MAURY USCG vessel records Sign in
← All vessels

EVROS

EVROS is a 2005 tank ship. The Coast Guard has recorded 3 inspections in 2005, along with 2 deficiencies and 2 operational controls.

Records in 2005. Most recent: inspection, 14 September 2005.

Built
2005
Last inspected
14 September 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9290921 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
754183
Flag
GREECE
—
Maury page id
psix-754183

Inspections, by type

Years with a record 1 calendar year (2005)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12196 - Convention (Subpart B), Net Ton
12196 - Regulatory (Subpart C or D), Net Ton
30020 - Convention (Subpart B), Gross Ton
30020 - Regulatory (Subpart C or D), Gross Ton
47119 - Dead Weight, Ton
57625 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

14 September 2005 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2492184
22 June 2005 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2399582
2 June 2005 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2373078

Deficiency record · 2

Engineering › Electric Propulsion System › Remote Control Circutry
Issued 19 June 2005 Resolved
Issued vessel Letter of Deviation #17-2005 granting vessel a one-time deviation for loss of remote control for MDE propulsion system to enter the Sabine Neches waterway. Permanent repairs shall be made prior to vessel's departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2005
Resolution: Received faxed technician''s report from Radio Holland USA stating that the vessel''s remote control for the MDE propulsion system was operational.
Deck/Cargo › Cargo Heating › General
Issued 2 June 2005 Resolved
Make repairs to leaking tank cleaning heater solenoid valve in the mid ship house.
Due 2 July 2005
Resolved 14 September 2005
Resolution: Rcvd a letter from the manufacture stating that the valve is working in a manner in which it was designed.

Ownership record