99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 October 2025
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. 120 volt panel in the FWD Engine Room not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 20 November 2025
Resolution: Panel labeled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2025
Resolved
Pressure vessels must be externally examined annually. Relief valves must be tested in accordance with 46 CFR 143.245. Each towing vessel must perform the applicable testes in Table 143.245(b): Pressure relief valves - twice every 5 years, with no more than 3 years elapsing since the last test. Pressure relief valves not tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 20 November 2025
Resolution: Pressure relief valve tested/tagged.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 October 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Dead end wire discovered centerline FWD Engine room in front of "warning" sign. Remove cable.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 20 November 2025
Resolution: Cable removed from E/R and junction box.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 October 2025
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards... 02 portable fire extinguishers not properly mounted in the Engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 20 November 2025
Resolution: Ext. Mounted in upper level E/R with proper bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 October 2025
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in table 141.370 for specified areas where the vessel operates: 3 Day, 3 Night. Distress signals found expired. Replace with new.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 20 November 2025
Resolution: Flares replaced: EXP SEP2028
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 October 2025
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating condition. First aid kit (Aft) found inadequate for operation. Replace with new.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 20 November 2025
Resolution: First aid kit replaced with new.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 October 2025
Resolved
Fire Detection Requirements: The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, by a technician with qualifications as a National Institute for Certification in the Engineering Technologies (NICET) level IV fire alarm engineering technician, or by an authorized classification society with equivalent experience to comply with paragraphs (a)(1) through (7) of this paragraph. Fire detection panel found not serviced or tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 10 November 2025
Resolution: Annual service conducted on fire detection panel, and heat sensors. Report added to documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 October 2025
Resolved
... be marked in block capital letters with the name of the vessel... Stbd Pilot [name withheld] ring buoy found not labeled. Properly label with vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025
Resolved 20 November 2025
Resolution: Life ring properly labeled with vsl name.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 October 2025
No resolution recorded
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel:(1) Personnel records, in accordance with § 140.400;(2) Safety orientation, in accordance with § 140.410;(3) Record of drills and instruction, in accordance with § 140.420;(4) Examinations and tests, in accordance with § 140.615;(5) Operative navigational safety equipment, in accordance with § 140.620;(6) Navigation assessment, in accordance with § 140.635;(7) Navigation safety training, in accordance with § 140.645;(8) Oil residue discharges and disposals, in accordance with § 140.655;(9) Record of inspection of towing gear, in accordance with § 140.820; and(10) Fire-detection and fixed fire-extinguishing, in accordance with § 142.240. Master log, training/drill log, equipment log not improperly logged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2025 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 October 2025
No resolution recorded
The following alarms must be provided:(1) Main engine low lubricating oil pressure;(2) Main engine high cooling water temperature;(3) Auxiliary generator engine low lubricating oil pressure;(4) Auxiliary generator engine high cooling water temperature;(5) High bilge levels;(6) Low hydraulic steering fluid levels...Alarms must:(1) Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at Operating Station... Timco monitoring system for engine room equipment is not properly displaying correctly, and not clearing e/r alarms while engines are running.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2025 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 October 2024
Resolved
Each window or port light, and its means of attachment to the hull or the deck house, must be capable of withstanding the maximum expected load from wind and waves, due to its location on the vessel and the vessel's authorized route. STBD E/R window was found broken. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 31 March 2025
Resolution: STBD E/R window replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2024
Resolved
Cable hangers for overhead and vertical cable runs must be installed with metal supports and retention devices at least every 48 inches. Plastic zip ties were found in the E/R supporting horizontal and vertical cable runs. Replace with metallic hangers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2024
Resolved 31 March 2025
Resolution: Metallic Hangers installed in E/R.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 July 2022
Resolved
Vessel had onboard prescribed safety orientation for crew and non-crew. However, the document was blank. Review and fill prescribed safety orientation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 17 August 2022
Resolution: Crew completed orientation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 July 2022
Resolved
Vessel is to have onboard a current COD. Vessel does not have onboard a current COD.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2022
Resolved 21 July 2022
Resolution: Vessel provided copy of COD recently aquired from NVDC.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 July 2022
Resolved
Vessel has void spaces with watertight hatches. Hatches do not tighten properly and have potential to allow water inside the voids.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2022
Resolved 24 August 2022
Resolution: New watertight gaskets were installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 July 2022
Resolved
Vessel is to have a low level hydraulic steering alarm that sounds in the operating station. Vessel does not have low level alarm that sounds in the operating station.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 17 August 2022
Resolution: Sensor installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 July 2022
Resolved
Vessel is to have emergency lighting for areas where the vessel's crew transits during operation. Vessel to install prescribed emergency lighting.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 2 August 2022
Resolution: Installed emergency lights.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 July 2022
Resolved
Vessel is to have an approved 160-B semi portable of fixed fire-extinguishing system to protect the engine room. Vessel to replace the on board B-V extinguisher with an approved 160-B semi portable fire-extinguisher or equivalent.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 2 August 2022
Resolved 2 August 2022
Resolution: Vessel purchased 160-B dry chem extinguisher.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 July 2022
Resolved
Vessel is to have insulated exhaust manifolds and turbochargers. Vessel does not have prescribed insulation on both diesel generators.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2022
Resolved 17 August 2022
Resolution: Insulation was installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2022
Resolved
All owners and operators of an existing towing vessel must have onboard a valid COI prior to the specified phase-in period. This vessel has not scheduled an inspection or obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection immediately and the vessel may no longer be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 August 2022
Resolution: COI Inspection complete. COI issued.