Records from 1992 to 2026. Most recent: inspection, 23 July 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 15
23 July 2026
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8444904
7 August 2025
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8204558
15 August 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7977776
6 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7784982
12 July 2022
Deficiency Check · Initial Certification
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7433392
14 September 2017
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6267416
20 June 2017
Industry Initiated Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6188522
6 April 2016
Administration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5848410
15 October 2009
DAPI Audit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3615482
8 October 2009
Industry Initiated Exam · MARPOL · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3613821
11 February 2009
Type not recorded
No type recorded · Station New London · USCG Northeast District (CGD-NE) · Activity 3416721
3 February 2009
Administration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3412359
11 May 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2354905
6 December 2001
Type not recorded
No type recorded · USCGC ADAK (WPB 1333) · USCG Northeast District (CGD-NE) · Activity 1523942
23 September 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 61766
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 August 2024
Resolved
Re-label fuel shut off valves (marking is wearing off). Each remote valve control must be marked in clearly legible letters at least 1in high, indicating the purpose of the valve and the way to operate it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 11 October 2024
Resolution: verified completed
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 August 2024
Resolved
Attach liferaft to vessel. Each liferaft must have a painter system providing a connection between the vessel and the liferaft. Prior to towing ops.
46 CFR 141.310 -> 199.130(6)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 August 2024
Resolved
Ring life-buoy on the port side has deteriorated grab line (came apart when MI tested it). Provide buoy of at least 24" in diameter and with grab line (approved under 160.050 or 160.150). Prior to towing ops.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2024
Resolved
The floating electric water light attached to the ring life buoy must have a lanyard of at least 3ft, but no more than 6ft in length securing the light around the body of the buoy. Lanyard was approx 12in long.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 28 August 2024
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2024
Resolved
Stbd main engine has an exhaust leak. Remove lagging and identify where the leak is coming from, and fix.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 11 October 2024
Resolution: verified completed
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 August 2024
Resolved
MI identified a soft patch on 2nd deck forward at the top of the ladder. Crop and renew (ensuring to good metal) to maintain watertight integrity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 11 October 2024
Resolution: verified completed
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 August 2024
Resolved
High bilge level alarm at the operating station had no audible alarm. Alarms must be visible and audible. Provide audible alarm for high bilge level.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 28 August 2024
Resolution: completed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 August 2024
Resolved
Vessels stbd engine room door has fractured glass. When MI pressed on it, it gave slightly. Renew material, or conduct testing so that the watertight integrity of the vessel is maintained.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 11 October 2024
Resolution: completed test sat
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 August 2024
Resolved
Vessels log does not have any drills recorded. Conduct drills and record in vessel log.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 28 August 2024
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 August 2024
Resolved
Vessel on lakes, bays and sounds route within 3 miles of shore are required 3 day and 3 night flares. Vessels day signals expire 8/2024, and night flares expire 9/2024. Replace flares by expiry dates.
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 August 2024
Resolved
Vessels Firefighting was serviced Aug2023. Provide proof of servicing for 2024.
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2024
Resolved
Remove or mount extra portable fire ext bottles in the fwd stbd crew area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2024
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 August 2024
Resolved
Smoke detectors are required in berthing areas. Only one berthing area had a smoke detector. (May have been removed to renew the battery.) Provide approved smoke detectors in berthing areas (must meet UL 217).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2024
Resolved 28 August 2024
Resolution: completed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 September 2023
Resolved
Vessel must have valid Certificate of Documentation (COD). COD on board expired 8/31/2023, and new one could not be located. Provide copy of COD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 14 September 2023
Resolution: rec'd copy of COD, original on board
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 September 2023
Resolved
Marine Inspector witnessed that port and starboard shafts had steady stream of water pouring from them, causing auto bilge pump to operate frequently. Tighten shaft to reduce water leaking into bilge. Complete prior to any towing evolutions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2023
Resolved 18 September 2023
Resolution: completed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 September 2023
Resolved
Prior to getting underway the master or officer in charge of a navigational watch of the vesselmust examine and test the steering gear, signaling whistle, porpulsion control, towing gear, nav lights, nav equip, and comm systems of the vessel. This examination does not need to be conducted more than once in any 24hr period. Results must be recorded in the TVR or official logbook. No entries have been made, no records of ever completing prior to getting underway. Provide completed entry prior to operating as towing vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2023
Resolved 18 September 2023
Resolution: completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 July 2022
Resolved
Prove proper operation of bilge system. System could not be operated at time of COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2022
Resolution: complete
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 July 2022
Resolved
Provide visual indicator for bilge alarm. Must be visible at operating station. Vessel had an audible but no visual bilge high level indicator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 27 July 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2022
Resolved
Regarding Ring Life Buoys: 2 ring life buoys must have a waterlight attached by a line 3'-6' in length.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2022
Resolved 22 July 2022
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 July 2022
Resolved
Each towing vessel must be equipped with at least one fire ax, accessible from exterior of vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 22 July 2022
Resolution: completed
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 July 2022
Resolved
Each remote fuel shut-off control must be marked with how to operate it. Remote shut-offs were labeled, but no indication on operation (whether closing or opening). Mark each shut off valve with operating indicators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 22 July 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2022
Resolved
Provide lifejackets for all persons on board. Vessel had 5 PFD's and needs 6.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 27 July 2022
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 July 2022
Resolved
Provide immersion suits for all persons on board. Vessel had 5 and needs 6.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 27 July 2022
Resolution: completed
Documentation › Logs/Records › MIS Form
Issued 15 October 2009
Resolved
Company representative obtained MIS data from consortium, but failed to submit reports to USCG.
Due 15 November 2009
Resolved 15 October 2009
Resolution: DER contacted USCG HQ program manager to submit previous reports and initiate submittal of further reports.