PRIORITY C is a 2004 tank ship. The Coast Guard has recorded 17 inspections since 2018, most recently in September 2023, along with 2 deficiencies and 5 operational controls.
Records from 2018 to 2023. Most recent: inspection, 12 September 2023.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it28245 - Convention (Subpart B), Gross Ton 12822 - Convention (Subpart B), Net Ton 55682 - Displacement, Ton 46847 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; 5 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 17
12 September 2023PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7790023
23 June 2022PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7484205
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 7 September 2018Resolved
14199 - Other (MARPOL Annex I) - The system shall be fitted with a recording device... this record shall be identifiable as to time and date and shall be kept for at least three years. Port State Control Officers found the ODME records do not show the correct date. - MARPOL Annex I/31.2
Action required: 10 - Deficiency Rectified
Due 7 September 2018
Resolved 7 September 2018
Resolution: CG witnessed the [name withheld] adjust the date so that the new printouts now have the correct date.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 7 September 2018Resolved
14105 - Pumping, piping and discharge arrangements - In considering the design of such equipment and approvals, the Administration shall have regard to the specification recommended by the organization. Re-circulating facilities should be provided, after and adjacent to the overboard outlet... to be tested with the overboard discharge closed. Port State Control Officers found that the OWS cannot recirculate with the overboard discharge closed. - MARPOL Annex I/14.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2018
Resolved 17 September 2018
Resolution: See attached. ABS changed and stamped the vessels OWS drawing, and verified the changes proposed were made. New IOPP certificate was issued.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.