GAMBLER is a 2005 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2016, most recently in February 2026, along with 27 deficiencies and 2 casualty investigations between 2012 and 2017.

Records from 2012 to 2026. Most recent: inspection, 19 February 2026.

Built
2005
Last inspected
19 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 February 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC6021
743927
Flag
UNITED STATES
Maury page id
psix-743927

Documentation record

Registered dimensions (L × B × D)72.0 ft × 25.0 ft × 8.0 ft
Registered tonnagegross 96 / net 77
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPERFORMANCE MARINE INC · ARUNDEL, ME, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPT PLEASANT, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 18 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Simplified, Gross Ton
77 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

19 February 2026 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8312735
8 January 2026 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8292435
20 May 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8139714
10 March 2025 COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8090787
7 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8077256
1 March 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7872677
12 February 2024 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7864558
28 November 2023 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7830806
20 September 2023 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7804013
8 February 2023 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7633850
14 September 2022 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7548888
12 July 2022 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7504840
12 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7448361
12 November 2021 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7349680
17 August 2021 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7289215
28 June 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7263421
13 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7196287
20 April 2021 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7178930
10 February 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7137820
28 April 2020 DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6945288
8 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6830365
28 May 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6696192
7 February 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6619702
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6505905
29 May 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6420245
20 November 2017 Type not recorded
No type recorded · USCGC RELIANCE (WMEC 615) · Activity 6319256
19 October 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6294476
16 May 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6144914
9 March 2017 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6101572
23 May 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5884015

Deficiency record · 27

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 January 2026 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Fireboy system was not properly connected. Vessel must have a technician attend and ensure arrangement is satisfactory. 46 CFR 181.420(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2026
Resolved 17 March 2026
Resolution: MIs attended while servicing technician was present. MI observed vessel test shutdowns and ensured satisfactory installation.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 January 2026 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; Operator could not test engine shutdowns/override on fireboy system. MIs will have to re-attend to witness satisfactory fireboy test prior to carrying passengers. 46 CFR 181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2026
Resolved 17 March 2026
Resolution: MIs witnessed vessel succesfully test shutdowns after repairs were made to the system.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 January 2026 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel must conduct drills prior to carriage of passengers.46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2026
Resolved 17 February 2026
Resolution: Crew succesfully completed drills in the presence of MIs
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 8 January 2026 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel had an expired station license. Vessel is restricted to 1000 feet from shore until new station license is obtained. 46 CFR 184.502
Action required: 705 - Other - as specified
Due 17 February 2026
Resolved 17 February 2026
Resolution: Vessel renewed their FCC station license and MIs verfied it while attending.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 March 2025 Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided in compliance with § 177.970 of this chapter at such locations where persons or equipment might come in contact with an exhaust pipe. Starboard main engine had a 4” gap of lagging from turbo charger into wet exhaust. Add sufficient insulation to prevent injury.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: Owner installed lagging on MDE turbo exhaust.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 March 2025 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit had multiple expired items. Replace first-aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: Owner replaced first aid kit items.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2025 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light. Vessel had 2 missing lights and 3 inoperable lights.
Action required: 10 - Deficiency Rectified
Resolved 10 March 2025
Resolution: Vessel replaced with new lights onsite
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 February 2024 Resolved
Leaking water found on port side generator from water pump and flexible hose into battery bank below. Repair and/or replace parts as needed to stop water leak. Relocate battery bank to protect from wet environment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2024
Resolved 29 February 2024
Resolution: Vessel replaced generator water pump and tightened hose clamp. MI tested generator with no water leaks.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 February 2024 Resolved
Vessel had two VHF radios installed on the same circuit breaker. Provide separate circuit with over current protection at main distribution panel for each radio installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2024
Resolved 29 February 2024
Resolution: Vessel added overcurrent protection to seperate VHF radio installation. MI tested overcurrent protection for each indivudal VHF with sat results.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 May 2022 Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. 09 of the 12 paddles for the life floats were less than 4 feet in length. Replace paddles with the correct length and label paddles with vessels name. 46 CFR 180.175(f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 23 May 2022
Resolution: Received pictures of the new paddles, sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2021 Resolved
Fuel hose on port engine worn from chaffing against steel support mechanism. Repair/replace with new fuel hose of adequate standard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 21 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 May 2021 Resolved
Electronic and paper charts were not updated with recent chart updates. Update both electronic and paper charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 21 July 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 February 2021 Resolved
Discharge ends of fuel tank vent pipes must be fitted with a flame screen and must consist of a single corrosion resistant wire of at least 30x30 mesh. Both port and starboard fuel tank vents did not have flame screens. Install 30x30 wire mesh flame screens to the discharge ends of the fuel tank vent pipes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: O/O installed 30 mesh stainless steel cone type spark arrestor
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2021 Resolved
Metallic sections of a fuel fill pipe must be protected against a static charge. Port fuel fill pipe bonding wire was not connected. Replace bonding wire to Metallic section of port fuel fill pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 12 February 2021
Resolution: Replaced bonding wire.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2020 Resolved
Install fire pump pressure guage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 27 May 2020
Resolution: Received photo from O/O of installed fire pump pressure guage.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 May 2020 Resolved
Repair life float IAW manufactures instruction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 27 May 2020
Resolution: O/O repaired life float IAW manufactures instruction.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 May 2020 Resolved
Replace DOT retro tape with approved SOLAS tape on life floats.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 27 May 2020
Resolution: Received photo of repair from O/O with correct retro on life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2020 Resolved
Missing plug on flame shield of port inboard fuel filter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 27 May 2020
Resolution: Received photo of installed plug that was missing on fuel flame shield.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2020 Resolved
Show proof of random drug testing compliance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 8 May 2020
Resolution: Recieved email from owner with photo copies of random testing compliance.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 October 2019 Resolved
Prior to any persons sleeping the storage room that has bunks the fixed CO2 system bottles and assoc. piping must be relocated. This must be completed to condider this an accomodation space for passengers or crew. Submit plans and calculations for moving the fixed system into another space. 46CFR177.800(d)(1)
Action required: 705 - Other - as specified
Resolved 13 May 2022
Resolution: Vessel submitted plans and removed/installed new pre engineering fire suppression system.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 May 2019 Resolved
Repair identified life float grab line and outer shell IAW manufacturers instruction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2019
Resolved 17 June 2019
Resolution: Replacement of grablines and outer shell have been completed.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 28 May 2019 Resolved
Provide medical readiness for master's license
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 20 June 2019
Resolution: Received email from [name withheld] with new medical certificate.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2019 Resolved
Acquire 01 spanner wrench for fire plug
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: O/O purchased spanner wrench for fire hose.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
Vsl is broadcasting: No static draft information and no dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 8 October 2019
Resolution: Went onboard and verified operation of AIS.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 16 May 2017 Resolved
Vessels FF system that is CO2 and not in compliance the hydro date is more than 12 yrs, must hydro bottles and flex hoses and prove proper operation in the presents of CGMI
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2017
Resolution: Fire company returned to vessel and installed correct equipment
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2017 Resolved
Vessel must get current and up to date marine charts of area of operation.
Due 16 June 2017
Resolved 30 May 2017
Resolution: Vessel has new up to date charts
Fire Fighting › Fire Pumps › Pressure
Issued 16 May 2017 Resolved
Vessel must intall a pressure gage to read at least 60 psi
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 30 May 2017
Resolution: New pressure gage installed on main deck at the fire station discharge

Casualty record · 2

8 December 2012Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · 1 injured · activity 4498814
19 October 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6294476
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.