CHRIS GR is a 2005 freight ship. The Coast Guard has recorded 20 inspections since 2005, most recently in July 2025, along with 7 deficiencies and 2 operational controls.

Records from 2005 to 2025. Most recent: inspection, 27 July 2025.

Built
2005
Last inspected
27 July 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9284506 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA2939
746620
Flag
MALTA
—
Maury page id
psix-746620

Inspections, by type

…with no type recorded7
Years with a record 10 calendar years (2005–2025)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it63833 - Displacement, Metric Ton
55715 - Dead Weight, Metric Ton
30632 - Convention (Subpart B), Gross Ton
18525 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

27 July 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8187384
10 January 2019 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6608400
7 January 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6605138
4 January 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6605512
3 January 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6605275
29 October 2015 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5753638
25 September 2015 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5724689
13 August 2014 Ballast Water Examination · PII Safety Exam · ISPS II Exam · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4953538
10 August 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4949937
15 January 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4225053
28 December 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3912986
26 December 2010 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3916554
12 June 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3228396
28 January 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2862915
17 August 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2751587
27 July 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2726715
25 February 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2592010
11 May 2005 ISPS II Exam · PII Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2355450
3 May 2005 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2348759
24 February 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2591986

Deficiency record · 7

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 July 2025 Resolved
Where cables which are installed in hazardous areas introduce risk of fire or explosion. PSCO identified that port side deck electrical conduit links has multiple factures IWO junction boxes 1 thru 5. Conduct permanent repairs prior to conducting cargo. SOLAS 74 AM II-1/45 5.4 AC
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 July 2025
Resolution: Received, reviewed and accepted Class report from NKK attesting to the permanent repairs to the conduit boxes.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 7 January 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2019
Resolution: Replaced malfunctioning equipment
Electrical › Lighting (service) › Ground Detection
Issued 25 September 2015 Resolved
0830- Elelctrical – All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Lights in the engine room near the engine control room, workshop and in engine room have exposed wires protruding from the light.– SOLAS 74 (09) II-1/45.1.3 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 October 2015
Resolution: Vessel provided diagram from shipyard and a statement from Classification Society showing that that ground wires are used for all lighting cables. See Documents tab for copy of related documents and pictures.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 September 2015 Resolved
0650-LIFEBUOYS-not less then half of the totla number of lifebuoys shall be provided with lifebuoy self igniting lights complying with the code.01 self igniting light was inoperable and 02 were partially painted. SOLAS 74(14) III/7.1.3 - 10c
Action required: 705 - Other - as specified
Resolved 25 September 2015
Resolution: replaced battery and used sand paper to remove excess paint
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 13 August 2014 Resolved
0720: Protective clothing material to protect the skin from the heat radiating from the fire. 02 of the 04 firefighting outfits onboard show signs of excessive wear rendering them unfit for service. - SOLAS II-2/10.10.1 ; 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 August 2014
Resolved 13 November 2014
Resolution: Vessel provided certification from China [name withheld] attesting to the satisfactory inspection of fireman''s outfits.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 13 August 2014 Resolved
2535: Those ships using separate fuel oils to comply with emission control area requirements shall carry a written procedure showing how the fuel oil changeover is to be done. Current changeover procedures provided by the company do not adequately explain the steps needed to change from heavy fuel oil to marine diesel and back. - MARPOL VI/14.6 & ISM A/7; 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 August 2014
Resolved 13 November 2014
Resolution: Vessel provided fuel oil change over procedures with concurrence from their classification society.
Construction/Loadline › Hull › Hull Plating
Issued 28 December 2010 Resolved
Vessel shall maintain stability IAW LL Certificate. During cargo operations a grab bucket damaged port number one ballast water tank and number one cargo hold.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2011
Resolution: Received and reviewed classification report attesting that all repairs were tested with hydrostatic pressure and found satisfactory. All repairs were considered permanent.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.