CHEM 282 is a 2005 tank barge. The Coast Guard has recorded 24 inspections since 2005, most recently in March 2022, along with 2 deficiencies.

Records from 2005 to 2022. Most recent: inspection, 24 March 2022.

Built
2005
Last inspected
24 March 2022
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 24 March 2022
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 16 calendar years (2005–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

755941
Flag
UNITED STATES
Maury page id
psix-755941

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2005
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portJEFFERSONVILLE, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

24 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

24 March 2022 MTSA Verification · COI Inspection · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7412128
10 July 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7002647
11 September 2018 MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6537723
14 July 2017 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6237455
9 June 2016 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5921417
14 July 2015 COI Inspection · Internal Structural Exam · MTSA Verification · Cargo Tank Internal · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5179960
15 July 2014 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4930556
15 July 2014 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4940938
18 July 2013 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4654271
10 September 2012 Annual Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4439830
21 September 2011 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4156967
14 July 2011 Type not recorded
No type recorded · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 4081976
12 November 2010 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3889817
7 September 2010 Examination of Repairs · Internal Structural Exam · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3832454
11 September 2009 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3593767
19 May 2009 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3478966
15 September 2008 Deficiency Check · Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3320828
1 August 2008 Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3305139
7 December 2007 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3126813
17 October 2007 Damage Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3081721
7 September 2007 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3051616
25 August 2006 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2759419
22 July 2005 Hull Examination · Internal Structural Exam · Cargo Tank Internal · MTSA Verification · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2435408
6 June 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2381752

Deficiency record · 2

Electrical › Electric Supply System (service) › Cable
Issued 1 August 2008 Resolved
Electronically controlled engine not in compliance with 46 CFR 111.105.31( l). Vessel operator given until 01JAN09 to correct IAW D8 policy guidance 01-2008 and their approved company compliance plan. ACL compliance plan and D8 compliance plan approval letter have been scanned into vessel documents. For additional information see CG Central/Communities/Domestic Vessel Inspections (Flag State
Action required: 705 - Other - as specified
Due 1 January 2009
Resolved 17 September 2008
Resolution: John Deere intrinsically safe ignition retro-fit system installed and test sat.
Construction/Loadline › Hull › Stiffener
Issued 17 October 2007 Resolved
After offloading current cargo of Methanol, proceed directly to a repair yard to effect permanent repairs to external tank stiffeners #5-9 on portside, damaged as a result of allision on 17OCT07. Contact local OCMI to schedule repair check prior to conducting further cargo ops.
Action required: 705 - Other - as specified
Due 31 December 2007
Resolved 7 December 2007
Resolution: Proper permanent repair was made to portside stiffeners #5-9.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.