Records from 2005 to 2020. Most recent: inspection, 2 December 2020.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 2 December 2020
No resolution recorded
MARPOL ANNEX 1 REG 6.3.4
In every case the Administration concerned shall fully guarantee the completeness of the survey. IOPP certificated denotes MEPC.107 oily water seprator. Vessel is equipped with a MEPC.60
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021 — due date passed with no resolution recorded
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 24 March 2010
Resolved
33CFR155.1015 - Forgien vessels operating on the navigable waters of the United States. Vessel does not have a Vessel Response Plan.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 March 2010
Resolved 8 April 2013
Resolution: Vessel has approved Vessel Response Plan on board.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 24 March 2010
Resolved
1540 - Gyro Compass
Vessel must have a gyro compass repeater in emergency steering position. Vessel did not have gyro compass repeater at the emergency steering position.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 March 2010
Resolved 25 March 2010
Resolution: Installed a new gyro compass repeater at the emergency steering position.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 24 March 2010
Resolved
0710 - Fire Prevention
Surfaces with tempatures above 220 C which maybe impinged as a result of a fuel system failure shall be properly insulated. Middle generator exhaust manifold not properly insulated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2010
Resolved 25 March 2010
Resolution: Placed lagging on the middle generator exhaust manifold.
Lifesaving › Lifeboat Equipment › Radio (fixed two-way VHF radio-telephone)
Issued 24 March 2010
Resolved
0670 - Portable radio app. for survival craft.
GMDSS radios must have back up batteries. GMDSS radios spare batteries were past the expiration date.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2010
Resolved 25 March 2010
Resolution: Purchased new radios and batteries.
Electrical › Electric Generation Source (emergency) › Generator
Issued 24 March 2010
Resolved
9800- Clearly Hazardous
SOLAS (2004CONS) CH II-1 REG 45.2 - Non conductive mats or gratings must be placed on the deck in the emergency generator room. Non conductive mats or gratings provided at the front + rear of the emergency switch board.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2010
Resolved 24 March 2010
Resolution: Purchased new non conductive mats for the entire room.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 24 March 2010
Resolved
0720 - Fire Fighting Equipment
Fire-Fighters outfits shall comply with the Fire Safety Systems Code. SCBA leaked air during the fire drill due to regulatory failure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2010
Resolved 25 March 2010
Resolution: Fixed the regulators on the SCBA''''s.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 24 March 2010
Resolved
9900 - Other (not clearly hazardous)
Unless exempted in 151.2010 or 151.2015, this subpart applies to all vessels, U.S. and foreign, equipped with ballast tanks, that operate in the waters of the United States and are bound for ports or places in the United States. Vessel did not have a Ballast Water Management Plan.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 March 2010
Resolved 8 April 2013
Resolution: Vessel had Ballast Water Management Plan on board.
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 24 March 2010
Resolved
0699 - Other (life saving appliance)
Vessel must be outfitted with an Long Range Identification and Tracking. Vessel did not have an Long Range Identification and Tracking.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 March 2010
Resolved 31 March 2015
Resolution: Vsl had onboard a LRIT and associated documentation.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 24 March 2010
Resolved
1499- other (Prop. & Aux. Machinery)
Vessel was unable to start emergency generator using secondary means.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2010
Resolved 25 March 2010
Resolution: Vessel bought appropriate tools to start emergency generator using secondary means.