MAURY USCG vessel records
← All vessels

JOHN C

JOHN C is a 1958 towing vessel. The Coast Guard has recorded 8 inspections since 1996, most recently in January 2016, along with 31 deficiencies.

Records from 1996 to 2016. Most recent: inspection, 7 January 2016.

Built
1958
Last inspected
7 January 2016
Documentation
No Operation - PM · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 7 January 2016
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 4 calendar years (1996–2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE6332
Flag
UNITED STATES
Maury page id
psix-74942

Documentation record

Registered dimensions (L × B × D)38.6 ft × 12.1 ft × 4.1 ft
Registered tonnagegross 17 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLASGOW, MO, UNITED STATES · built 1958
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBEARDSTOWN, IL
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Regulatory (Subpart C or D), Gross Ton
11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

7 January 2016 Administration
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5792708
12 March 2013 Administration
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4547557
8 March 2013 Administration
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4545707
23 September 2008 Uninspected Other · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3331617
2 December 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 659013
19 November 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 195933
19 November 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 769108
18 November 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 397832

Deficiency record · 31

Communications › Audible Communications › Horn/Whistle
Issued 23 September 2008 Resolved
Prove proper operation of the vessel air horn. A temporary hand held air horn may be used until the vessel’s permanent horn is repaired.
Condition: Unknown
Due 1 April 2009
Resolved 2 April 2009
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 September 2008 Resolved
Ensure all portable fire extinguishers and the semi-portable B-V are serviced annually.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2008
Resolved 13 November 2008
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 September 2008 Resolved
Ensure the vessel has a serviceable type I, II or III PFD for each member onboard. Ensure the PFD’s are approved for commercial service on vessel of less than 40 feet.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2008
Resolved 13 November 2008
Fire Fighting › Fire Hoses › Condition
Issued 23 September 2008 Resolved
Ensure the vessel has a 50’ length of approved, 1.5 inch, lined, commercial fire hose.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2008
Resolved 13 November 2008
Fire Fighting › Fire Pumps › Arrangement
Issued 23 September 2008 Resolved
Ensure that the vessel’s portable fire pump, fire hose, pick-up hose and nozzle are not stored in the vessel’s engineroom.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2008
Resolved 13 November 2008
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 23 September 2008 Resolved
Prove proper operation of the installed engine room heat detection system.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2008
Resolved 13 November 2008
Stability › Unintentional Flooding › General
Issued 23 September 2008 Resolved
Properly repair the side shell hole in the aft engine room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2008
Resolved 13 November 2008
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 23 September 2008 Resolved
Remove all wood and debris from the engine room bilge and upper shaft ally.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2008
Resolved 13 November 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 September 2008 Resolved
Ensure the vessel’s name and hailing port is marked on the stern of the vessel in a minimum of 4’ letters.
Condition: Unknown
Due 1 April 2009
Resolved 2 April 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 23 September 2008 Resolved
Ensure the vessel has a current FCC radio station licenses and each master has an individual restricted radio operator permit.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 September 2008 Resolved
Ensure the vessel has approved, installed, navigation lights, as per 46CFR25.10. Vessel may operate in fair weather, daylight only, until the navigational lights are repaired.
Condition: Unknown
Due 10 November 2008
Resolved 13 November 2008
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 23 September 2008 Resolved
Prove proper operation of the bridge console engine water temperature and lube oil pressure gauge.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 23 September 2008 Resolved
Prove proper operation of the vessel’s search light. Vessel may operate in fair weather, daylight only, until the light is repaired.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 23 September 2008 Resolved
Install flame screens on the fuel tank vents.
Condition: Placed in Improper Service
Due 23 October 2008
Resolved 13 November 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 September 2008 Resolved
Re-route the port engine emergency fuel shut-off valve cable; it is currently a tripping hazard.
Condition: Unknown
Due 1 April 2009
Resolved 2 April 2009
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 23 September 2008 Resolved
Stencil the vessel’s name on the PFD’s and life ring
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Communications › Audible Communications › Bell
Issued 23 September 2008 Resolved
Create a pre-start up check-off sheet which includes testing of the vessel’s general alarm bell.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 23 September 2008 Resolved
Document (can use pre-start up check-off sheet) monthly man overboard and fire fighting drills.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 September 2008 Resolved
Properly support the bridge power supply cable located in the port side of the engine room. Needs to be secured with metal supports every 24 inches.
Condition: Placed in Improper Service
Due 23 October 2008
Resolved 13 November 2008
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 23 September 2008 Resolved
Post an oil discharge warning placard.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Pollution Prevention/Response › Prevention Equipment › Garbage Grinder/Comminuter
Issued 23 September 2008 Resolved
Post a garbage discharge (MARPOL) placard.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 September 2008 Resolved
Replace expired items in the vessel’s first aid kit.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 September 2008 Resolved
Guard or shield both main engines, lower pulleys.
Condition: Unknown
Due 10 November 2008
Resolved 13 November 2008
Engineering › Steering Gear System › Hydraulic Hose
Issued 23 September 2008 Resolved
Replace all chafed and deteriorated hydraulic steering hoses.
Condition: Unknown
Due 10 November 2008
Resolved 13 November 2008
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 23 September 2008 Resolved
Properly secure the engine starting batteries and bolt the grounding cable to the vessel hull.
Condition: Unknown
Due 10 November 2008
Resolved 23 September 2008
Communications › Alarms/Indicators › General Alarm
Issued 23 September 2008 Resolved
Post a sign for the engine room red G/A light: Attention, when alarm flashes go tot your station.
Condition: Placed in Improper Service
Due 1 April 2009
Resolved 2 April 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 23 September 2008 Resolved
Properly blanket (with approved insulation) both engine dry exhausts.
Condition: Placed in Improper Service
Due 1 April 2009
Resolved 2 April 2009
Operations/Management › Drug and Alcohol Testing › MRO Specified
Issued 23 September 2008 Resolved
Provide proof the company is using an approved MRO. Current MD is not an approved MRO. Arrangements need to be made to use the current consortium MRO.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 September 2008 Resolved
Post a local drug and alcohol assistance number and ensure the current consortium has access to a local SAP.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 23 September 2008 Resolved
Create a DOT drug testing background check form.
Condition: Unknown
Due 15 December 2008
Resolved 8 December 2008
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 September 2008 Resolved
Provide proof the supervisors have the required one hour EAP training.
Condition: Unknown
Due 23 October 2008
Resolved 13 November 2008

Ownership record