MAKANI is a 2005 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in December 2025, along with 24 deficiencies and 2 casualty investigations between 2007 and 2011.

Records from 2007 to 2025. Most recent: inspection, 12 December 2025.

Built
2005
Last inspected
12 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 December 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC6709
746823
Flag
UNITED STATES
Maury page id
psix-746823

Documentation record

Registered dimensions (L × B × D)64.0 ft × 30.0 ft × 7.0 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGOLD COAST YACHTS INC · ST CROIX · built 2005
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 27 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

12 December 2025 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8251753
11 March 2025 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8092895
13 February 2025 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8079430
12 November 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7964593
12 February 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7847359
11 December 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7837695
28 February 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7634773
9 November 2022 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7563994
24 February 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7401715
14 December 2020 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7098783
4 November 2020 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7090013
17 December 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6875499
14 January 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6610087
6 November 2018 Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6577783
12 December 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6323416
12 December 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6056432
8 November 2016 Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6037576

Deficiency record · 24

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 February 2025 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station... An audible alarm that sounds upon discharge. The starboard side extinguishing system does not sound the audible alarm upon discharge. Restore in accordance with manufacturer's guidance to the satisfaction of the attending marine inspector. 46 CFR 181.420(b)(2)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 February 2025
Resolution: O/O installed new fireboy control panels and demonstrated operational test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 February 2025 Resolved
Each floating waterlight... must be attached to the lanyard with a corrosion-resistant clip. Waterlight on the primary lifering attached without corrosion resistant clip. Install as discussed to the satisfaction of the attending marine inspector. 46 CFR 180.70(d)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 13 February 2025
Resolution: O/O installed corrosion resistant clip.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 February 2024 Resolved
A fire pump must be capable of both remote operation from the operating station and local operations at the pump. Local switch inoperable. Replace switch and demonstrate proper operation to satisfaction of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2024
Resolution: Replacement switch installed and operational.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 12 February 2024 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Rotating belts on forward end of starboard engine are not covered or protected. Provide guard or cover for rotating parts of engine to the satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 February 2024
Resolved 12 February 2024
Resolution: Wire guards installed over rotating parts of engine.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2023 Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. All adult life-jackets retro-reflective material was wasted. Replace. 46CFR185.604(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2023
Resolution: Attending MI returned to vessel and re-inspected all life-jackets for retro-reflective material. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 February 2023 Resolved
If the vessel carries more than one life float or buoyant apparatus in a group with each group secured by a single painter: each life float and buoyant apparatus must be individually attached to the painter by a line long enough that each life float or buoyant apparatus can float without contacting any other life float or buoyant apparatus in the group. The second life float in the group was not individually attached to the painter. Attach second life float in group to the painter with a line long enough to not contact the other life float. Vessel is restricted to not more than 3 miles from shore until resolved to the satisfaction of the attending marine inspector. 46CFR180.137(e)(3)
Action required: 705 - Other - as specified
Resolved 11 April 2023
Resolution: Attended vessel and inspected the second life float in group with a painter line long enough to not contact the other life float. Route retriction lifted.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 28 February 2023 Resolved
A vessel must be fitted with a Federal Communications Commission (FCC) type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operating station if: the vessel has a limited coastwise route and carries more than 49 passengers. Vessel's radar was inoperable. Vessel's restricted to a Lakes, Bays, and Sounds route until resolved to the satisfaction of the attending marine inspector. 46CFR184.404(a)
Action required: 705 - Other - as specified
Resolved 11 April 2023
Resolution: Attended vessel and observed radar proper operation. Route restriction lifted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 February 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel identified examinations of rigging equipment in PMP, however vessel did not have a record of these examinations occurring at the prescribed intervals. Provide an examination record as per the vessel's PMP to the satisfaction of the attending marine inspector. 46CFR176.840
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 7 March 2023
Resolution: Received sail rigging examination record for February as per the vessel's PMP to the satisfaction of the attending marine inspector.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 28 February 2023 Resolved
Each sewage retention device must have a means of indicating when the device is more than 3/4 full by volume. The sewage tank level indicating gauge is unreadable. Replace gauge and prove operation to the satisfaction of the attending marine inspector. 33CFR159.83
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2023
Resolved 21 April 2023
Resolution: Received photograph from vessel rep of sewage tank level indicator installed and reading the tank level.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 February 2023 Resolved
Each vessel that does not demonstrate compliance in accordance with § 178.310(c) of this chapter must Have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. Vessel's current loading marks are not permanently installed. Make permanent at next drydock. 46CFR185.602(b),(c)(2)
Action required: 705 - Other - as specified
Resolved 13 February 2025
Resolution: Sighted loading marks installed on each side of the hull during the Annual Inspection
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2022 Resolved
A fire pump must be capable of both remote operation from the operating station and local operations at the pump. Vessel's fire pump inoperable. Vessel restricted to 49 passengers until proper operation of the fire pump is performed to attending marine inspector. 46 CFR 181.300(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 February 2022
Resolution: Vessel demonstrated proper operation of fire pump at 60psi
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2022 Resolved
Sail rigging and components are to be maintained in accordance with good marine practice. Observed chaffing in running rigging loops below boom. Replace running rigging. 46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 March 2022
Resolution: Vessel replaced running rigging. All Sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 February 2022 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. No indicator for automatic bilge pumps. Install visual indicator for automatic bilge pump system or install manual bilge pumps. 46 CFR 182.530(c)
Action required: 705 - Other - as specified
Resolved 9 November 2022
Resolution: Automatic pumping arrangment was removed.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 February 2022 Resolved
Except as provided in 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Vessel's FCC Safety Radiotelephony certificate expired. 47 CFR 80.405
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 March 2022
Resolution: Updated FCC certificate
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 February 2022 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel's red hand flare distress signals are expired. Replace expired distress signals. 46 CFR 180.68
Action required: 10 - Deficiency Rectified
Resolved 24 February 2022
Resolution: Replaced on the spot.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 December 2020 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing LAT/LONG for DSC operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 18 December 2020
Resolution: VHF has been appropriately wired with GPS input.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2020 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor insulation. Permanently installed cabin fans require overcurrent protection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 18 December 2020
Resolution: Installed cabin fans have been connected to overcurrent protection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2020 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Strainer was worn and needed replacing.
Action required: 10 - Deficiency Rectified
Resolved 14 December 2020
Resolution: Strainer was replaced in-kind.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 December 2020 Resolved
Each life float and buoyant apparatus weak link must be secured to the painter at one end and to the vessel on the other end. The weak link was connected to the painter on one end and then the railing course utilizing a rope and clip.
Action required: 10 - Deficiency Rectified
Resolved 14 December 2020
Resolution: Weak link was connected to the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2019 Resolved
Vessel does not have a Preventative Maintenance Plan (PMP) that specifically address their vessel's sail rigging equipment and components. Provide PMP IAW USCG NVIC 02-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2019
Resolved 23 January 2019
Resolution: Vessel rep submitted PMP IAW NVIC 02-16
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 January 2019 Resolved
On a vessel of at least 26 ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level; Vessel has one visual and audible indicator for port side and one for stbd side but the but the indicator does not indicate the location of the high water. Provide alarm and visual indicator for each space a high water alarm is located.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2019
Resolved 6 February 2019
Resolution: Vessel rep added new visual and audible indicators at steering console for high water alarms.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 January 2019 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating; Vessel automatic bilge pump visual indicators are not located at the operating station. Provide visual indicators at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2019
Resolved 8 February 2019
Resolution: Verified vessel rep removed the float swiches for all installed automatic bilge pumps, making them no longer automatic.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2018 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Provide an adequate means of protection on both port and starboard main engine auxiliary drives.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2018
Resolved 9 November 2018
Resolution: Vessel rep submitted pictures of protective guards around both M/E aux drives. All sat.
Engineering › Bilge Water Management System › Not Operational
Issued 12 December 2017 Resolved
Repair visual indicator for port high water alarm IAW 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 20 January 2018
Resolved 20 December 2017
Resolution: Received photo of working bilge high water alarm

Casualty record · 2

18 February 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2890996
21 May 2011Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 4018287
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.