IKAN BILIS is a freight ship. The Coast Guard has recorded 11 inspections since 2005, most recently in July 2016, along with 6 deficiencies and 3 operational controls.

Records from 2005 to 2016. Most recent: inspection, 24 July 2016.

Built
Not recorded
Last inspected
24 July 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9279525 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V7556
753556
Flag
SINGAPORE
—
Maury page id
psix-753556

Inspections, by type

…with no type recorded4
Years with a record 6 calendar years (2005–2016)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38871 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

24 July 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5950882
21 June 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4341590
18 October 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3864730
13 February 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3413360
13 February 2009 Ballast Water Examination · NPV Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3421214
28 January 2009 ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3401545
28 January 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3401735
12 March 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3163442
8 December 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2548383
3 June 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2374787
3 June 2005 ISPS I Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2378593

Deficiency record · 6

Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 24 July 2016 Resolved
Each incenerator subject to this paragraph shall be approved by the Administration taking into accout the standard specification for the shipboard incenerators developed by the organization. As per MEPC.76(40), incinerator walls are to be protected with insulated fire bricks. Insulated fire bricks on incenerator door were completely destroyed, and door gasket was missing. MARPOL Annex VI/16.6.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2016
Resolved 26 July 2016
Resolution: PSC HOU-GAL received a class survey from NKK attesting that the operation of the ship's incinerator is safe in its current condition after a new door gasket and fire protected bricks with insulation were installed by the ships crew.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 18 October 2010 Resolved
1575- SOLAS 2001 Con. Ed. CH. V Reg 12(k) 17(c) Vessels electronic depth sounding device was inoperable during the Port State Control Exam. Vessel is required to have a proper working electronic depth sounding device.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2010
Resolution: Received tech report stating, " (B) Found Sounder to be in need of cleaning. (C) Started up sounder and found to now be working normally." A scanned copy of the tech report has been added to the activity.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 October 2010 Resolved
1499 - SOLAS 2001 Con. Ed. Ch. I Reg 11(a) 50(a) Auxiliary salt water cooling pipe holed and temporary repaired. Hole located at first elbow above the "T" after pumps.
Action required: 705 - Other - as specified
Due 17 November 2010
Resolved 21 June 2012
Resolution: Reviewed class report attesting to satisfactory repairs, and visually inspected.
Electrical › Electric Generation Source (service) › Generator
Issued 6 February 2009 Resolved
#2 AND #3 SSDG have temporary fiberglass patches on the salt water cooling supply lines that have not been reported to Company as required. SOLAS 2004 IX/5 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 13 March 2009
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 6 February 2009 Resolved
Bearing failure on #6 cargo hold hach cover (port side) was repaired by contractors. Vessel must provide watertight integrity NKK Class report SOLAS 2004I/11 17a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2009
Resolution: Received Class report attesting to repair of No. 6 hatch covers. Tested weather tightness by hose test at 0.2 MPa, found satisfactory.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 12 March 2008 Resolved
Hydrostatic releases on vessels port and starboard life rafts improperly connected, painter not secured to the weak link, rendering undue safety hazard to crew.
Condition: Improper Installation
Due 20 March 2008
Resolved 20 March 2008
Resolution: Deficiency rectified to satisfaction of the Coast Guard.