Records from 2012 to 2026. Most recent: inspection, 19 February 2026.
Inspection history · 30
19 February 2026
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8312735
8 January 2026
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8292435
20 May 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8139714
10 March 2025
COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8090787
7 February 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8077256
1 March 2024
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7872677
12 February 2024
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7864558
28 November 2023
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7830806
20 September 2023
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7804013
8 February 2023
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7633850
14 September 2022
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7548888
12 July 2022
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7504840
12 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7448361
12 November 2021
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7349680
17 August 2021
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7289215
28 June 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7263421
13 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7196287
20 April 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7178930
10 February 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7137820
28 April 2020
DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6945288
8 October 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6830365
28 May 2019
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6696192
7 February 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6619702
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505905
29 May 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6420245
20 November 2017
Type not recorded
No type recorded · USCGC RELIANCE (WMEC 615) · Activity 6319256
19 October 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6294476
16 May 2017
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6144914
9 March 2017
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6101572
23 May 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5884015
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 January 2026
Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Fireboy system was not properly connected. Vessel must have a technician attend and ensure arrangement is satisfactory. 46 CFR 181.420(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2026
Resolved 17 March 2026
Resolution: MIs attended while servicing technician was present. MI observed vessel test shutdowns and ensured satisfactory installation.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 January 2026
Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; Operator could not test engine shutdowns/override on fireboy system. MIs will have to re-attend to witness satisfactory fireboy test prior to carrying passengers. 46 CFR 181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2026
Resolved 17 March 2026
Resolution: MIs witnessed vessel succesfully test shutdowns after repairs were made to the system.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 January 2026
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Vessel must conduct drills prior to carriage of passengers.46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2026
Resolved 17 February 2026
Resolution: Crew succesfully completed drills in the presence of MIs
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 8 January 2026
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel had an expired station license. Vessel is restricted to 1000 feet from shore until new station license is obtained. 46 CFR 184.502
Action required: 705 - Other - as specified
Due 17 February 2026
Resolved 17 February 2026
Resolution: Vessel renewed their FCC station license and MIs verfied it while attending.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 10 March 2025
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided in compliance with § 177.970 of this chapter at such locations where persons or equipment might come in contact with an exhaust pipe. Starboard main engine had a 4” gap of lagging from turbo charger into wet exhaust. Add sufficient insulation to prevent injury.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: Owner installed lagging on MDE turbo exhaust.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 March 2025
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit had multiple expired items. Replace first-aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2025
Resolved 17 March 2025
Resolution: Owner replaced first aid kit items.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 March 2025
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light. Vessel had 2 missing lights and 3 inoperable lights.
Action required: 10 - Deficiency Rectified
Resolved 10 March 2025
Resolution: Vessel replaced with new lights onsite
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 February 2024
Resolved
Leaking water found on port side generator from water pump and flexible hose into battery bank below. Repair and/or replace parts as needed to stop water leak. Relocate battery bank to protect from wet environment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2024
Resolved 29 February 2024
Resolution: Vessel replaced generator water pump and tightened hose clamp. MI tested generator with no water leaks.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 February 2024
Resolved
Vessel had two VHF radios installed on the same circuit breaker. Provide separate circuit with over current protection at main distribution panel for each radio installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2024
Resolved 29 February 2024
Resolution: Vessel added overcurrent protection to seperate VHF radio installation. MI tested overcurrent protection for each indivudal VHF with sat results.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 12 May 2022
Resolved
Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. 09 of the 12 paddles for the life floats were less than 4 feet in length. Replace paddles with the correct length and label paddles with vessels name. 46 CFR 180.175(f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 23 May 2022
Resolution: Received pictures of the new paddles, sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2021
Resolved
Fuel hose on port engine worn from chaffing against steel support mechanism. Repair/replace with new fuel hose of adequate standard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 21 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 May 2021
Resolved
Electronic and paper charts were not updated with recent chart updates. Update both electronic and paper charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 21 July 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 February 2021
Resolved
Discharge ends of fuel tank vent pipes must be fitted with a flame screen and must consist of a single corrosion resistant wire of at least 30x30 mesh. Both port and starboard fuel tank vents did not have flame screens. Install 30x30 wire mesh flame screens to the discharge ends of the fuel tank vent pipes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 25 February 2021
Resolution: O/O installed 30 mesh stainless steel cone type spark arrestor
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2021
Resolved
Metallic sections of a fuel fill pipe must be protected against a static charge. Port fuel fill pipe bonding wire was not connected. Replace bonding wire to Metallic section of port fuel fill pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2021
Resolved 12 February 2021
Resolution: Replaced bonding wire.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2020
Resolved
Install fire pump pressure guage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 27 May 2020
Resolution: Received photo from O/O of installed fire pump pressure guage.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 May 2020
Resolved
Repair life float IAW manufactures instruction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 27 May 2020
Resolution: O/O repaired life float IAW manufactures instruction.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 May 2020
Resolved
Replace DOT retro tape with approved SOLAS tape on life floats.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 27 May 2020
Resolution: Received photo of repair from O/O with correct retro on life float.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2020
Resolved
Missing plug on flame shield of port inboard fuel filter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 27 May 2020
Resolution: Received photo of installed plug that was missing on fuel flame shield.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2020
Resolved
Show proof of random drug testing compliance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2020
Resolved 8 May 2020
Resolution: Recieved email from owner with photo copies of random testing compliance.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 October 2019
Resolved
Prior to any persons sleeping the storage room that has bunks the fixed CO2 system bottles and assoc. piping must be relocated. This must be completed to condider this an accomodation space for passengers or crew. Submit plans and calculations for moving the fixed system into another space. 46CFR177.800(d)(1)
Action required: 705 - Other - as specified
Resolved 13 May 2022
Resolution: Vessel submitted plans and removed/installed new pre engineering fire suppression system.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 May 2019
Resolved
Repair identified life float grab line and outer shell IAW manufacturers instruction.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2019
Resolved 17 June 2019
Resolution: Replacement of grablines and outer shell have been completed.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 28 May 2019
Resolved
Provide medical readiness for master's license
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 20 June 2019
Resolution: Received email from [name withheld] with new medical certificate.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2019
Resolved
Acquire 01 spanner wrench for fire plug
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: O/O purchased spanner wrench for fire hose.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: No static draft information and no dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 8 October 2019
Resolution: Went onboard and verified operation of AIS.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 16 May 2017
Resolved
Vessels FF system that is CO2 and not in compliance the hydro date is more than 12 yrs, must hydro bottles and flex hoses and prove proper operation in the presents of CGMI
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2017
Resolution: Fire company returned to vessel and installed correct equipment
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2017
Resolved
Vessel must get current and up to date marine charts of area of operation.
Due 16 June 2017
Resolved 30 May 2017
Resolution: Vessel has new up to date charts
Fire Fighting › Fire Pumps › Pressure
Issued 16 May 2017
Resolved
Vessel must intall a pressure gage to read at least 60 psi
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 30 May 2017
Resolution: New pressure gage installed on main deck at the fire station discharge