 5 cylinder on the main diesel engine prior to the vessel arrival. Vessel intends on completing the necessary repairs on board prior to coming in port.04ConsChII-1 26
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2016
Resolved 3 December 2016
Resolution: Ship made repairs to the cylinder head. Class attested to the satisfaction of the repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.