MAURY USCG vessel records Sign in
← All vessels

BSA QUAIL RIDGE EXPLORER

BSA QUAIL RIDGE EXPLORER is a 2005 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 2005, most recently in February 2026, along with 53 deficiencies and 1 operational control.

Records from 2005 to 2026. Most recent: inspection, 6 February 2026.

Built
2005
Last inspected
6 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5704
744100
Flag
UNITED STATES
367045250
Maury page id
psix-744100

Inspections, by type

Years with a record 20 calendar years (2005–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 9.0 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portISLAMORADA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC5704MMSI 367045250 · active · compulsorily equipped · granted 4 March 2025, expires 26 May 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 29

6 February 2026 Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8350941
29 January 2026 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8303630
27 October 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8249064
4 December 2024 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8033230
30 September 2024 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8027319
17 January 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7850268
25 January 2023 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7627017
12 January 2023 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7620435
17 October 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7578615
1 March 2022 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7404777
13 April 2021 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7175229
28 December 2020 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7116911
15 October 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7078510
16 January 2020 DAPI Audit · Internal Structural Exam · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6890551
6 March 2019 Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6637133
29 October 2018 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570528
6 March 2018 Administrative Inspection · DAPI Audit · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6636577
8 February 2017 Annual Inspection · Deficiency Check · Hull Examination · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6208165
10 March 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5830298
16 May 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4858724
17 February 2012 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4273891
2 September 2011 Simplified Stability Test
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4152859
22 March 2010 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3700619
10 April 2009 Hull Examination · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3449892
15 April 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3184471
16 May 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2931948
23 April 2007 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2913691
24 May 2006 Re-Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2655682
2 June 2005 Deficiency Check · Initial Certification
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2373827

Deficiency record · 53

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 February 2026 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 October 2025 Resolved
03 red flares are expired. Replace red flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 27 October 2025 Resolved
Repaint life float with proper paint type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 December 2024 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and 6 hand orange smoke distress signals. Vessel has red flares that expired 4 days ago.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2024
Resolution: New flares have been purchased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 December 2024 Resolved
The words "FIRE BUCKET" must be stenciled in contrasting color on each bucket. Buckets only say FIRE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2024
Resolved 4 December 2024
Resolution: Fire buckets are correctly labeled.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 4 December 2024 Resolved
Each vessel that operates on the high seas, or that operates three miles must have on board a FCC Type accepted Cat 1 406 MHz EPIRB. Need registration paperwork.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2024
Resolved 4 December 2024
Resolution: Reg. paperwork has been located.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 December 2024 Resolved
Alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred. Alcohol swabs are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2024
Resolved 9 December 2024
Resolution: Vessel received alcohol swabs from Constort.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 January 2024 Resolved
Anchor light was not working and lens was heavily "frosted" over. Replace anchor light and test to the satisfaction of attending CG Marine Inspector. Vessel limited to day light hours only until cleared.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2024
Resolved 28 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 April 2021 Resolved
One of the 2 life floats had both paddles dry rotted and plastic breaking off. Need to replace both paddles.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2021
Resolved 13 April 2021
Resolution: Bought 2 new paddels and labeled with vessels name as required. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2021 Resolved
Both main diesel engines (MDE) would not start during the inspection. Must make repairs and test both MDE's and fireboy system prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2021
Resolved 19 April 2021
Resolution: Found several corroded connections, cut and replaced connections. Test SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 January 2020 Resolved
Vessel required to have 53 adult PFDS. Currently only 42 are good. Vessel is restricted to not more than 42 total until new PFD’s are renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
Resolution: All PFDs were renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 January 2020 Resolved
Vessel has electrical problem that causes VHF and GPS to turn off when keyed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
Resolution: Ground wires in the electrical system had chaffed and were causing the systems to ground out. New ground terminal and wires were installed. all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 January 2020 Resolved
Renew reflective tape and place name on both sides of life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
Resolution: Life floats have been repainted and repaired.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 January 2020 Resolved
VHF does not have MMSI or GPS. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
Resolution: MMSI was input, and GPS was wired to the VHF to provide location.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 January 2020 Resolved
Renew reflective tape on life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
Resolution: Life ring was renewed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 January 2020 Resolved
Update navigation publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
Resolution: All publications have been renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 January 2020 Resolved
Renew first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
Resolution: New first aid kit was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 January 2020 Resolved
Stow life float painter correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 May 2020
Resolution: Painter lines were properly attached and stowed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 March 2018 Resolved
Tank room bilge pump is inoperabel. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 6 March 2018
Resolution: New pump was installed and tested prior to completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 March 2018 Resolved
upper life float grab lines are wasted and must be renewed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2018
Resolution: New grablines were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 March 2018 Resolved
Upper life float has excess paint failure and is missing the vessel name. Paint and mark, or renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2018
Resolution: Life float was painted and new stencils applied.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 March 2018 Resolved
Both life float painter lines are not stowed incorrectly and would not float free on their own.
Action required: 10 - Deficiency Rectified
Resolved 6 March 2018
Resolution: Both painters were removed and stowed correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 March 2018 Resolved
Life ring reflective material is wasted and must be renewed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2018
Resolution: New reflective tape was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2018 Resolved
Port engine air intake pipe has been allowed to make contact with the engine room hatch. This has worn a hole into the intake elbow. Repair/renew elbow.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2018
Resolution: Elbow was renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 March 2018 Resolved
Engine room hatch is missing the gasket material and does not seal. repair seals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2018
Resolution: Hatch seals were renewed, and tested all sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 March 2017 Resolved
Engine room bilge high level alarm is in operable. Replace/repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2017
Resolution: New alarm was installed and tested. Sat.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 23 March 2017 Resolved
Fireboy system does not alarm or secure engine upon "simulated" discharge. Replace/repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2017
Resolution: New system was installed and tested all sat.
Engineering › Fuel Oil Service System › Valve
Issued 23 March 2017 Resolved
Remote fuel shut-off valve on port fuel tank is inoperable. Renew valve, and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2017
Resolution: NEw valve handles were installed and tested all sat.
Lifesaving › Lifefloat › Serviceable
Issued 23 March 2017 Resolved
Life float grablines and reflective material are wasted and must be replaced.
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 10 April 2017
Resolution: New grablines were installed, and new reflective tape was installed.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 23 March 2017 Resolved
Float light batteries are extinguished. Renew.
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 10 April 2017
Resolution: new batteries were installed and tested all sat.
Fire Fighting › Fire Bucket › Availability
Issued 23 March 2017 Resolved
Fire buckets are not onboard.Provide 3, 2.5 gallon buckets.
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 10 April 2017
Resolution: Buckets were provided.
Lifesaving › Lifebuoys › Approval
Issued 23 March 2017 Resolved
Life ring retro teape is wasted and must be replaced.
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 10 April 2017
Resolution: New SOLAS aproved reflective tape was installed.
Navigation › Piloting/Steering › Marine Charts
Issued 17 February 2012 Resolved
Provide up to date chart, coast pilot, and CG light list, on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 16 March 2012
Resolution: New chart, coast pilot and light list on board.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 February 2012 Resolved
Provide two additional adult life jackets on board. Vessel must reduce passenger count by 2 until new life jackets are provided on board.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 16 March 2012
Resolution: 2 new life jackets on board, all sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 February 2012 Resolved
Provide sign to indicate life jackets stowed in forward cabin, at cabin door.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 16 March 2012
Resolution: New sign installed, all sat.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 February 2012 Resolved
Remove or replace engine room hatch sound proof insulation, deteriorated and pieces falling into bilge. May clog bilge suction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 16 March 2012
Resolution: Insulation removed, may install new insulation in future.
Stability › Watertight Integrity › General
Issued 17 February 2012 Resolved
Install additional latch on engine hatches, one latch will not hold hatches securely down.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 March 2012
Resolved 16 March 2012
Resolution: New latch installed. Tested sat.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 March 2010 Resolved
Light list on board last updated in 2004, update light list to present day.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 April 2010
Resolved 23 March 2010
Resolution: Updated light list on board.
Lifesaving › Hand Flares › Not on Board
Issued 22 March 2010 Resolved
Provide 6 orange smoke signals on board.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2010
Resolution: 6 new orange smoke signals provided on board.
Lifesaving › Lifefloat › Lifeline
Issued 22 March 2010 Resolved
Both life line holders are wasted and may cause failure in releasing the life floats. Rpair or renew life line holders. Vessel may use only one life line for both life floats as discussed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2010
Resolution: New life float life line holder installed, both life floats attached to one life line. All sat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 22 March 2010 Resolved
Provide means to lock sewage overboard valve in closed position.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2010
Resolved 23 March 2010
Resolution: Lock installed on sewage overboard discharge valve.
Engineering › Bilge Water Management System › Valve
Issued 22 March 2010 Resolved
Provide positive closing valve on electric bilge pump discharge line at the hull, for toilet drain bilge pump.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2010
Resolved 23 March 2010
Resolution: New valve installed on bilge pump discharge line.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 22 March 2010 Resolved
Bonding wire is broken at port rudder post, repair bonding wire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2010
Resolved 23 March 2010
Resolution: Bonding wire on port rudder repaired.
Communications › Alarms/Indicators › High Water Alarm
Issued 24 May 2006 Resolved
Prove audible alarm for high bilge level alarm and label visual indictors.
Action required: 705 - Other - as specified
Due 25 June 2006
Resolved 26 May 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 24 May 2006 Resolved
Prove annual servicing on all fire extinguishing equipment prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2006
Lifesaving › Lifefloat › Paddle
Issued 2 June 2005 Resolved
Provide 2 paddles (minimum 4 ft. in length) for eack Lifefloat.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 10 June 2005
Resolution: Completed.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 2 June 2005 Resolved
Provide and post Emergency Radio Broadcast Placard.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 10 June 2005
Resolution: Completed.
Lifesaving › Hand Flares › Marking
Issued 2 June 2005 Resolved
Properly stencil watertight container for distress signals.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 10 June 2005
Resolution: Completed.
Documentation › Logs/Records › Logbook (official)
Issued 2 June 2005 Resolved
Provide a logbook for conducting emergency drills and testing EPIRB.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 10 June 2005
Resolution: Completed.
Lifesaving › Lifefloat › Float-free Link
Issued 2 June 2005 Resolved
Install one additional painter & weak link for Lifefloat or install proper size weak link.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 10 June 2005
Resolution: Completed.
Lifesaving › Lifefloat › Float Free
Issued 2 June 2005 Resolved
Install spacers in between Lifefloats.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 10 June 2005
Resolution: Completed.
Documentation › Certificates/Documents › Stability Letter
Issued 2 June 2005 Resolved
Provide and post Stability Letter.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 25 July 2005
Operations/Management › Drills/Instruction › Abandon Ship
Issued 2 June 2005 Resolved
Post Lifejacket Donning Placard.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 10 June 2005
Resolution: Completed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.