MAURY USCG vessel records Sign in
← All vessels

TR CROWN

TR CROWN is a 2005 freight ship. The Coast Guard has recorded 22 inspections since 2005, most recently in September 2023, along with 15 deficiencies — 1 with no resolution recorded — and 7 operational controls.

Records from 2005 to 2023. Most recent: inspection, 19 September 2023.

Built
2005
Last inspected
19 September 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9322762 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
752988
Flag
MARSHALL ISLANDS
—
Maury page id
psix-752988

Inspections, by type

…with no type recorded6
Years with a record 10 calendar years (2005–2023)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it18486 - Convention (Subpart B), Net Ton
61965 - Displacement, Ton
53474 - Dead Weight, Ton
30002 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

19 September 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7789620
25 January 2023 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7622319
19 September 2022 Deficiency Check · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7561794
19 April 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7178239
7 August 2020 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7024617
13 May 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5870345
13 December 2011 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4207201
13 December 2011 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4207233
12 December 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4204398
17 October 2010 PII Safety Exam · MARPOL Annex VI Survey · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3870054
12 October 2010 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3946578
19 January 2010 PII Safety Exam · ISPS I Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3658298
12 January 2010 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 3658610
17 June 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3240603
17 June 2008 ISPS I Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3240679
13 June 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3235880
3 March 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3157405
25 February 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3153229
4 August 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2732391
2 August 2006 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2733856
3 June 2005 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2378062
2 June 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2377451

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 September 2023 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed F/O leak from #2 cylinder on #2 A/E 74SOLAS(09)II-2/4.1.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2023
Resolution: Received Class Report attesting to repairs
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 September 2023 Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed water leaking from packing gland of main fire pump. 74SOLAS(09)II-2/14.2.1.2 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 September 2023
Resolution: Received Class Report attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 19 September 2023 No resolution recorded
The boilers and associated piping systems and fittings shall be of a design and construction adequate for the service of which they are intended and shall be installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed steam leaking from sight glass on boiler. 74SOLAS(04)II-1/26.1 50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 September 2023 Resolved
Guard rails or bulwarks shall be fitted around all exposed decks. PSCO observed 03 broken guard rails on the starboard side by cargo hold 1 and 4 and 01 broken guard rails on the port side by cargo hold 1. ICLL(88Prot)Reg25(2) 16AC
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2023
Resolution: Received Class Report attesting to repairs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 September 2023 Resolved
The rings, lines and letter shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed deck line painted black on a dark ground. ICLL(88Prot)Reg8 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
Resolution: Crew repainted deck line while PSCO was on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2023 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service of which they are intended. PSCO observed excessive leakage of M/E jacket cooling water from cooling water line going to M/E cylinder #3.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 September 2023
Resolution: Crew tightened leaking fittings after they were identified.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 19 September 2022 Resolved
Every steam pipe and every fitting connected there to through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be ;subjected. PSCO obeserved steam leaking from the following but not limited to: #1 Safety Relief Valve bottom gasket, steam tracing line bottom level engine room starboard aft, steam tracing level main engine intermediate platform, and the steam tracing line valve for fuel oil settling tank. 74 SOLAS (2004) II-1/33.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2022
Resolved 27 September 2022
Resolution: Class report provided in documents rectified deficiency to the satisfation of the Coast Guard and Class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2022 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI/1, or with applicable national standards of the Administration which provide an equivalent level of safety. PSCO observed the soft patches and temporary repair including but not limited to: fire main engine room lower level, seawater cooling lines for freshwater generator, seawater cooling for generators, piping at bottom level of engine room near emergency escape. 74 SOLAS (2004) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 September 2022
Resolved 30 January 2023
Resolution: Permanent repairs completed on affected piping.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 September 2022 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed the reservoir for the vessel quick closing valves in the fire control station was leaking air and pressure gauge was below the level indicated for operation. 74 SOLAS (2020) II-2/14.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2022
Resolved 27 September 2022
Resolution: Class report provided in the attachments rectified deficiency to the satisfaction of class and Coast Guard.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 19 September 2022 Resolved
No person may operate any vessel equipped with an installed toilet facilities unless it is equipped with an operable type II marine sanitation device. Vessel is equipped with a Taikokikai Industries type II MSD approval no. 159.015/3229/0. Sewage aeration blower inoperable. Requisition no. E 37-2022 was raised on 08 April 2022, but has not been supplied onboard to date.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 September 2022
Resolved 30 January 2023
Resolution: New sewage aeration blower installed.
Communications › Radio Communications › EPIRB
Issued 12 December 2011 Resolved
Every ship shall be provided with a satellite emergency position indicating radio beacon (EPIRB.) EPIRB is not emitting any signal. Chief Mate indicated battery is dead.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2011
Resolution: M/V MAPLE CREEK Crew replaced inoperable EPIRB and installed in float free arangment.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 12 October 2010 Resolved
Vessel was discovered in port at Red Dog Mine, AK without a valid NOA.
Action required: 705 - Other - as specified
Resolved 14 October 2010
Resolution: Vessel submitted a valid NOA.
Lifesaving › Launching Appliances › Release Mechanism
Issued 19 January 2010 Resolved
The hook holding the aft gripe on the starboard life boat/rescue boat to the aft davit is stuck in place. During test lowering of the life boat during PSC exam the hook did not release the gripe, which caused the gripe to snap. In this condition the life boat/rescue boat cannot be stowed in a state of continuous readiness.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 January 2010
Resolution: Attended vessel to verify repair of aft gripe hook for starboard side life boat/rescue boat. Gripe was verified repaired by crew and life boat was lowered, raised, and stowed properly for sea three times.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 3 March 2008 Resolved
01 Firefighting suit worn through between the legs, compromising fire protection to crew member. 17a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 March 2008
Resolution: Received Class report, stating, "The following new fire fighter''''s outfit was provided instead of the damaged suit and it was found satisfactory." Viking Life-Saving Equipment A/S: A, B1, C3 - EN531
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 3 March 2008 Resolved
Previous conditions of class were not cleared, and no corrective action were taken by the specified date required. 16a
Action required: 705 - Other - as specified
Due 17 March 2008
Resolved 4 March 2008
Resolution: Received completed Corrective Action Plan from Class surveyor, which had been approved by the due date. Since the vessel''s Captain was unable to produce this information during the course of the exam, this deficiency is hereby cleared, but not rescinded.

Ownership record