MAURY USCG vessel records Sign in
← All vessels

VASSOS

VASSOS is a 2004 freight ship. The Coast Guard has recorded 7 inspections since 2005, most recently in September 2020, along with 5 deficiencies and 1 operational control.

Records from 2005 to 2020. Most recent: inspection, 24 September 2020.

Built
2004
Last inspected
24 September 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9256872 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
749643
Flag
CYPRUS
—
Maury page id
psix-749643

Inspections, by type

…with no type recorded2
Years with a record 5 calendar years (2005–2020)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it26101 - Convention (Subpart B), Net Ton
86705 - Displacement, Ton
76015 - Dead Weight, Ton
40002 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

24 September 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7056557
2 November 2015 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5751117
16 August 2011 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4100539
13 June 2006 PII Safety Exam · MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2671225
19 May 2005 MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2361591
18 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2362358
14 May 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2357799

Deficiency record · 5

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2020 Resolved
ANY SHIP OF 10,000 GROSS TONNAGE AND ABOVE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT COMPLYING WITH PARAGRAPH 7 OF THIS REGULATION. DURING OPERATIONAL TESTING OF THE OWS, PSCO FOUND A LEAKING FLANGE ON THE SUPPLY LINE LEADING TO THE 3-WAY VALVE, RESULTING IN AN UNSATISFACTORY TESTING OF THE OWS. [name withheld] TO PROPER TESTING AND OPERATION OF THE OWS EQUIPMENT AND METER. MARPOL I/14.2, 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2020
Resolution: Received, reviewed, and accepted class and flag documentation. Vessel to make permanent repairs by 24NOV2020.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 November 2015 Resolved
1730- Oily Water Seperator Equipment - OWS not operating in compliance within MARPOL regulations. During operational testing of the OWS PSCO observed that the content meter could not indicate a sample below 30PPM. The freshwater flushing was not operational; ships crew was using bottled water to flush the oil content meter. MARPOL Annex I/14.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2015
Resolution: 05NOV2015: Received class report [name withheld] stating the deficiency was rectified. The class report stated: Attending suveryor tested OWS/OCM, using fresh water flushing in test mode and simulation mode, test were found satisfactory.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 November 2015 Resolved
0750- Fire Prevention -Structural fire protection, including fire resisting divisions, shall be kept in good order as to ensure their required performance if a fire occurs. Self closing A-60 fire door on the starboard side second deck would not close without crew assistance. SOLAS 74 (2014) II-2/14.2.1.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2015
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. E/R self closing door's tension was adjusted and tested multiple times in the presence of survery and found satisfactory.
Lifesaving › Inflatable Liferafts › Painter
Issued 2 November 2015 Resolved
0620- Inflatable Liferafts- Ship was not in all aspects fit to proceed to sea. Port side life raft had rubber material protruding from the life raft casing with the painter line attached. All other life rafts on board were in normal operating condition. Please provide clarification from certifiating authority attesting the proper operation of the port side life raft. SOLAS 74 (2014) I/11
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2015
Resolved 5 November 2015
Resolution: Received, reviewed and accepted class report [name withheld] stating the deficiency was rectified. Liferaft was a different model: SOLAS style TO, with bowline covered by rubber. This was confirmed by attending Surveryor on the Wilhemsen Service Manual.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 2 November 2015 Resolved
0750- Fire Prevention-Crew not maintaining a means to provide control of leaking flammable liquids. PSCO observed an excessive leak filled up to the top of the containment on the service tank diesel oil transfer pump. SOLAS 74 (2014) II-2/ 4.1.1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 November 2015
Resolved 5 November 2015
Resolution: Received, reviewed and accepted class report [name withheld] stating the deficiency was rectified. C/E stated Diesel Oil transfer pump packing on the stuffing box was renewed. Attending Surveyor tested the DO pump under pressure and found satisfactory.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.