Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)46.6 ft × 16.1 ft × 4.4 ft
Registered tonnagegross 23 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE WELDING & REPAIR WORKS INC · GREENVILLE, MS, UNITED STATES · built 1958
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKEOTA, OK
Endorsements, as the file codes themcw_un
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Gross Ton 16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 13 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 22 April 2025Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. During the inspection the generator was found to have exposed rotating machinery. A guard or rail must be placed around the exposed rotating machinery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2025
Resolved 16 May 2025
Resolution: A new guard was placed to protect people from rotating machinery.
While reviewing the vessels watertight and weathertight integrity, two watertight doors were found to have missing or worn gasket material. Gasket material must be replaced to ensure the vessels water and weather tight integrity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2025
Resolved 16 May 2025
Resolution: New gaskets were put in place.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2023Resolved
The Employee Assistance Program was not posted onboard the vessel (informative material, hot-line #, employer's policy).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 2 May 2023
Resolution: Policy was printed and posted onboard the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2023Resolved
The employer was not able to produce evidence of membership in good standing with a sponsoring organization for chemical testing management.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 2 May 2023
Resolution: Membership in a consortium (Mercy Health) confirmed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2023Resolved
No machinery alarms were installed at the operating station of the vessel. Vessel will need specific alarms (or summary alarm) for the following items: Main Engine low oil pressure & high engine temp, Aux Generator low oil pressure & high engine temp, and low hydraulic for steering. Bilge alarm is satisfactory and vessel is not equiped with a day tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 9 June 2023
Resolution: Machinery alarms installed.
The vessel's starboard main steering post/stock was observed allowing excess water to intrude onto the deck while maneuvering under power.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 9 June 2023
Resolution: Rudder post repaired.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 16 March 2021Resolved
Fire pump suction inoperable
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2021
Resolution: Replaced fire pump suction
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 16 March 2021Resolved
Missing Bilge Alarms
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2021
Resolution: Inspected adn tested installed alarms.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 16 March 2021Resolved
Missing Smoke detectors in Accommodation spaces
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 30 March 2021
Resolution: Installed smoke alarms
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 16 March 2021Resolved
General Alarm Inoperable
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 30 March 2021
Resolution: Repaired general alarm.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 March 2021Resolved
Extension cord used in semipermanent service, worn through and exposed wire
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 30 March 2021
Resolution: Removed extention cord.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 March 2021Resolved
Install Lagging on exhaust stacks on main deck and in engine room
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 30 March 2021
Resolution: Installed lagging on piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2021Resolved
Missing Check valve on bilge discharge
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 30 March 2021
Resolution: Inspected installed check valve near hull penetration.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.