MAURY USCG vessel records
← All vessels

NAVIOS ASTERIKS

NAVIOS ASTERIKS is a 2005 freight ship. The Coast Guard has recorded 14 inspections since 2016, most recently in October 2024, along with 6 deficiencies — 1 with no resolution recorded — and 3 operational controls, 1 with no removal date recorded.

Records from 2016 to 2024. Most recent: operational control imposed, 14 October 2024.

Built
2005
Last inspected
14 October 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 October 2024
…with no type recorded1
Operational controls 1 with no removal date recorded
Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9304253
3E3421
748018
Flag
PANAMA
Maury page id
psix-748018

Documentation record

Tonnage as PSIX records it76801 - Dead Weight, Metric Ton
87409 - Displacement, Metric Ton
40014 - Convention (Subpart B), Gross Ton
25301 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

14 October 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8019506
11 October 2024 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8016851
2 November 2023 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7814491
31 October 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7818209
19 January 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7623865
24 December 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7612788
9 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7446868
18 March 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7404427
13 December 2021 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7367028
26 April 2021 PSC B · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7178911
12 January 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6609401
6 November 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6569363
28 June 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6181345
9 November 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6032853

Deficiency record · 6

10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 14 October 2024 No resolution recorded
ALL SHIPS OF 3000 GROSS TONNAGE AND UPWARDS, SHALL... HAVE A 3 GHZ RADAR OR, WHERE CONSIDERED APPROPRIATE BY THE ADMINISTRATION, A SECOND 9 GHZ RADAR. VESSEL CREW DISCOVERED THAT THE 3 GHZ, S-BAND RADAR WAS INOPERABLE WHILE CONDUCTING PRE-DEPARTURE CHECKS IN SEATTLE, WA ON 13OCT24. -SOLAS 74 (2014 CONS) V/19.2.7.1 . 40AC
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 11 October 2024 Resolved
74SOLAS(2009 ED) II-2/9.1.3 16a,c The fire integrity shall be maintained at openings and penetrations. The fire integrity of the division of the electrical equipment room was not maintained at 03 penetrations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 October 2024
Resolved 8 January 2025
Resolution: Received class report from [name withheld] stating deficiency has been rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2022 Resolved
13199 - Other (machinery) - The machinery boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO's observed filed temporary repairs to ballast piping, sea water cooling piping heat exchanger piping for main engine and generators and cascade tank and condenser piping. SOLAS 74(04) II-1/26.1-17ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2022
Resolved 24 December 2022
Resolution: Received, reviewed and accepted class report from LR stating that the leaking had been repaired to their satisfaction by clamps and cement boxes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 April 2021 Resolved
It was reported that htere was a MDE slow down due to a spike in cooling water temperature. Class to attest to operational readiness of MDE jacket water and lube oil cooler.
Action required: 60 - Rectify deficiencies prior to movement
Due 26 April 2021
Resolved 27 April 2021
Resolution: Received, reviewed and accepted class report from Llloyds attesting to the proper operation of the Main Diesel Engine jacket water and lube oil coolers.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 26 April 2021 Resolved
Ships Engineers were not capable of recovering data from OCM and displaying to PSCO iaw MEPC 107(49)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2021
Resolved 27 April 2021
Resolution: Received, reviewed and accepted class report from Lloyds attesting to ships engineers being provided with essentail familiarization training for OCM's subject to MEPC 107(49)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 November 2018 Resolved
Excessive Leaking on Fuel Oil Pump #6
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 11 November 2018
Resolved 11 November 2018

Ownership record