CHAMPION CONTEST

CHAMPION CONTEST is a 2005 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in March 2026, along with 10 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 2016 to 2026. Most recent: inspection, 22 March 2026.

Built
2005
Last inspected
22 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 March 2026
…with no type recorded3
Operational controls 1 with no removal date recorded
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9272199
743401
Flag
NORWAY
Maury page id
psix-743401

Documentation record

Tonnage as PSIX records it47171 - Dead Weight, Ton
57178 - Displacement, Ton
27472 - Convention (Subpart B), Gross Ton
13857 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

15 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

22 March 2026 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8327549
14 March 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7878860
11 March 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7873064
14 December 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7839178
2 May 2023 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7679276
10 March 2022 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7409830
2 March 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7403914
4 September 2019 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6803512
20 October 2018 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6565097
16 March 2018 Deficiency Check · ISPS II Exam · COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6372901
19 July 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6210297
1 October 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6013747
26 September 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6010113
16 September 2016 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6004526
28 August 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5985115

Deficiency record · 10

05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 2 May 2023 Resolved
05113-At least one search and rescue locating device shall be carried on each side of every cargo ship of 500 gross ton and upwards. Vessel has a condition of class to operate the vessel without a free fall life boat. PSCO observed that the vessel is missing one of two search and rescue locating device. 74 SOLAS (20) III/6.2.2 16ac
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2023
Resolution: PSC NOLA received a class report from Rina Services satisfying the requirement.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 15 March 2022 Resolved
ALL SHIPS OF 300 GROSS TONNAGE AND UPWARDS AND PASSENGER SHIPS IRRESPECTIVE OF SIZE SHALL BE FITTED WITH SPEED AND DISTANCE MEASURING DEVICE, OR OTHER MEANS, TO INDICATE SPEED AND DISTANCE THROUGH THE WATER. VESSEL'S SPEED AND DISTANCE INDICATOR IS NOT OPERATIONAL. VESSEL HAS BEEN GRANTED AN OUTBOUTND LETTER OF DEVIATION FOR COTP ZONE COLUMBIA RIVER TO AFFECT REPAIRS IN VANCOUVER, BC. 74 SOLAS (20) V/19.2.3.4 40 a, c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 May 2023
Resolution: No deficiencies noted for this equipment during the PSC B portion of the exam.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 2 March 2022 Resolved
Materials used in inert gas system shall be suitable for their intended purpose. Valve status indicator on first valve in double block and bleed arrangement(#6550) was missing and had been temporarily repaired with plastic sheeting, zip ties, and a sealant. 74 SOLAS (09) II-2/4.5.5.3.2 FSS code 15.2.2.1.3 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2022
Resolved 3 May 2023
Resolution: No deficiencies noted for this equipment during the PSC B portion of the exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 2 March 2022 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel/oil soaked lagging on M/E cylinder #4. 74 SOLAS (09) II-2/4.1.1 10c
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Old oil soaked lagging was removed and replaced. No leak was present.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 October 2018 Resolved
11132: After any survey of the ship under regulation 7,8,9 or 10 has been completed, no change shall be made in the structural arrangement, machinery, equipment and other items covered by the survey without the sanction of the administration. The water spray system for the fire protected lifeboat has a non-approved soft patch.74 SOLAS(14)I/11.b (17a,c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2018
Resolution: Temporary patch soft patch approved by class. Permanent repairs to be conducted by Nov 22, 2018
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 21 October 2018 Resolved
11129: Before a ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Crew was not able to keep the rescue boat engine running. Engine would start but not maintain RPM. 74SOLAS(14)III/ 20.2 (17a,c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2018
Resolution: As per Class report, Rescue vessel engine is in good order. Repairs completed,
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 October 2018 Resolved
11124: Containers, brackets, racks and other similar stowage locations for life-saving equipment shall be marked with symbols in accordance with the recommendations of the organization indicating the devices stowed in that location for that purpose. The immersion suits and life jackets for the forward life raft are not stored in the correct location. Items should be stored in deck stores, as per plan. 74SOLAS(14)III/20.10 (17 a,c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2018
Resolution: As per class report, lifejackets and immersion suit placed in appropriate location as per vessel safety plan.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 21 July 2017 Resolved
Each tankship with a vapor collection system must be fitted with a pressure in the main vapor collection lines. Vessel's vapor colection system pressure sensors are inoperable. Vessel must make repairs to the satisfaction of class. Must be repaired prior to loading cargo.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 July 2017
Resolved 16 March 2018
Fire Fighting › Fire Hoses › Condition
Issued 26 September 2016 Resolved
0730 - Appliances - Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. During fire hose test, nozzle on starboard bridge wing hose did not permit the passage of water through it, rendering the hose arrangement unable to fight the fire. - 74 SOLAS (14)/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Replaced nozzle with spare.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 26 September 2016 Resolved
1850 - Fire protection cargo area - The venting system shall be provided with devices to prevent the passage of flame into the cargo tanks. Flame screen on starboard slop tank was holed and incapable of preventing the passage of flame. - 74 SOLAS (14) II-2/4.5.3.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 September 2016
Resolution: Replaced with spare onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.