MAURY USCG vessel records Sign in
← All vessels

MIZAR

MIZAR is a 2005 freight ship. The Coast Guard has recorded 27 inspections since 2005, most recently in December 2020, along with 6 deficiencies and 12 operational controls.

Records from 2005 to 2020. Most recent: inspection, 9 December 2020.

Built
2005
Last inspected
9 December 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9295505 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
747282
Flag
LIBERIA
—
Maury page id
psix-747282

Inspections, by type

…with no type recorded18
Years with a record 5 calendar years (2005–2020)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it16162 - Simplified, Gross Ton
6128 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

9 December 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7109166
6 December 2020 PSC A · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7106989
21 June 2020 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6982330
21 June 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6984042
7 June 2020 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6968859
28 October 2008 Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3352704
13 October 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3343870
10 September 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3054201
25 May 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2940031
3 May 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2921213
6 April 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2903125
19 February 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2874136
13 January 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2855136
6 January 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2851117
14 October 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2800352
8 October 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2795970
18 August 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2752295
17 August 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2751131
19 July 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2718529
16 June 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2681844
21 May 2006 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2653582
17 May 2006 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2651378
24 October 2005 NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2522786
22 October 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2519750
14 July 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2426224
6 May 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2350679
4 May 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2349385

Deficiency record · 6

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2020 Resolved
M/V MIZAR lost machinery propulsuion while underway from the Port of Willimington.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 7 December 2020
Resolved 8 December 2020
Resolution: Vsl corrected issued, Class report submitted. Vsl cleared to sail.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 6 December 2020 Resolved
Lifeboats must have a food ration totalling not less than 10,000 kj for each person the lifeboat is permitted to accomodate; rations shall be kept in airtight packaging. 14 out of 32 food rations lost their airtight vacuum seal. 74 SOLAS (14) III/34, LSA Code 4.4.8.12.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2020
Resolved 6 December 2020
Resolution: Lifted OP control, Deficiency Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 June 2020 Resolved
REGULATIONS TO ENSURE THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO SHIP OR PERSONS ON BAORD. VESSEL REPORTED A LOSS OF PROPULSION WHILE MOORING AT THE PIER ON ARRIVAL. MAKE PROPER REPAIRS AND PROVIDE CLASS REPORT ADDRESSING THE CAUSATIVE FACTORS AND CORRECTIVE MEASURES.74SOLAS(14) I/11
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 June 2020
Resolution: PSCO reviewed submitted class report for replacement parts. Class conducted successful test of stern propulsion.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 7 June 2020 Resolved
All electrical auxiliar services necessary for maintaining the ship in normal operational and habitable conditions will be ensured. Found ventilation in the paint store inoperable. - 74 SOLAS (04) II-1/40.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2020
Resolved 6 July 2020
Resolution: Recieved report from Master attesting to proper operation of ventilation system with photos.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 May 2007 Resolved
Ship is fitted with two radars. One is inoperable due to problems with the tuning feature. The second radar is operating.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 May 2007
Resolved 27 May 2007
Resolution: Recieved tech report attesting to repair of radar.
Navigation › Collision/Grounding Avoidance › Radar
Issued 22 October 2005 Resolved
Demonstrate or send tech report attesting to the proper operation of second marine radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2005

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.