MAURY USCG vessel records
← All vessels

SWIFT

SWIFT is a 1958 towing vessel. The Coast Guard has recorded 15 inspections since 1992, most recently in July 2026, along with 24 deficiencies and 1 operational control.

Records from 1992 to 2026. Most recent: inspection, 23 July 2026.

Built
1958
Last inspected
23 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 23 July 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (1992–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ9534
Flag
UNITED STATES
Maury page id
psix-74659

Documentation record

Registered dimensions (L × B × D)60.3 ft × 17.2 ft × 8.4 ft
Registered tonnagegross 58 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNKNOWN · JACKSONVILLE FL, UNITED STATES · built 1958
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW HAVEN, CT
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
27 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

15 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

23 July 2026 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8444904
7 August 2025 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8204558
15 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7977776
6 September 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7784982
12 July 2022 Deficiency Check · Initial Certification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7433392
14 September 2017 Deficiency Check · Industry Initiated Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6267416
20 June 2017 Industry Initiated Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6188522
6 April 2016 Administration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5848410
15 October 2009 DAPI Audit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3615482
8 October 2009 Industry Initiated Exam · MARPOL · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3613821
11 February 2009 Type not recorded
No type recorded · Station New London · USCG Northeast District (CGD-NE) · Activity 3416721
3 February 2009 Administration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3412359
11 May 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2354905
6 December 2001 Type not recorded
No type recorded · USCGC ADAK (WPB 1333) · USCG Northeast District (CGD-NE) · Activity 1523942
23 September 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 61766

Deficiency record · 24

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 August 2024 Resolved
Re-label fuel shut off valves (marking is wearing off). Each remote valve control must be marked in clearly legible letters at least 1in high, indicating the purpose of the valve and the way to operate it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 11 October 2024
Resolution: verified completed
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 August 2024 Resolved
Attach liferaft to vessel. Each liferaft must have a painter system providing a connection between the vessel and the liferaft. Prior to towing ops. 46 CFR 141.310 -> 199.130(6)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 August 2024 Resolved
Ring life-buoy on the port side has deteriorated grab line (came apart when MI tested it). Provide buoy of at least 24" in diameter and with grab line (approved under 160.050 or 160.150). Prior to towing ops.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2024 Resolved
The floating electric water light attached to the ring life buoy must have a lanyard of at least 3ft, but no more than 6ft in length securing the light around the body of the buoy. Lanyard was approx 12in long.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 28 August 2024
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2024 Resolved
Stbd main engine has an exhaust leak. Remove lagging and identify where the leak is coming from, and fix.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 11 October 2024
Resolution: verified completed
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 August 2024 Resolved
MI identified a soft patch on 2nd deck forward at the top of the ladder. Crop and renew (ensuring to good metal) to maintain watertight integrity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 11 October 2024
Resolution: verified completed
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 August 2024 Resolved
High bilge level alarm at the operating station had no audible alarm. Alarms must be visible and audible. Provide audible alarm for high bilge level.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 28 August 2024
Resolution: completed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 August 2024 Resolved
Vessels stbd engine room door has fractured glass. When MI pressed on it, it gave slightly. Renew material, or conduct testing so that the watertight integrity of the vessel is maintained.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 11 October 2024
Resolution: completed test sat
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 August 2024 Resolved
Vessels log does not have any drills recorded. Conduct drills and record in vessel log.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 28 August 2024
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 August 2024 Resolved
Vessel on lakes, bays and sounds route within 3 miles of shore are required 3 day and 3 night flares. Vessels day signals expire 8/2024, and night flares expire 9/2024. Replace flares by expiry dates.
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 August 2024 Resolved
Vessels Firefighting was serviced Aug2023. Provide proof of servicing for 2024.
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2024 Resolved
Remove or mount extra portable fire ext bottles in the fwd stbd crew area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 August 2024 Resolved
Smoke detectors are required in berthing areas. Only one berthing area had a smoke detector. (May have been removed to renew the battery.) Provide approved smoke detectors in berthing areas (must meet UL 217).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 28 August 2024
Resolution: completed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 September 2023 Resolved
Vessel must have valid Certificate of Documentation (COD). COD on board expired 8/31/2023, and new one could not be located. Provide copy of COD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 14 September 2023
Resolution: rec'd copy of COD, original on board
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 September 2023 Resolved
Marine Inspector witnessed that port and starboard shafts had steady stream of water pouring from them, causing auto bilge pump to operate frequently. Tighten shaft to reduce water leaking into bilge. Complete prior to any towing evolutions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2023
Resolved 18 September 2023
Resolution: completed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 September 2023 Resolved
Prior to getting underway the master or officer in charge of a navigational watch of the vesselmust examine and test the steering gear, signaling whistle, porpulsion control, towing gear, nav lights, nav equip, and comm systems of the vessel. This examination does not need to be conducted more than once in any 24hr period. Results must be recorded in the TVR or official logbook. No entries have been made, no records of ever completing prior to getting underway. Provide completed entry prior to operating as towing vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2023
Resolved 18 September 2023
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 July 2022 Resolved
Prove proper operation of bilge system. System could not be operated at time of COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2022
Resolution: complete
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 July 2022 Resolved
Provide visual indicator for bilge alarm. Must be visible at operating station. Vessel had an audible but no visual bilge high level indicator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 27 July 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022 Resolved
Regarding Ring Life Buoys: 2 ring life buoys must have a waterlight attached by a line 3'-6' in length.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 22 July 2022
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 July 2022 Resolved
Each towing vessel must be equipped with at least one fire ax, accessible from exterior of vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 22 July 2022
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 July 2022 Resolved
Each remote fuel shut-off control must be marked with how to operate it. Remote shut-offs were labeled, but no indication on operation (whether closing or opening). Mark each shut off valve with operating indicators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 22 July 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2022 Resolved
Provide lifejackets for all persons on board. Vessel had 5 PFD's and needs 6.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 27 July 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 July 2022 Resolved
Provide immersion suits for all persons on board. Vessel had 5 and needs 6.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 27 July 2022
Resolution: completed
Documentation › Logs/Records › MIS Form
Issued 15 October 2009 Resolved
Company representative obtained MIS data from consortium, but failed to submit reports to USCG.
Due 15 November 2009
Resolved 15 October 2009
Resolution: DER contacted USCG HQ program manager to submit previous reports and initiate submittal of further reports.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.