← All vessels
COMET
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northeast District (CGD-NE) · Other hulls named COMET
COMET is a 2005 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2005, most recently in May 2026, along with 21 deficiencies.
Records from 2005 to 2026. Most recent: inspection, 4 May 2026.
- Built
- 2005
- Last inspected
- 4 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 21 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded1
Years with a record
19 calendar years (2005–2026)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it4 - Simplified, Gross Ton
3 - Simplified, Net Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
4 May 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8361242
29 April 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087837
18 March 2025
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087826
23 April 2024
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7891775
18 April 2023
Internal Structural Exam · Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7664054
26 April 2022
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7430354
28 April 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7166367
16 April 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7166369
28 May 2020
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6951499
30 April 2019
Drydock Exam · DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6664392
4 June 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6420359
2 May 2017
Annual Inspection · Internal Structural Exam · DAPI Audit · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6134450
4 May 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5862821
27 August 2015
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5227782
27 August 2015
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5227994
2 May 2014
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4848861
3 May 2012
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4278842
11 May 2009
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3470478
13 May 2008
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3171167
24 May 2007
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2938459
14 March 2007
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2887991
24 May 2006
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2628412
9 June 2005
Initial Certification · Construction Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2384454
Deficiency record · 21
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 May 2026
Resolved
A vessel of not more than 7.9 meters (26 feet) in length must carry a minimum of one life buoy of not less than 510 millimeters (20 inches) in diameter. Ring life buoy was deteriorated and requires replacement.
46 CFR 180.70(a)(1)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2023
Resolved
At each inspection, each portable fire extinguisher shall be checked for excessive corrosion and general condition. Fire extinguisher has corrosion on top at the handle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2023
Resolved
Equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Fuel filter assembly must be cleaned out.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 28 April 2021
Resolved
Master did not possess medical certificate during inspection. Provide evidence of medical certificate to CG marine inspector.
Documentation › Logs/Records › Logbook (official)
Issued 28 August 2015
Resolved
Vessel did not have a logbook for the recording of training and drills. Provide new logbook to record aforementioned.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 28 August 2015
Resolved
Vsl missimg Emergency instruction list, post new emergency instruction list.
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 August 2015
Resolved
Vsl's lifejacket donning placard was no longer permanently affixed, reaffix placard.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 28 August 2015
Resolved
Rep. did not have a means of providing a passenger count list. Provide a means to record passenger count.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 August 2015
Resolved
Vessel overdue for Annual, Drydock, and Internal Structural exams. Conduct Annual, Drydock, and Internal Structural exams prior to carrying passengers.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2014
Resolved
Replace expired medications.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 May 2014
Resolved
Replace water light battery.
Fire Fighting › Fire Bucket › Quantity
Issued 2 May 2014
Resolved
Provide 1 additional fire bucket
Engineering › Bilge Water Management System › Pump
Issued 2 May 2014
Resolved
Provide operational bilge pump activation indicator light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2009
Resolved
No first aid kit was available.
Lifesaving › Hand Flares › Not on Board
Issued 11 May 2009
Resolved
Required flares were not present
Documentation › Markings/Placards › Garbage Placard
Issued 11 May 2009
Resolved
Garbage Placard Not Posted
Fire Fighting › Ventilation Systems › Ducts
Issued 11 May 2009
Resolved
Provide vent closure for E/R compartment prior to carrying more then 6 passengers
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 May 2009
Resolved
Complete fire system inspections prior to carrying more then 6 passengers
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 May 2009
Resolved
Provide proper battery for ring buoy water light. Restricted to day light ops only
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 May 2009
Resolved
Prior to carrying passengers prove proper enrollment in a random drug testing program
Engineering › Bilge Water Management System › Valve
Issued 14 March 2007
Resolved
Vessel is required to have a positive shut off valve at the hull penetration. (46CFR182.520)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.