Inspection record

Last inspected 23 December 2024
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9298703
754778
Flag
CANADA
Maury page id
psix-754778

Documentation record

Tonnage as PSIX records it10119 - Convention (Subpart B), Net Ton
459714 - Displacement, Ton
37515 - Dead Weight, Ton
23356 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

26 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 26

23 December 2024 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8049139
16 December 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7837863
6 November 2022 COC-CHEM & TVE Annual · Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7589706
6 December 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7363108
8 November 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7346679
23 April 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7181212
22 March 2021 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7160512
3 November 2020 Ballast Water Examination · COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7086966
12 November 2019 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6853619
28 July 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6768264
3 December 2018 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6591060
31 October 2018 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6569676
21 March 2018 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6376457
10 February 2018 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6353031
24 November 2017 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6313089
23 October 2017 Ballast Water Examination · COC-CHEM & TVE Renew · MARPOL Annex I Examination · MARPOL Annex V Examination · MARPOL Annex VI Survey · ISPS II Exam · PII Safety Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6290792
3 June 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6170585
29 May 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6159201
29 May 2017 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6214067
8 May 2017 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6141530
6 May 2017 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6141205
3 May 2017 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6137983
21 November 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6044931
9 May 2016 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5872231
12 April 2016 PI Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5852521
12 April 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5854720

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 December 2023 Resolved
For tankers of > 20,000 DWT, the protection of cargo tanks shall be achieved by a fixed inert gas system IAW the requirements of the FSS Code. The inert gas system shall be designed to be capable of rendering and maintaining the atmosphere of the relevant cargo tanks non-flammable. PSCO observed that the span gas bottle used to calibrate the IGG system did not have a certificate validating its expiration date. Vessel must provide class report to CG showing that new span installation/certification and the IGG system calibration for that bottle. 74 SOLAS (14) II-2/4.5.5 FSS Code 15.2.2.1.1
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 December 2023
Resolution: Submitted satisfactory Class report
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 8 November 2021 Resolved
07102: A water seal. if fitted. shall be capable of being supplied by two separate pumps, each of which shall be capable of maintaining an adequate supply at all times. While on deck, PSCO went to check the visual level of water on the deck water seal. The water level cannot currently be seen as the sight glass needs to be replaced. SOLAS2004(cons.) II-2/10.7.2 FSS 15.2.2.3.1.4 50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 6 December 2021
Resolution: Master sent photos of repaired deck seal sight glass and notified Class that repairs were complete.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 November 2019 Resolved
001-0720-Multiple rubber style fire hoses failed during the fire drill. Significant leaks found along the hose lenths. Hoses are no longer servicable. Ships shall be provided with fire hoses, the number and dianeter of which shall be to the satisfaction of the administration.-Solas Chapt. II-2 Reg 10.2.3.2.1-17AC
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2019
Resolved 15 November 2019
Resolution: Vessel recieved new approved fire hoses with documentation.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 31 October 2018 Resolved
1860- Personal Protection- 50ac Decontamination showers and eyewash shall be operable in all ambient conditions. Showers and eyewash stations on deck were inoperable. IBC (2016) 14.3.4
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2018
Resolved 3 December 2018
Resolution: The practice of shutting and draining of decontamination showers be stopped. Showers will be maintained in a fully functional condition throughout winter months, with heated circulation water being maintained on the system.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Cylinder
Issued 29 May 2017 Resolved
Main and auxiliary machinery essential for propulsion and safety of the ship shall be provided with effective means for its operation and control. Number 6 main engine cylinder is not operational causing a degradation in propulsion.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2017
Resolved 5 June 2017
Resolution: Received class report attesting to the repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 12 April 2016 Resolved
Means of going astern-Ability to reverse direction of thrust. Ship engineering controls unable to engage in reverse propulsion due to material failure in reversing air cylinder.
Condition: Design Flaw
Due 12 April 2016
Resolved 13 April 2016
Resolution: Lloyds register issued class certificate attesting to proper operation of M/E.