Records from 2005 to 2008. Most recent: inspection, 22 October 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
22 October 2008
MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3345472
24 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2938787
3 May 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2921124
14 April 2007
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2907866
1 June 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2666730
13 May 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2646144
21 April 2006
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2628771
6 January 2006
NPV Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2561717
19 October 2005
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2517308
15 August 2005
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2463129
27 July 2005
Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2442273
27 July 2005
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2485972
13 June 2005
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2388148
29 April 2005
Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2362917
27 April 2005
PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2344575
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 22 October 2008
No resolution recorded
Offgoing 2nd Engineer sailed for 22 days without proper Falg State Endorsement. SMS procedures not followed by Company/Crewing Agency/ or Master. Recommend audit of the Companie's SMS procedures in regards to crew licensing.
ISM Code Reg. 6
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2008 — due date passed with no resolution recorded
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 22 October 2008
No resolution recorded
The fire safety suits are worn and damaged by storage and use. Damage includes: Severely torn glove, torn boot cover, Suits outer protective layer is worn from chafing while in storage. Replace with fire safety suits. SOLAS 74/78 Amended (1992 Consolidated) CH. II-2 Reg. 17.1
Action required: 705 - Other - as specified
Due 5 November 2008 — due date passed with no resolution recorded
Construction/Loadline › Structures › Door
Issued 22 October 2008
No resolution recorded
The following fire doors do not meet the requirements for preventing the passage of smoke and flame:
1) 108 office mess: does not close properly 2) 106 office door leading into the ships office: lock missing 3) Multiple doors in the stair well are missing are missing locks. repair or replace fire doors. SOLAS 74/78 Amended (1992 Consiladeted) CH. II-2 Reg 47
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2008 — due date passed with no resolution recorded
Personnel › Training › Familiarization Training
Issued 22 October 2008
Resolved
On 22-23 July 2008, Vessel had a crew swap that consisted of more than 25% requiring the vessel to complete drills within 24 hours of the ship departing. These drills were not conducted until 12AUG2008. SOLAS 74/78 Amended (2004 Consilidated) CH. III Reg. 19.3.2
Action required: 705 - Other - as specified
Resolved 22 October 2008
Resolution: Deficiency rectified on spot.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 22 October 2008
No resolution recorded
Vessel has one outstandiing def. that can not be verified as having been corrected to the satisfaction of class. Def. as follows: " found dead end wires in way of starboard gangway winch that was removed. Instructed master to remove or make permanent repairs at next dry-dock scheduled in July". Repair or confirm that this has been corrected to class.
Action required: 705 - Other - as specified
Due 21 November 2008 — due date passed with no resolution recorded
Communications › Radio Communications › Satellite Communications Capability
Issued 22 October 2008
No resolution recorded
The Vessels Navtex reciever is non-operational. SOLAS 74/78 Amended (2004 Consolidated) CH. IV Reg. 7.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 November 2008 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 3 May 2007
No resolution recorded
Found dead end wires in way of the starboard gangway winch that was removed. Instructed master to remove or make permanent repairs at next drydock scheduled in July.
Action required: 705 - Other - as specified
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 May 2007
Resolved
Found fire control plans not marked with the vessel name. Correct to the satisfaction of USCG.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 May 2007
Fire Fighting › Means of Escape › Blocked
Issued 3 May 2007
Resolved
Found emergency exit for the emergency generator room blocked.
Due 4 May 2007
Resolved 4 May 2007
Engineering › Steering Gear System › Pin
Issued 3 May 2007
Resolved
Found rocker arm on the steering gear not double bolted or with a cotter pin.
Due 4 May 2007
Resolved 4 May 2007
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 21 April 2006
Resolved
Found fireman's outfit (helmet) not fully protecting all exposed skin. Prove to satisfaction of class society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 June 2006
Resolution: Found new fully encapsulated fireman outfits on board the vessel with supporting class society report documentation.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 21 April 2006
Resolved
Found fire doors throughout vessel not operational. Prove to the satisfaction of class society.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2006
Resolution: Reviewed class survey report and spot checked all fire doors, all found operational.
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 April 2006
Resolved
Found vessel with no U.S. Coast Pilot on board. Prove to U.S. Coast Guard satisfaction that vessel has book.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 June 2006
Resolution: Captain proved vessel had an alternate publication of British Admiralty to replace U.S. Coast Pilot as per 33 CFR 164.33(b).
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 21 April 2006
Resolved
Found fire doors to engine room not operational. Prove proper operation and material condition to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2006
Resolution: Reviewed class survey report and spot checked all engine room fire doors, all found operational.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 21 April 2006
Resolved
Found Oily Water Separator not operating properly. Prove proper operation to satisfaction of class society.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2006
Resolution: Reviewed class survey report and spot checked oily water separator all found operational.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 April 2006
Resolved
Found temporary repairs (softpatch) made to an electrical conduit at frame 25 of the main deck. Make permanant repairs to the satisfaction of class society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 May 2006
Resolution: Reviewed class survey report and spot checked repairs to electrical conduit, found it satisfactory.
Lifesaving › Lifeboat › Hull
Issued 19 October 2005
Resolved
Found top starboard lifeboat cover with a temporary repair to a crack. Make permanent repairs to lifeboat cover to the satisfaction of class.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 October 2005
Resolved 31 October 2005
Resolution: Reviewed survey statement from class that all repairs had been completed and witnessed by class.
Deck/Cargo › Ballast › Tank
Issued 27 July 2005
Resolved
During de-ballasting operation from the stern ballast tank fuel oil was discharged. Issued requirement to inspect and verify that ballast and fuels tanks are not cracked or fractured.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 August 2005
Resolution: Received class report that the vessel made repairs to number 4 HFO tank.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 27 July 2005
Resolved
Issued requirement to not conduct ballast water transfers in U.S. waters due potential fuel oil contamination.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 July 2005
Resolved 15 August 2005
Resolution: Received class report that repairs to number 4 HFO tank were completed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 April 2005
Resolved
Waterlights not fitted on one-half of the required lifebuoys onboard.
Condition: Improper Installation
Due 30 May 2005
Resolved 11 June 2005
Resolution: Completed.