MAURY USCG vessel records
← All vessels

ACADIA

ACADIA is a 1982 freight barge. The Coast Guard has recorded 3 inspections in 2005, along with 3 deficiencies.

Records in 2005. Most recent: inspection, 30 August 2005.

Built
1982
Last inspected
30 August 2005
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 30 August 2005
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2005)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

746139
Flag
UNITED STATES
Maury page id
psix-746139

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

30 August 2005 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2479497
18 July 2005 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2431256
25 April 2005 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2342746

Deficiency record · 3

Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 July 2005 Resolved
Portable fire extinguishers have not been serviced in the past year.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 30 August 2005
Resolution: Received written confirmation that fire extinguishers had been serviced.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 21 July 2005 Resolved
Install small discharge containment around fuel tank vent IAW 33 CFR 155.320. Fuel tank capacity: 40k gallons.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 30 August 2005
Resolution: Received written confirmation that small discharge containment was now installed.
Stability › Watertight Integrity › General
Issued 21 July 2005 Resolved
De-water rake and voids and ascertain source of water intrusion into tanks prior to load line exemption being issued.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2005
Resolved 22 July 2005
Resolution: Rake was dewatered and hole located and repaired.

Ownership record